Digital Panel Meter Selection Guide
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 1. |
DC Digital Panel Meter Exceptional accuracy and high read rate with five digital voltmeter ranges from 200.00 mV to ±300.0 V and four digital ammeter ranges from ±2.0000 mA to ±5.000 A, all factory pre-calibrated. Shipped ready to run. |
|
| 2. |
True AC RMS Panel Meter Five AC RMS voltmeter ranges to 200.00 mV to 600.0 V and four AC RMS ammeter ranges from 2.0000 mA to 5.000 A, all factory pre-calibrated. Shipped ready to run. |
|
| 3. |
Process & Strain Meter
User-scalable for display to ±99,999 for process signals
requiring zero and span adjustment, such as 0-1 mA, 4-20 mA,
or 0-10 V. Ideal for use as a readout for pressure
transducers (manometer applications) and flow meters.
Includes 5, 10, 24 V transducer excitation output
(user-selectable). |
|
| 4. |
Process Meter & Totalizer User-scalable for display to ±999,999 for 0-1 mA, 4-20 mA, or 0-10 V process signals requiring zero and span adjustment. Ideal as flow rate meter or flow totalizer for analog flow meter signals. Includes 5, 10, 24 V transducer excitation output (user-selectable). |
|
| 5. |
Load Cell & Microvolt Meter A high-sensitivity 5-digit meter for use with load cells, strain gauges and microvolt input signals where high accuracy and stability are required. Load cell operation allows 4- or 6-wire hookup and display in engineering units, such as lbs, kg or psi. Built-in excitation for up to four 350-ohm load cells in parallel. |
![]() |
| 6. |
Scale / Weight Meter Equipped with a DC or load cell signal conditioner, this Laureate offers special firmware for scale / weighing applications: two tare functions; count by 1, 2, 5, 10, 20, 50 or 100; auto-zero function; setpoint offset, and dummy right-hand zero for display to 999,990. Built-in excitation for up to four 350-ohm load cells in parallel. |
![]() |
| 7. |
Thermocouple Temperature Meter High accuracy in one instrument for seven thermocouple types (J, K, T, E, N, S, R), each in one range. User-selectable thermocouple type, °C or °F, and 1° or 0.1° resolution. Pre-calibrated for all sensor types. Wide range of options for communication and temperature control. Shipped ready to run. |
![]() |
| 8. |
RTD Temperature Meter Exceptional accuracy RTD temperature meter for Pt100 100-ohm platinum RTDs (DIN or ANSI alpha), Ni120 nickel and Cu10 copper. User selectable RTD type, unit of measure (°F or °C) resolution (1° , 0.1° or 0.01°), and 2, 3 or 4-wire hookup to eliminate lead resistance effects. Pre-calibrated for all RTD types. Wide range of options for communication and temperature control. Shipped ready to run. |
![]() |
| 9. |
Ohmmeter Factory calibrated for five jumper selectable resistance ranges from 20 Ω to 200 KΩ. Exceptional accuracy of ±0.01% of full scale. In the 20-ohm range, resolution is 1 milliohm, making the meter suitable for contact resistance measurements. 2, 3 or 4 wire connection to eliminate lead resistance effects. |
![]() |
| 10. |
Linearizing Panel Meter
All capabilities of the Laureate process meter, plus custom
curve linearization.
Setup is easy using an external PC and linearizing software
furnished by Laurel. For example, display liquid
volume in irregularly shaped tanks, use with non-linear
transducers, or extend the working range of nominally linear
transducers. |
|
| 11. |
88-PRO Loop-Powered Digital Panel Meter Scalable process meter powered by 4-20 mA, 10-50 mA or 1-5 mA current loop, with no need for external power. 12.7 mm (0.50") high LCD digits, 1/8 DIN case. |
|
| 12. |
Junior Series Digital Panel Meter Low-cost, screwdriver-adjusted 3 1/2 digit indicators for process signals (4-20 mA, 1-5 V, etc.), DC, AC avg, and AC rms (voltage & current). No control outputs.14.2 mm (0.56") high digits, 1/8 DIN case. |
|
| 13. |
M-35 Microminiature Digital Process Meter Fits 22.5 x 45 mm cutout. Accepts 4-20 mA, 0-10 mA, 0-2 V, 1-5 V, or 0-10 V signals. Powered from 10-30 Vdc. |
|
![]() |
||
| 14. |
Grand Series 2", 4", 6" or 8"
Large-Digit Displays Available with five 57 mm (2.2"), 102 mm (4.0"), 144 mm (5.7"), or 200 mm (7.9") high digits for process signal, strain gauge or load cell inputs. RS-422 and dual-relay output options. |
![]()
|
|||
| Laureate Options | Laureate Downloadable Files | ||
|
|||
| Laureate Mechanical Specs | |||
|
|||
|