Laureate™ Duty Cycle Meter
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() |
|
|
![]() |
![]() |
![]()
Features
|
![]()
Description
Duty Cycle Mode
Universal Signal Conditioner
Other Features & Options
|
![]()
Specifications
| Duty Cycle Mode | |
| Item Displayed Display Units Frequency Range Accuracy Maximum Timing Interval |
ON
or OFF duty cycle of periodic pulse waveshape |
| Display | |
| Readout Range Indicators |
6 LED digits, 7-segment, 14.2 mm (.56"), red
or green -999999 to +999999 Four LED lamps |
| Inputs | |
| Types Signal Ground Minimum Signal Maximum Signal Maximum Frequency Contact Debounce |
AC,
pulses from NPN, PNP transistors, contact closures, magnetic pickups. |
| Update Rate | |
|
Conversion
Interval Gate Time Time Before Zero Output |
Gate
time + 30 ms + 0-2 signal periods |
| Power | |
| Voltage, standard Voltage, optional Frequency Power Isolation |
95-240 Vac ±10% or 90-300 Vdc 12-30 Vac or 10-48 Vdc DC or 47-63 Hz 250V rms working, 2.3 kV rms per 1 min test |
| Excitation Output | |
| 5
Vdc 10 Vdc 24 Vdc Output Isolation |
5 Vdc ±5%, 100 mA 10 Vdc ±5%, 120 mA 24 Vdc ±5%, 50 mA 50 Vdc to meter ground |
| Analog Output (optional) | |
| Output
levels Compliance Scaling Resolution Isolation |
0-10V,
0-20 mA, 4-20 mA (jumper selectable) 2 mA at 10V (5 kOhm load), 12V at 20 mA (0-60 ohm load) Zero and full scale adjustable from -99999 to +99999 12 bits (0.025% of full scale) 250V rms working, 2.3 kV rms per 1 min test |
| Dual Contact Relay Outputs (optional) | |
| Relay
Type Load Rating Isolation |
Form C 8A at 250 Vac or 24 Vdc 250V rms working, 2.3 kV rms per 1 min test |
| Dual Solid State Relay Outputs (optional) | |
|
Relay Type Load Rating Isolation |
SPST, normally open,
Form A 120 mA at 130 Vac or 170 Vdc, 28 ohms series resistance. 250V rms working, 2.3 kV rms per 1 min test |
| Serial Data I/O (optional) | |
|
Board Selections Protocols Data Rates Digital Addresses Isolation |
RS232, RS485, Modbus RS485 Modbus RTU, Modbus ASCII, simpler Laurel ASCII 300 to 19200 bps 247 (Modbus), 31 (Laurel ASCII), 250V rms working, 2.3 kV rms per 1 min test |
| Environmental | |
| Operating
Temperature Storage Temperature Relative Humidity Protection |
0°C
to 60°C -40°C to 85°C 95% at 40°C, non-condensing NEMA-4X (IP-65) when panel mounted |
| Signal Connections | |
![]() |
|
![]()
| Applications | |
Duty Cycle Mode |
|
![]() |
Duty cycle indicates the ON or OFF time in percent from 0% to 100% of period for repetitive pulse train. In the illustration, duty cycle is 100 x t/P. The same signal is applied to the A and B channels. |
Duty Cycle and Elapsed Time of a Laser |
|
![]() |
Duty cycle can be used to indicate the ON time of a pulsed laser in relation to total time. Laureate counters can also measure elapsed time, the number of pulses, average width in µs, the number of pulses, and total energy applied. |
![]()
Ordering
Guide
Laureate Duty Cycle Meter
| Create a model
number in this format: L60101FR. This example calls out a Laureate
counter with an Extended Main Board with red LEDs, 95-240 Vac ±10% &
90-300 Vdc
power, dual 8A contact relays, no second output, RS-232 serial output,
and a dual-channel frequency signal conditioner. Includes plug-in screw
terminals. |
|
Main Board |
L7 Extended Main Board, Green LEDs. L8 Extended Main Board, Red LEDs. |
$270 $270 |
||
| Note: Use of the Extended Main Board makes this counter also suitable for A-B time interval, stopwatch, frequency, rate, period, square root of rate, up or down total, arithmetic functions, simultaneous rate and total, phase angle, batching, and custom curve linearization. | ||||
| Power |
0 Isolated 95-240 Vac ±10% & 90-300 Vdc 1 Isolated 12-30 Vac & 10-48 Vdc. |
NC $30 |
||
|
Setpoint Output |
0 None. 1 Dual 8A Contact Relays. 2 Isolated Dual Solid State Relays. |
NC $80 $55 |
||
|
Analog Output |
0 None. 1 Isolated 0-20 mA & 0-10 V. |
NC $90 |
||
|
Digital Interface |
0 None. 1 Isolated RS-232. 2 Isolated RS-485. 4 Isolated Modbus RS-485. |
NC $60 $80 $90 |
||
|
Input Type |
FR Dual-Channel Pulse Input Signal Conditioner | NC | ||
|
Add-on Options |
|
$30 NC $19 $39 $40 $140 $180 |
|
Resource Pages |
|