 |
Laureate™ Power Options
For 95-240 Vac ±10% & 90-300 Vdc or
12-30 Vac &
10-48 Vdc Input
with 5, 10 & 24 Vdc Excitation Output

12-30 Vac & 10-48 Vdc power input board (left)
95-240 Vac ±10% & 90-300 Vdc power
input board (right) |
 |
 |
 |

Features
- Lightweight, high-frequency switching
power supply design.
- 95-240 Vac ±10% or 90-300 Vdc input
(standard):
Allows worldwide AC operation without hardware modification.
Includes 250 Vac, 0.1A resetable fuse.
- 12-30 Vac or 10-48 Vdc power
(optional):
Allows
operation from batteries, 28 Vac, or 400 Hz aircraft power.
- Three selectable isolated excitation
outputs:
5 Vdc at 100 mA, 10 Vdc at 120 mA, or 24 Vdc at 50 mA.
- Certified to UL 61010C-1 (UL mark), EN 61010-1 (CE mark),
and RoHS.
|

Description
Laureate digital panel meters, digital counters and 6-digit remote display offer a choice of
two high-frequency switching power supplies. These provide stable, isolated power for
instrument operation plus excitation outputs at a substantially reduced weight and over a
broader range of input voltages and power frequencies than conventional linear supplies.
High voltage AC or DC power.
The standard Laureate supply accepts power from 85 to 240 Vac
±10%, 47-63 Hz. This allows
the same meter to operate worldwide without modification. The supply also accepts 90 to
370 Vdc.
Low voltage AC or DC power.
An optional low voltage supply operates from 9 to 37 Vdc or 8 to 28 Vac, 47-63
Hz. This supply allows the Laureate to be powered from batteries or from 28 Vac, 400 Hz
aircraft power.
Isolated Excitation Output
Each power supply provides
three jumper-selectable, isolated excitation outputs: 5 Vdc at 100 mA, 10 Vdc at 120 mA,
or 24 Vdc at 50 mA. These outputs can be used to power external sensors, transmitters and
up to four 350 ohm load cells, thereby avoiding the need for an expensive external supply.
When powering a load cell or potentiometer, a
ratiometric operating mode can be selected, where the meter monitors the excitation supply
and removes the effects of voltage variation.
In addition to the isolated excitation output,
regulated 5 Vdc at up to 50 mA is brought out and can be used to power external logic.
Wiring of Excitation Output

Meter Transmitter |

Meter Transmitter |
| 4-wire, 4-20 mA
transmitter wiring |
2-wire 4-20 mA
transmitter wiring |
Both power supplies and their
connectors (standard) are designed to UL/IEC/CSA safety standards. The two Laureate power supplies also do double-duty by providing two
connector inputs (A & B) and a digital ground for signals such as meter hold, reset,
tare, etc. These signals do not affect power supply operation.
|

Specifications
|
Operating
Power |
Voltage (std)
Voltage (opt)
Frequency
Power consumption |
95-240 Vac ±10% or
90-300 Vdc
12-30 Vac or 10-48 Vdc
DC and 47-63 Hz
5.3 W max |
|
Excitation
Power Supply |
Selectable
outputs
Ripple
Isolation to power ground
Isolation to meter ground |
5 Vdc ±5%, 100 mA
10 Vdc ±5%, 120 mA
24 Vdc ±5%, 50 mA
50 mVp-p max
250V rms working, 2.3 kV rms per 1 min test.
50 Vp |
|
Pin
Assignments (power and digital
controls) |
|
 |
|