Process, Strain Gauge &
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Features
|
![]()
|
![]()
Description Laureate 4-20 mA output, process input transmitters provide six DC voltage ranges and four DC current ranges for use with a wide range of industrial transducers whose output requires zero and span adjustment. All ranges are factory calibrated and jumper selectable. The two most sensitive voltage ranges, 200 mV and 2V, provide a high input impedance of 1 Gohm to minimize the load on the voltage signal. With Laureate process transmitters as described in this web page, strain gauges with a 20 mV output can be internally scaled to display up to 10,000 counts, while outputs of 200 mV can be scaled to 99,999 counts. With Laureate load cell transmitters, strain gauges with a 20 mV output can be internally scaled to the full 99,999 counts. Laureate process input transmitters duplicate the performance and programmable features of their Laureate process digital panel meter counterparts. Features include exceptional accuracy at high read rate, and optional dual solid state relays for local alarm or control. The transmitters are housed in a DIN rail case that is only 22.5 mm (0.89") thick. Signal connections are via detachable screw terminal connectors. In addition to the 4-20 mA output that would typically be used for signal transmission in an industrial environment, a 0-10V analog output is selectable. Either output tracks an internal digital reading, which is accurate to within ±0.01% of full scale input and is scalable in software. Output resolution is set by a 12-bit (4096 step) ultralinear digital-to-analog converter (DAC). Overall process transmitter accuracy is set by the DAC to ±0.05% of output span. Output isolation from signal and power grounds is provided by a separate on-board transmitter power supply, thereby eliminating potential problems caused by ground loops. The supply can an drive 20 mA into a 500 ohm (or lower) load for 10V compliance, or 10V into 5K ohm (or higher) load for 2 mA compliance.Transmitter programming is via a three-terminal RS-232 port using Laurel's PC-based Instrument Setup Software. This software can be downloaded from this website at no charge. The required transmitter-to-PC interface cable is available from Laurel (P/N CBL03). |
![]()
Specifications
Laureate 4-20 mA Transmitters
Process, Strain Gauge &
Potentiometer Follower Input
| Analog Input | Range | Input Ohms |
|
Voltage |
200.00 mV 2.0000 V 20.000 V 200.00 V 600.0 V |
1 Gohm 1 Gohm 1 Mohm 1 Mohm 1 Mohm |
|
Current |
2.0000 mA 20.000 mA 200.00 mA 5.000 A |
100 ohms 10 ohms 1 ohm 0.01 ohm |
|
Input Resolution Update Rate, Max Max Applied Voltage Over-current Protection |
16 bits (65,536 steps) |
|
| Analog Output | ||
|
Output Levels Compliance, 4-20 mA Compliance, 0-10V Output Resolution Output Accuracy Output Isolation |
0-20 mA and 0-10 Vdc (selectable) 10V ( 0-500 ohm load ) 2 mA ( 5 kOhm load ) 12 bits (4,096 steps) ±0.05% of output span 250V rms working, 2.3 kV rms per 1 minute test |
|
| Transducer Excitation Output (standard) | ||
|
Jumper Selection 1 Jumper Selection 2 Jumper Selection 3 |
10V @ 60 mA, isolated to 50V from signal ground 5V @ 50 mA, isolated to 50V from signal ground 15V @ 60 mA, non-isolated |
|
| Dual Relay Output (optional) | ||
|
Relay Type Load rating |
Two solid state relays, SPST, normally open,
Form A 120 mA at 130 Vac or 170 Vdc, 28 ohms series resistance. |
|
| Power Input | ||
|
Standard power Low power option Frequency Power Isolation |
95-240V AC ±10% or 90-300V DC 12-30V AC or 10-48V DC DC or 47-63 Hz 250V rms working, 2.3 kV rms per 1 min test. |
|
| Mechanical | ||
|
Case Dimensions Case Mounting Electrical Connections |
120 x 101 x 22.5 mm 35 mm rail per DIN EN 50022 Detachable screw terminal connectors |
|
| Environmental | ||
|
Operating Temperature Storage Temperature Relative Humidity |
0°C to
70°C -40°C to 85°C 95% at 40°C, non-condensing |
|
![]()
Pinouts
4-Wire Process,
2-Wire Process, Strain Gauge Transmitter
(shown with optional dual relay output)
|
|
|
|
Strain Gauge Transmitter |
|
|
|
|
|
Externally Powered 4-Wire Process Transmitter |
2-Wire Process Transmitter |
![]()
Application Examples
![]() |
| Potentiometer Application |
Custom curve linearization
|
![]()
Ordering
Guide
Laureate 4-20 mA Transmitters
Process, Strain or Potentiometer Follower Input
| Create a model
number in this format: TA202P. This is for a
4-20 mA output transmitter, standard main board, 95-240
Vac power, isolated dual solid state relays, and a
process input signal with the factory default setting
0-200 mV in = 4-20 mA out. Includes plug-in screw terminal
connectors. |
|
Transmitter Type |
TA Laureate 4-20 mA Transmitter. | $235 |
| Main Board |
2 Standard Main Board. 4 Extended Main Board. Note: Extended allows custom curve linearization and rate from successive readings. Not applicable to temperature. |
NC $40 |
| Power |
0 95-240 Vac & 90-300 Vdc 1 12-30 Vac & 10-48 Vdc. |
NC $30 |
|
Setpoint Output |
0 None. 2 Isolated Dual Solid State Relays. |
NC $30 |
| Signal Input |
Process Signals
(e.g., 4-20 mA, 0-5 V) P Default Scaling. 0-200 mV in = 4-20 mA out. P1 Custom Scaling. In the write-in field of your invoice, specify min input, min reading; max input, max reading. |
NC $10 |
|
Strain Gage,
Potentiometer (4-wire ratio) SG Default Scaling. 0-200 mV = 0-100.00. SG1 Custom Scaling. In the write-in field of your invoice, specify min input, min reading; max input, max reading. |
NC $10 |
|
| Note: The same DC signal conditioner can be user configured for process, strain or potentiometer follower signals, as well as DC Volts or DC Amps. It is precalibrated in EEPROM for all DC Volt and DC Amp ranges listed for DC transmitters. | ||
| Accessories |
CBL03 RS-232 cable, TA to computer. CBL02 USB to RS-232 cable adapter. |
$19 $39 |
|