Stopwatch for Single Events
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Features
|
|
![]()
Description
Transmitter Output
East to Set Up and Install
|
![]()
Specifications
Laureate 4-20 mA Transmitters
Stopwatch for Single Events or Accumulated Events
| Pulse Input | |
|
Types |
AC,
pulses from NPN, PNP transistors, contact closures, magnetic pickups. |
| Analog Output | |
|
Output Levels Compliance, 4-20 mA Compliance, 0-10V Output Resolution Output Accuracy Output Update Rate Output Isolation |
4-20 mA and 0-10 Vdc (selectable) 10V ( 0-600 ohm load ) 2 mA ( 5 kOhm load ) 12 bits (4,096 steps) ±0.05% of output span Programmed gate time + 30 ms + 0-2 signal periods 250V rms working, 2.3 kV rms per 1 minute test |
| Transducer Excitation Output (standard) | |
|
Jumper Selection 1 Jumper Selection 2 Jumper Selection 3 |
10V @ 60 mA, isolated to 50V from signal ground 5V @ 50 mA, isolated to 50V from signal ground 15V @ 60 mA, non-isolated |
| Dual Relay Output (optional) | |
|
Relay Type Load rating |
Two solid state relays, SPST, normally open,
Form A 120 mA at 130 Vac or 170 Vdc, 28 ohms series resistance. |
| Power Input | |
|
Standard power Low power option Frequency Power Isolation |
95-240V AC ±10% or 90-300V DC 12-30V AC or 10-48V DC DC or 47-63 Hz 250V rms working, 2.3 kV rms per 1 min test. |
| Mechanical | |
|
Case Dimensions Case Mounting Electrical Connections |
120 x 101 x 22.5 mm 35 mm rail per DIN EN 50022 Detachable screw clamp plug connectors |
| Environmental | |
|
Operating Temperature Storage Temperature Relative Humidity |
0°C to
70°C -40°C to 85°C 95% at 40°C, non-condensing |
![]()
| Typical Applications | |
Stopwatch Mode |
|
![]() |
The stopwatch mode is used to time single events between start and stop pulses on the same channel. Duration of a single wave shape can be measured by tying the A and B channels together. |
Timing Process Dynamics |
|
![]() |
The start and stop pulses used for timing can be generated by the dual relays in a Laureate panel meter, counter, or transmitter. For instance, the start and stop pulse edges can be created as temperature passes two alarm setpoints, or as temperature cycles in a hysteresis control mode. |
Replacing an Oscilloscope with a Laureate Meter or Transmitter |
|
|
An oscilloscope is great for viewing and timing pulses in a lab. However, in fixed installations where digital timing accuracy and control outputs are required, a low-cost Laureate time interval meter or transmitter will be the instrument of choice. Resolution to 0.2 µs is feasible. |
Instrumenting a Pulsed Laser System |
|
|
![]()
Pinout
Laureate 4-20 mA Transmitter
Stopwatch for Single Events or Accumulated Events
(shown with optional dual relay
output)
|
|
|
|
Transmitter
Powering a Single Sensor |
|
|
|
![]() |
| Transmitter Powering Two Sensors | Transmitter with Active or Passive Sensors |
![]()
Ordering
Guide
Laureate 4-20 mA Transmitter
Stopwatch for Single Events or Accumulated Events
|
Create a model
number in this format: TA202FR. This is for a 4-20 mA transmitter,
Standard main board, 95-240 Vac power, isolated dual
solid state relays, and dual channel pulse input
signal conditioner. Includes detachable screw clamp
connectors. |
|
Transmitter Type |
TA Laureate 4-20 mA Transmitter. | $235 |
| Main Board | 6 Standard Main Board. | NC |
| Power |
0 Isolated 95-240 Vac & 90-300 Vdc 1 Isolated 12-30 Vac & 10-48 Vdc. |
NC $30 |
|
Setpoint Output |
0 None. 2 Isolated Dual Solid State Relays. |
NC $30 |
| Input Type | FR Dual Channel Pulse Input Signal Conditioner. | NC |
| Accessories |
CBL03 RS-232 cable, TA to computer. CBL02 USB to RS-232 cable adapter. |
$19 $39 |
|