4-20 mA Current Output Transmitter
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
![]() |
|
|
![]()
Standard Features
|
![]()
Description The Laureate 4-20 mA output strain gauge transmitter is ideal for use with strain gauges, load cells, bridge networks and potentiometer follower circuits whose output requires zero and span adjustment. An isolated 120 mA, 10V transducer excitation supply is built in and can power up to four 350 ohm load cells in parallel. The two most sensitive voltage ranges, 200 mV and 2V, provide a high input impedance of 1 Gohm to minimize the load on the voltage signal. Strain gauges with a 20 mV output can be internally scaled to display up to 10,000 internal counts, while outputs of 200 mV can be scaled to 99,999 internal counts. For ten times higher sensitivity, use Laureate 4-20 mA load cell transmitters, which allow a 20 mV output to be scaled to the full 99,999 counts. Fast read rate at up to 50 or 60 conversions per second while integrating the signal over a full power line cycle is provided by Concurrent Slope (Pat 5,262,780) analog-to-digital conversion. High read rate is ideal for peak or valley capture and for real-time computer interface and control. Digital signal filtering modes are selectable for stable readings in electrically noisy environments. The internal digital readings and analog output can be separately selected to be either unfiltered or filtered.
Three analog transmitter settings are jumper selectable: 4-20 mA, 0-20 mA or 0-10V. All selections provide 16-bit (0.0015%) resolution of output span and 0.02% output accuracy. The output tracks the reading from -99,999 to +99,999 counts that would be transmitted digitally. For DC signals, this reading has a rated accuracy of ±0.01% of full scale input and can be scaled in software. Output isolation from signal and power grounds eliminates potential ground loop problems. The supply can drive 20 mA into a 500 ohm (or lower) load for 10V compliance, or 10V into a 5K ohm (or higher) load for 2 mA compliance. Standard features of Laureate transmitters include:
Easy Transmitter programming is via Laurel's Instrument Setup Software, which runs on a PC under MS Windows. This software can be downloaded from this website at no charge. The required transmitter-to-PC interface cable is available from Laurel (P/N CBL04). |
![]()
Specifications
Laureate 4-20 mA Transmitter
for Strain Gauge & Potentiometer Input
|
Analog Input |
Range | Input Ohms |
|
Voltage |
200.00 mV 2.0000 V 20.000 V 200.00 V 600.0 V |
1 Gohm 1 Gohm 10 Mohm 10 Mohm 10 Mohm |
|
Current |
2.0000 mA 20.000 mA 200.00 mA 5.000 A |
100 ohms 10 ohms 1 ohm 0.01 ohm |
|
Input Resolution |
16 bits (65,536 steps) |
|
|
Analog Output (standard) |
||
|
Output Levels |
4-20 mA, 0-20 mA, 0-10 Vdc (jumper selectable) |
|
|
Transducer Excitation Output (standard) |
||
|
Output Levels |
5V@100 mA, 10 @120 mA, 24V@50 mA (jumper
selectable) |
|
|
Dual Relay Output (standard) |
||
|
Relay Type |
Two solid state relays, SPST, normally open,
Form A |
|
|
Serial Communications (standard) |
||
|
Signal Types |
RS232 (default) or RS485 (half or full duplex) |
|
|
Power Input |
||
|
Standard Power |
85-264 Vac or 90-300 Vdc (DC operation not UL approved) |
|
|
Mechanical |
||
|
Dimensions |
120 x 101 x 22.5 mm |
|
|
Environmental |
||
|
Operating
Temperature |
0°C
to 55°C |
|
![]()
Pinouts
Laureate 4-20 mA
Transmitter
for Strain Gauge & Potentiometer Input

![]()
Potentiometer Follower Application

|
In potentiometric (or potentiometer follower) applications, the signal from a sliding contact voltage divider can be converted to engineering units such as position, level or percentage. By operating in a ratiometric mode, the transmitter will remove any effects caused by variations in the excitation supply. For use with a 1 kohm potentiometer, the recommended applied excitation voltage is 10V. A 2 kohm resistor should be placed in series with the excitation output and excitation return leads. This will allow the transmitter's 2V scale with a high input impedance of 1 Gohm to be used. |
![]()
Ordering
Guide
Laureate 4-20 mA Transmitter
for Strain Gauge & Potentiometer Input
Click on the radio buttons to build a model number with pricing (shown below the Ordering Guide).
|