Dual Pulse Input Channels for
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Features Standard Main Board
Extended Main Board
|
![]()
|
![]()
Description Frequency, Rate or Period from Pulse or AC Signals
Exceptional Accuracy and Stability at High Read Rates
Serial Data I/O & Programming
Transmitter Options
DIN Rail Mounting
|
![]()
Specifications
Laureate Serial Output Transmitters
Pulse Input for Frequency, Rate or Period
| Pulse Input | |
|
Types Ch A Frequency, Max Ch B Frequency, Max Signal Ground Minimum Signal Maximum Signal Maximum Frequency Contact Debounce Time Base Accuracy Span Tempco Long-term Drift |
AC,
pulses from NPN, PNP transistors, contact closures, magnetic pickups. 1 MHz. 250 kHz. Common ground for channels A & B. Nine ranges from (-12 to +12 mV) to (+1.25 to +2.1V). 250 Vac 1 MHz, 30 kHz, 250 Hz (selectable). 0, 3, 50 ms (selectable). Quartz crystal calibrated to ±2 ppm. ±1 ppm/°C (typ) ±5 ppm/year |
| Serial I/O (standard) | |
|
Signal levels Data Rates Output Isolation Serial Protocols Devices on RS-485 Line Modbus Addresses Modbus Modes Modbus Compliance |
RS485 (default) or RS232 (jumper selectable) 300, 600, 1200, 2400, 4800, 9600, 19200 baud 250V rms working, 2.3 kV rms per 1 min test. Modbus RTU, Modbus ASCII, Laurel ASCII (selectable) 32 max without a repeater. 247 max RTU or ASCII, 2-wire. Modbus over Serial Line Specification V1.0 (2002). |
| Transducer Excitation Output (standard) | |
|
Jumper Selection 1 Jumper Selection 2 Jumper Selection 3 |
10V @ 60 mA, isolated to 50V from signal ground 5V @ 50 mA, isolated to 50V from signal ground 15V @ 60 mA, non-isolated |
| Dual Relay Output (optional) | |
|
Relay Type Load rating |
Two solid state relays, SPST, normally open,
Form A 120 mA at 130 Vac or 170 Vdc, 28 ohms series resistance. |
| Analog Output (optional) | |
|
Output Levels Compliance, 4-20 mA Compliance, 0-10V Output Resolution Output Accuracy Output Isolation |
0-20 mA, 4-20 mA or 0-10 Vdc (selectable) 10V ( 0-500 ohm load ) 2 mA ( 5 kOhm load ) 12 bits (4,096 steps) ±0.05% of output span 250V rms working, 2.3 kV rms per 1 minute test |
| Power Input | |
|
Standard power Low power option Frequency Power Isolation |
95-240V AC ±10% or 90-300V DC 12-30V AC or 10-48V DC DC or 47-63 Hz 250V rms working, 2.3 kV rms per 1 min test. |
| Mechanical | |
|
Case Dimensions Case Mounting Electrical Connections |
120 x 101 x 22.5 mm 35 mm rail per DIN EN 50022 Detachable screw clamp plug connectors |
| Environmental | |
|
Operating Temperature Storage Temperature Relative Humidity |
0°C to
70°C -40°C to 85°C 95% at 40°C, non-condensing |
![]()
| Typical Applications | |
AC Line Frequency |
|
|
|
The Laureate will accept line voltages up to 250 Vac and display line frequency to 6-digit accuracy (50.0000 or 60.0000) in a few line cycles. Fast low frequency response is achieved by timing the period and taking its inverse. |
RPM and Speed |
|
|
|
The Laureate can sense the low-level signals from magnetic pickups or the NPN or PNP transistor output of active sensors. These can be powered directly by the meter. Display in RPM or units of speed is achieved by mathematically scaling the meter. |
Flow Rate and Simultaneous Total |
|
|
|
The Laureate is compatible with all flow meters which generate pulses at a frequency proportional to flow rate. The Extended version can display scaled rate or total for the same input at the push of a button, and alarm from both the rate and total. The Extended version can also linearize flow transducers so as to extend their dynamic range. |
Combining Two Rates |
|
![]() |
The Extended Laureate offers A+B, A-B and A/B arithmetic functions. A+B allows two input flows to be summed for total flow, while A-B allows outflow to be subtracted from inflow for net flow. Flow ratios aid in the proper mixing of ingredients |
Custom Curve Linearization |
|
![]() |
The Extended Laureate can linearize the output turbine flow meters, which tend to be nonlinear on the low end. Linearizing improves the dynamic range and accuracy of turbine flow meters. |
System-level Capabilities |
|
The Laureate dual channel rate meter can independently scale, display and alarm two pulse input channels. All signal or alarm data can further be transmitted via RS-232 or RS-485, including peak readings and arithmetic combinations of the two rates. The displayed rates can also be transmitted as isolated isolated 4-20 mA or 0-10V analog output. |
|
![]()
Pinout
Laureate Serial Output Transmitters
Pulse Input for Frequency, Rate or Period
(shown with optional analog output
and dual relay
output)
|
|
|
|
Transmitter
Powering a Single Sensor |
|
|
|
![]() |
| Transmitter Powering Two Sensors | Transmitter with Active or Passive Sensors |
![]()
Ordering
Guide
Modbus
or Laurel ASCII Protocol Serial I/O Transmitters,
Pulse Input for Frequency, Rate or Period
|
Create a
model number in this format: TA6020FR. This example calls out a
Modbus output transmitter, standard main board, 95-240
Vac power, isolated dual solid state relays, no analog output, and a dual signal
pulse input signal conditioner. Includes plug-in screw
clamp
connectors. |
|
Transmitter Type |
TM Laureate Transmitter, Modbus or Laurel ASCII Protocol. | $210 |
| Main Board |
6 Standard Main Board. 8 Extended Main Board Note: Extended allows custom curve linearization and rate from successive readings. |
NC $40 |
| Power |
0 Isolated 95-240 Vac & 90-300 Vdc 1 Isolated 12-30 Vac & 10-48 Vdc. |
NC $30 |
|
Setpoint Output |
0 None. 2 Isolated Dual Solid State Relays. |
NC $30 |
| Analog Output |
0 None. 1 4-20 mA or 0-10V analog output. |
NC $25 |
| Input Type | FR Dual-Channel Frequency. | NC |
| Accessories |
CBL03 RS-232 cable, TM to computer. CBL02 USB to RS-232 cable adapter. |
$19 $39 |
|
Resource Pages |
|
3183-G Airway Avenue Costa Mesa, CA 92626, USA |
||
|---|---|---|---|
|
|
|