Modbus & Serial Output
Thermcouple Transmitter
Exceptional linearity & accuracy at high update rates.
DIN Rail mounted, digitally
programmable.

Standard Features
- Factory calibrated for thermocouple types J, K, T, E, N, R, S
- RS232 or RS485 serial communications,
half or full duplex, isolated
- Modbus RTU, Modbus ASCII
or Laurel ASCII protocol
- Highly accurate and repeatable
- Upscale or downscale open sensor
indication
- Output update rate to 60/sec
- Universal AC switching power supply for 85-264 Vac
- DIN rail mount housing only 22.5 mm wide
- Detachable screw-clamp connectors
- User selectable
4-20 mA, 0-20 mA or 0-10 Vdc linearized analog
output
- Analog output resolution: 0.0015% of span (16 bits)
- Dual solid state relays for alarm or control, isolated
- RS232 or RS485 serial communications, isolated
- Universal AC power, 85-264 Vac
- Easy setup with PC-based
Instrument Setup Software
- Priced at only $235
(basic temperature transmitter)
Options:
- Low voltage power,
10-48 Vdc or 12-32 Vac
|

Description
The Laureate Modbus & serial
output thermocouple transmitter provides
a linearized, highly accurate, stable
and repeatable transmitter output for thermocouple types J, K, T, E, N, R
or S. The
thermocouple or RTD type and temperature range, specified in °C or °F, are
user-selectable.

Digital
calibration of all
thermocouple ranges is performed the factory, with calibration data stored
in EEPROM on the signal conditioner board. This allows signal
conditioner boards and ranges to be changed in the field with no need for
recalibration. Cold junction compensation automatically
corrects for temperature variations at the thermocouple reference junction at the
transmitter.
Open sensor indication is standard and may be set up to indicate either upscale or
downscale.
Fast update rates at up to 50
or 60 conversions per second while integrating the signal over a
full power line cycle are provided by Concurrent Slope (Pat 5,262,780)
analog-to-digital conversion. High read
rate is ideal for peak or valley capture and for real-time computer interface and control.
LTM Series serial
output transmitters send data via an isolated serial port, which is user
configurable for RS232 or RS485 and full or half duplex operation. Three
protocols are user selectable: Modbus RTU, Modbus ASCII, or Laurel ASCII. Modbus operation
is fully compliant with Modbus Over Serial Line Specification V1.0 (2002).
The Laurel ASCII
protocol allows up to 31 Laureate devices to be addressed on the
same RS485 data line. It is simpler than the Modbus protocol and is
recommended when all devices are Laureates. It also allows use of
Laurel Datalogging Software.
Standard features of Laureate
temperature transmitters include:
- Serial data output, isolated. User selectable RS232 or RS485, half or full duplex, Modbus or
Laurel ASCII protocol.
- Dual solid state relays for control or alarm, isolated.
Rated 120 mA at 130 Vac or 170 Vdc.
-
Analog transmitter output, 16-bit, user scalable and isolated. User selectable 4-20 mA,
0-20 mA or 0-10V levels.
- Universal AC power supply for 85-264 Vac.
Low voltage power of
10-48 Vdc or 12-32 Vac is optional.
Easy Transmitter programming is via
Laurel's Instrument Setup Software,
which runs on a PC under MS Windows. This software can be downloaded from this website at no charge. The required transmitter-to-PC interface cable is available from
Laurel (P/N CBL04).
|

Specifications
Laureate Modbus & Serial Output
Thermocouple Temperature Transmitter
|
TC Types |
Range |
Conformity Error |
| J |
-210°C to
+760°C (-347°F to +1400°F) |
±0.09°C
(±0.16°F) |
| K |
-244°C to
+1372°C (-408°F to +2501°F) |
±0.1°C
(±0.17°F) |
| T |
0°C to
+400°C (32°F to 752°F)
-257°C to 0°C (-430°F to +32°F) |
±0.03°C
(±0.05°F)
±0.2°C (±0.36°F) |
| E |
-240°C to
+1000°C (-400°F to +1830°F) |
±0.18°C
(±0.32°F) |
| N |
-245°C to
+1300°C (-410°F to +2370°F) |
±0.10°C
(±0.17°F) |
| R |
-45°C to
+1768°C (-49°F to +3214°F) |
±0.17°C
(±0.31°F) |
| S |
-46°C to
+1768°C (-51°F to +3213°F) |
±0.12°C
(±0.22°F) |
|
Thermocouple
Input |
|
Calibration
Input resistance
Input current
Max lead resistance
Overall accuracy
Span tempco
Reference junction tempco
Span tempco
Over-voltage protection
NMR at 50/60 Hz
CMR, DC-60 Hz
CMV, DC-60 Hz
Open sensor indication |
NIST
Monograph 125 (IPTS-68)
1 Gohm
100 pA
1 kohm max for rated accuracy
±0.01 of full scale ±2 counts
±0.003% of reading/ºC
±0.02 deg/deg
±0.003% of reading/ºC
125 Vac
80 dB plus selectable filter from 80 ms
to 9.6 s time constant
120 dB with 500 W imbalance
250 Vac from power and earth grounds
0 mA or > 20mA output, selectable |
|
Serial Data Output
(standard) |
|
Signal Types
Data Rates
Output Isolation
Serial Protocols
Modbus Modes
Modbus Compliance
Digital Addressing |
RS232 or RS485 (half or full duplex)
300, 600, 1200, 2400, 4800, 9600, 19200 baud
250V rms working, 2.3 kV rms per 1 min test
Modbus RTU, Modbus ASCII, Laurel ASCII
RTU or ASCII
Modbus over Serial Line Specification V1.0 (2002)
247 Modbus addresses.
Up to 32 devices on an RS485 line w/o a repeater. |
|
Analog Output (standard) |
|
Output Levels
Compliance, 4-20 mA
Compliance, 0-10V
Output Resolution
Output Accuracy
Output Isolation |
4-20 mA, 0-20 mA, 0-10 Vdc (jumper selectable)
10V ( 0-500 ohm load )
2 mA ( 5 kOhm load or higher)
16 bits (65,536 steps)
0.02% of output span plus conversion accuracy
250V rms working, 2.3 kV rms per 1 minute test |
|
Dual Relay Output (standard) |
|
Relay Type
Load Rating |
Two solid state relays, SPST, normally open,
Form A
130 mA at 140 Vac or 180 Vdc |
|
Power Input |
|
Standard Power
Low Power Option
Power Frequency
Power Isolation
Power Consumption |
85-264 Vac or 90-300 Vdc (DC operation not UL
approved)
10-48 Vdc or 12-32 Vac
DC or 47-63 Hz
250V rms working, 2.3 kV rms per 1 min test
2W typical |
|
Mechanical |
|
Dimensions
Mounting
Electrical Connections |
120 x 101 x 22.5 mm
35 mm rail per DIN EN 50022
Plug-in screw-clamp connectors |
|
Environmental |
|
Operating
Temperature
Storage Temperature
Relative Humidity
Cooling Required |
0°C
to 55°C
-40°C to 85°C
95% at 40°C, non-condensing
Mount transmitters with ventilation holes at top and bottom.
Leave 6 mm (1/4") between transmitters, or force air with a fan. |

Specifications
Laureate Modbus & Serial Output
Thermocouple Temperature Transmitter


Operation as a
Fast ON/OFF Controller
or Supervisory Monitor
With the optional dual solid state relay output
option, which has a typical response
time of only 17 ms, Laureate temperature meters
and transmitters can
serve as extremely fast and accurate ON/OFF controllers
for closed-loop temperature control.
They can also serve as
supervisory process monitors and provide alarms or shutoffs when processes exceed normal
limits.
Multiple setpoint operating modes are
individually selectable for each relay, as explained in the
dual-setpoint controller page. Relay duty cycles and chatter can be minimized with programmable hysteresis and
time delays. A band deviation operating mode can be
selected for each relay, where an alarm is generated whenever the reading is a selected
number of counts above or below the setpoint. With Modbus, relay operation
can be non-latching or latching, with reset provided by digital commands.
|

Ordering
Guide
Laureate Modbus & Serial Output
Thermocouple Temperature Transmitter
Click on the radio buttons to build a model number with pricing (shown below the Ordering Guide).
|