Load Cell Strain Gauge and Microvolt
Accuracy of 0.01% of reading ± 2 counts. High read rates at up to 60 or 50 conversions per second.
Load Cell Strain Gauge and Microvolt
Accuracy of 0.01% of reading ± 2 counts. High read rates at up to 60 or 50 conversions per second.
Scale Meter for Weighing
Accuracy of 0.01% of reading ± 2 counts. High read rates at up to 60 or 50 conversions per second.
Process and Ratiometric Meter
Accuracy of 0.01% of reading ± 2 counts. High read rates at up to 60 or 50 conversions per second.
6-Digit Digital Stopwatch and Timer
Time Base Crystal calibrated to ±2 ppm Span tempco ±1 ppm/°C (typ)
Long-term Drift ±5 ppm/year (typ)
Time Interval of Periodic Events
Time Base Crystal calibrated to ±2 ppmSpan tempco ±1 ppm/°C (typ)
Long-term Drift ±5 ppm/year (typ)
True RMS AC Voltage & Current meter
Accuracy of 0.01% of reading ± 2 counts. High read rates at up to 60 or 50 conversions per second.
Duty Cycle and (PWM) Meter
Time Base Crystal calibrated to ±2 ppmSpan tempco ±1 ppm/°C (typ)
Long-term Drift ±5 ppm/year (typ)
Frequency, Rate & Period
Time Base Crystal calibrated to ±2 ppm
Span tempco ±1 ppm/°C (typ)
Long-term Drift ±5 ppm/year (typ)
Thermocouple Temperature Meter
Accuracy of 0.01% of reading ± 2 counts. High read rates at up to 60 or 50 conversions per second.
Rate, Totalizer with Functions
Time Base Crystal calibrated to ±2 ppm
Span tempco ±1 ppm/°C (typ)
Long-term Drift ±5 ppm/year (typ)
RTD Temperature Meter
Accuracy of 0.01% of reading ± 2 counts. High read rates at up to 60 or 50 conversions per second.
Serial Input 6-Digit Remote Display
Display from -999,999 to +999,999
High read rates at up to 60 or 50 conversions per second.
Pulse Input Totalizer
Time Base Crystal calibrated to ±2 ppm
Span tempco ±1 ppm/°C (typ)
Long-term Drift ±5 ppm/year (typ)
Ohmmeter for Resistance in Ohms
Accuracy of 0.01% of reading ± 2 counts. High read rates at up to 60 or 50 conversions per second.
Analog Input Totalizer
Time Base Crystal calibrated to ±2 ppm
Span tempco ±1 ppm/°C (typ)
Long-term Drift ±5 ppm/year (typ)
Batch Controller Pulse Input
Time Base Crystal calibrated to ±2 ppm
Span tempco ±1 ppm/°C (typ)
Long-term Drift ±5 ppm/year (typ)
Batch Controller Analog Input
Time Base Crystal calibrated to ±2 ppm
Span tempco ±1 ppm/°C (typ)
Long-term Drift ±5 ppm/year (typ)
AC Phase, Angle, and Power Factor
Time Base Crystal calibrated to ±2 ppm
Span tempco ±1 ppm/°C (typ)
Long-term Drift ±5 ppm/year (typ)
Quadrature Encoder Input
Time Base Crystal calibrated to ±2 ppm
Span tempco ±1 ppm/°C (typ)
Long-term Drift ±5 ppm/year (typ)
DC Voltage & Current Input Signal
Accuracy of 0.01% of reading ± 2 counts. High read rates at up to 60 or 50 conversions per second.
Vac & Vdc Power Boards
85-264 Vac or 90-300 Vdc power supply 12-32 Vac or 10-48 Vdc
power supply
Dual or Quad Relay Boards
Dual or Quad From C contact relays
Dual or Quad 120 mA solid state relays
Analog output Boards
4-20 mA, 0-20 mA, 0-10V, -10 to +10V
4-20 mA, 0-20 mA, 0-10V