Features
- Five jumper-selectable resistance ranges of 20.000 ohm to 200.00 kohm
- Three fixed factory-special ranges of 2.0000 ohm, 2.0000 Mohm, 20.000 Mohm
- Accuracy at 25°C ±0.01% of reading ± 2 counts
- 0.1 milliohm resolution on 2 ohm scale for contact resistance measurements
- 2, 3 or 4-wire connection with lead resistance compensation
- All input ranges are user selectable and factory calibrated
- Up to 60 conversions per second, Ideal for peak or valley capture
- Digital span adjust from 0 to ±99,999, zero adjust from -99,999 to +99,999
- Front panel scalable to ±99,999 for use with current shunts
- 1/8 DIN size with bright red or green 0.56" (14.2mm), high LED digits
- Power 85-264 Vac / 90-300 Vdc or 10-48 Vdc / 12-32 Vac (isolated)
- Operating temperature from -40°C to 70°C (-40°F to 158°F)
- Wide choice of Plug-in-Play options:
- 2 or 4 relays, mechanical or solid state, for alarm or control (isolated)
- 1 or 2 Analog output, 4-20 mA, 0-20 mA, 0-10V, or -10V to +10V (isolated)
- Communications: Ethernet, WiFi, USB, RS232, RS485 (isolated)
- Extended DPM allows up to 180 data points to linearize and scale
nonlinear resistance sources
The Laureate™ 1/8 DIN Digital Panel Meter, Ohmmeter for resistance in Ohms
is ideal for high-speed, high-accuracy resistance measurements in a production environment, such as contact resistance measurements. It is factory calibrated for five jumper selectable resistance ranges from 20.000 ohm to 200.00 kohm. Fixed, factory-special ranges of 2.0000 ohm, 2.0000 Mohm and 20.000 Mohm are also available. Accuracy is an exceptional ±0.01% of reading ± 2 counts. Resolution is one part in 20,000. In the 2 ohm range, resolution is 0.1 milliohm, making the meter suitable for contact resistance measurements.The optional extended Laureate computer board enhances Laureate Digital Panel Meters by displaying rates derived from successive readings and enabling highly accurate custom curve linearization. For example, it can calculate liquid volume or flow rate in a horizontal cylindrical tank using levels from a 4-20 mA transmitter. Setup is straightforward: users input up to 180 data points into a spreadsheet or text file, and the computer calculates spline-fit segments, which are then downloaded to the meter for precise operation.
Meter connections can be via 2, 3 or 4 wires. With 4-wire hookup, 2 wires are used for excitation and two separate wires are used to sense the voltage across the resistance to be measured, thereby eliminating any lead resistance effects. With 3-wire hookup, the meter senses the combined voltage drop across the resistance to be measured plus two excitation leads. It also senses the voltage drop across one excitation lead, and then subtracts twice this voltage from the combined total. This technique effectively subtracts lead resistance if the excitation leads are the same.
All resistance ranges are factory-calibrated, with calibration factors for each range securely stored in an onboard EEPROM. These factors can be scaled via software to accommodate external shunts, enabling field replacement of signal conditioner boards without necessitating recalibration of the associated digital panel meter. For optimal accuracy, factory recalibration is recommended annually. All Laurel Electronics instruments undergo factory calibration using the industry-leading Fluke calibrators, which are recalibrated yearly and certified traceable to national standards, ensuring the highest level of precision and reliability.
Laureate Digital Panel Meters are easily programmed with Laurel’s free Instrument Setup Software, downloadable from our website and compatible with Windows PCs, requiring a data interface board for setup.
High read rate of up to 50 or 60 conversions per second, the Laureate™ Digital Panel Meter uses Concurrent Slope (US Pat. 5,262,780) analog-to-digital conversion to integrate signals over a full power line cycle (50 Hz or 60 Hz). This read rate enables peak and valley capture, real-time computer interfacing, and control applications. Peak and valley values are automatically captured and can be viewed using Laurel’s free Instrument Setup Software (compatible with Windows PCs) or transmitted as serial data.
- An unfiltered selection provides true peak and valley readings and aids in control applications.
- A batch average filter selection averages each 16 conversions.
- An adaptive moving average filter selection provides a choice of 8 time constants from 80 ms to 9.6 seconds. When a significant change in signal level occurs, the filter adapts by briefly switching to the shortest time to follow the change, then reverts back to its selected time constant. An Auto setting selects the time constant selection based on signal noise.
Two tare functions: auto-tare and manual tare. In auto-tare, an input line is grounded by an external pushbutton. This causes the current weight, which is normally the empty weight of the container to be stored in memory as an offset. In manual tare, the tare value can be entered manually via the front panel or a computer using Laurel's free Instrument Setup Software. For instance, the tare value may be the stated empty weight of a truck or rail car. Pressing the Reset button on the front panel toggles the display between gross weight (total weight on the scale) and net weight (gross weight with tare subtracted).
Peak and valley values are automatically captured. These may be displayed via a front panel pushbutton command or control signal at the rear connector, or be transmitted as serial data.
Two rear panel control Inputs (CMOS/TTL levels, logic 0 = tied to digital ground, logic 1 = open) or dry contacts that can be set to control / activate 14 meter commands.
Resistance Measurement with Excitation & Lead Compensation
Ohmmeter hookup can be via 2, 3 or 4 wires to the J5 connector. The meter applies a fixed excitation current for each resistance range. | |
![]() |
In 4-wire hookup, different pairs of leads are used to apply the excitation current and sense the voltage drop across the unknown resistance, so that the IR drop across the excitation leads is not a factor. |
![]() |
In 3-wire hookup, the meter senses the combined voltage drop across the unknown resistance plus two excitation leads. It also senses the voltage drop across one excitation lead, and then subtracts twice this voltage from the combined total. This technique effectively subtracts all lead resistance and compensates for ambient temperature changes if the two excitation leads are identical. |
![]() |
In 2-wire hookup, the meter senses the combined voltage drop across the unknown resistance and both lead wires. The voltage drop across the lead wires can be measured by shorting out the resistance during meter setup, and this voltage is then automatically subtracted from the combined total. However, changing resistance of the lead wires due to ambient temperature changes will not be compensated. |
QA Application with Relay Option in Passband Mode
![]() |
A deviation limit (50 mohm in this example) is set up around both sides of a setpoint. The relay closes (or opens) when the reading falls within the deviation band, and opens (or closes) when the reading falls outside of this band. This mode sets up a passband around the setpoint and can be used for contact resistance testing.
|
Modular Design for Maximum Flexibility at Minimum Cost
All boards are isolated from meter and power grounds. Optional Plug-in-Play boards for communications and control include Ethernet, WiFi, serial communication boards, dual or quad relay boards, and an analog output board. Laureates may be powered from 85-264 Vac or optionally from 12-32 Vac or 10-48 Vdc. The display is available with bright red or green 0.56" (14.2mm) high LED digits. The 1/8 DIN case meets NEMA 4X (IP65) specifications from the front when panel mounted. Any setup functions and front panel keys can be locked out for simplified usage and security. A built-in 5, 10, 12, or 24 Vdc excitation supply can power transducers, eliminating the need for an external power supply. All power and signal connections are via UL / VDE / CSA rated screw clamp plugs.
The Laureate™ Series features modular design with up to 7 isolated plug-in boards, applicable to all Laureate 1/8 DIN Digital Panel Meters.
Modular Hardware
The design of the Laureate™ Series is modular for maximum flexibility at minimum cost. All boards are isolated from meter and power grounds. The base configuration for a panel meter or counter consists of a main module (with computer and plug-in display boards), a power supply board, and a signal conditioner board. Optional plug-in-play boards include an isolated setpoint controller board, an isolated analog output board, and an isolated digital interface board. Modular design and a choice of plug-in options allow the Laureate to be customized for a broad range of applications from simple monitoring to control and computer interface. There can be up to five plug-in boards in a 1/8 DIN Laureate.

Connecting Laureate Digital Panel Meters to a Local Area Network (LAN)
Up to 30 Laureate Digital Panel Meters and/or LT Transmitters can be configured for RS485 and daisy-chained to an LT Transmitter using Laurel’s High Speed Ethernet-to-RS485 converter board for seamless LAN integration. Alternatively, Laurel LTE series Ethernet transmitters can connect directly to a LAN via an Ethernet cable. Setup for both configurations is streamlined using Laurel’s free Instrument Setup Software, which simplifies node discovery and transmitter configuration.
Flexible Communication Options for Digital Panel Meters
Laureate Digital Panel Meters can be equipped with Laurel communication boards to support various interfaces and protocols. These include serial interfaces with ASCII or Modbus RTU protocols, and Ethernet interfaces with web access, ASCII, or Modbus TCP/IP protocols, ensuring versatile connectivity for your commercial applications.
Range | Ohms | Resolution | Accuracy | Excitation Current *** |
---|---|---|---|---|
R0** | 0-2.0000 Ω | 0.1 mΩ | ±0.01% of reading ± 2 counts |
5 mA |
R1* | 0-20.000 Ω | 1 mΩ | 5 mA | |
R2* | 0-200.00 Ω | 10 mΩ | 500 µA | |
R3* | 0-2000.0 Ω | 100 mΩ | 50 µA | |
R4* | 0-20000 Ω | 1 Ω | 5 µA | |
R5* | 0-200.00 kΩ | 10 Ω | 500 nA | |
R6** | 0-2.0000 MΩ | 100 Ω | 500 nA | |
R7** | 0-20.0000 MΩ | 1000 Ω | 80 nA | |
* Jumper-selectable, precalibrated range. | ||||
** Factory-set fixed range. | ||||
*** The applied excitation current is sensed by the meter, which operates in a ratiometric mode and automatically compensates for any changes in excitation. | ||||
Recalibration: All ranges are calibrated at the factory. Recalibration is recommended every 12 months. |
Display | |
---|---|
Readout | 5 LED digits, 7-segment, 14.2 mm (.56") |
Color | Red or green LED |
Indicators | 2 red LED lamps |
Accuracy | |
Accuracy at 25°C | ±0.01% of reading ± 2 counts |
Span tempco | ±0.003% of reading/°C |
Electrical | |
Connection | 2, 3 or 4-wire |
Max applied voltage | 100 mV |
Overvoltage protection | 125 Vac |
Open sensor indication | Flashes full-scale |
A-to-D Conversion | |
Technique | Concurrent Slope (Pat 5,262,780) |
A-to-D rate | 60/s at 60 Hz, 50/s at 50 Hz |
Output update rate | 56/s at 60 Hz, 47/s at 50 Hz |
Display update rate | 3.5/s at 60 Hz, 3/s at 50 Hz |
Power Supply Boards (one required) | |
Voltage, standard | 85-264 Vac or 90-300 Vdc |
Voltage, optional | 12-32 Vac or 10-48 Vdc |
Frequency | DC or 47-63 Hz |
Power consumption (typical, base meter) | 1.2W @ 120 Vac, 1.5W @ 240 Vac, 1.3W @ 10 Vdc, 1.4W @ 20 Vdc, 1.55W @ 30 Vdc, 1.8W @ 40 Vdc, 2.15W @ 48 Vdc |
Power Isolation | 250V rms working, 2.3 kV rms per 1 min test |
Analog Output Board (one optional) | |
Output levels | 4-20 mA, 0-20 mA, 0-10V, -10 to +10V (jumper selectable) |
Current compliance | 2 mA at 10V ( > 5 kΩ load) |
Voltage compliance | 12V at 20 mA (< 600 Ω load) |
Scaling | Zero and full scale adjustable from -99999 to +99999 |
Resolution | 16 bits (0.0015% of full scale) |
Step function response | 80 ms to 99% of final value (typ) |
Isolation | 250V rms working, 2.3 kV rms per 1 min test |
Relay Output Boards (one optional) | |
Dual magnetic relays | 2 Form C, 8A max, 440Vac or 125Vdc max, 2500VA or 300W |
Quad magnetic relays | 4 Form A (NO), 8A max, 440Vac or 125Vdc max, 2500VA or 300W |
Dual solid state relays | 2 Form A (NO), AC or DC, 0V - 400V, 120Ma, 35Ohms (max at On-State) |
Quad solid state relays | 4 Form A (NO), AC or DC, 0V - 400V, 120Ma, 35Ohms (max at On-State) |
Relay commons | Isolated commons for dual relays or each pair of quad relays |
Relay isolation | 250V rms working, 2.3 kV rms per 1 minute test |
Step function response | 30 ms (typ) for contact relays, 25 ms (typ) for solid state relays |
Relay latching modes | Latching or non-latching |
Relay active modes | Active on or off, active high or low |
Hysteresis modes | QA passband mode, split hysteresis, span hysteresis |
Communication Boards (one optional) | |
Board selections | RS232, RS485 with dual RJ11 connectors, RS485 with dual RJ45 connectors, USB, Ethernet, USB-to-RS485 gateway, Ethernet-to-RS485 gateway, WiFi with built-in antenna plus USB & RS485, WiFi with external antenna plus USB & RS485 |
Protocols | Laurel Custom ASCII (serial), Modbus RTU (serial), Modbus TCP (Ethernet or WiFi) |
Digital addresses | 247 (Modbus), 31 (Laurel ASCII), |
Isolation | 250V rms working, 2.3 kV rms per 1 min test |
Environmental | |
Operating temperature | -40°C to 70°C (-40°F to 158°F) |
Storage temperature. | -40°C to 85°C (-40°F to 185°F) |
Relative humidity | 95% at 40°C, non-condensing |
Protection | NEMA-4X (IP-65) when panel mounted |
Mechanical | |
Enclosure | 1/8 DIN, high impact plastic, UL 94V-0, color: black |
Mounting | 1/8 DIN panel cutout required: 3.622" x 1.772" (92 mm x 45 mm). |
Dimensions | 4.68" x 2.45" x 5.64" (119 mm x 62 mm x 143 mm) (W x H x D) |
Maximum panel thickness | 4.5 mm (0.18") |
Tightening Torque - Connectors | Screw terminal connectors: 5 lb-in (0.56 Nm) |
Tightening Torque - Pawls | Digital Panel Meter Case Pawls: 5 lb-in (0.56 Nm) |
Weight of base meter | 210 g (7.4 oz) typical (DPM, counter, timer, 6-digit remote display) |
Weight of option boards | 30 g (1.0 oz) typical per board (analog output, relay output, communications) |
General | |
Programming Methods | Four front panel buttons or via Laurel's free Instrument Setup Software, which runs on a PC under MS Windows. |
Security | Lockout options include using the front panel buttons, the free Instrument Setup Software, or a hardware jumper. |
Warranty | 3 years parts & labor |
Recalibration: All ranges are calibrated at the factory. Recalibration is recommended every 12 months. |
Free Instrument Setup Software for Series 2 Laureates
Free Downloadable Windows-based Instrument Setup (IS) software (Data Interface Board Required) for use with our programmable Digital Panel Meters, Scale Meters, Counters, Timers, Remote Displays, and Transmitters, are an easy method to set up Laureate 1/8 DIN digital panel meters, counters, timers, remote displays, and DIN-rail transmitters, as explained in the Instrument Setup Software Manual. Laureate 1/8 DIN instruments can also be set up from the front panel, as explained in their respective Owners Manuals. Instrument Setup software is of benefit whether or not the PC is connected to the instrument.
- When the PC is connected to the instrument, Instrument Setup software can retrieve the setup file from the instrument or open a default setup file or previously saved setup file from disk View Setup, then provides graphical user interface (GUI) screens with pull-down menus applicable to input, display, scaling, filtering, alarms, communications, analog output, and front panel lockouts. Fields that are not applicable to the instrument as configured are either left out or grayed out. Clicking on any item will bring up a detailed Help screen for that item. After editing, the setup file can be downloaded, uploaded to the instrument, or saved to a disk. The same setup file can then be downloaded into multiple instruments.
- When the PC is not connected to the instrument, the above GUI screens can be used to set up a virtual instrument. The setup file can then be saved to disk. Switching toView Menu then brings up a screen with the required front panel programming steps. This view can be printed out for use at the instrument site and to serve as a hard copy record.
Download Free Instrument Setup Software
Installation
Set User Account Control (UAC) of MS Windows to "Never notifiy me" so that Instrument Setup Software can create directories. The UAC change screen can be reached as follows:
- Under Windows 7, click on the Windows Start button in the lower left of the desktop and enter "UAC" in the search field.
- Under Windows 8, navigate to Control Panel, then to the "User Accounts and Family Safety" section, and click on "Change User Account Control Settings."
- Under Windows 10, click on the Windows Start button in the lower left of the desktop, then on "Settings", and enter "UAC" in the search field.
- Reboot your computer for the changed UAC setting to take effect.

RJ11-to-DB9 cable with rear view of DB9 connector to PC

RS232 cable, meter to PC, P/N CBL01
Laureate 1/8 DIN Laureate instruments must be equipped with a serial communications board and be connected to the computer via a serial communications cable. The connection can be via RS232, RS485, USB or Ethernet. Following setup, the serial communications board may be removed from the instrument if desired. The wiring of the RS232 cable is illustrated above with end views of the two connectors.
Laureate LT Series transmitters come standard with a 3-wire serial interface, which can be jumpered for RS232 or RS485.
Laureate LTE Series transmitters come standard with an Ethernet interface.
Meter Setup Screens
Click on any of the reduced screens below for a full-size screen view, then click on the Back button of your browser to return to this page. The screens examples below are for a fully-loaded Series 2 Digital Panel Meter (DPM), which is connected to the PC via RS232. If the meter is a Series 1 meter (pre-2007), this is sensed by the software, and somewhat different screens are brought up. Please see Series 1 setup screens.











Meter Setup Utilities




From the Main Menu, click on Readings if your PC is connected to the meter. A pull-down menu then offers three choices: List, Plot and Graph.
- List presents the latest readings in a 20-row by 10-column table. Press Pause at any time to freeze the display. This is one method to capture peak readings.
- Plot generates a plot of readings vs. time in seconds. It effectively turns the DPM-PC combination into a printing digital oscilloscope.
- Graph generates a histogram where the horizontal axis is the reading and the vertical axis is the number of occurrences of readings. The display continually resizes itself as the number of readings increases.


Laureate™ 1/8 DIN Case For Laureate Digital Panel Meters, Counters, Timers & Remote Displays

Key Features
- Meets 1/8 DIN Standard.
- Installs from front of panel.
- Short depth behind the panel: only 4" (102 mm) plus connectors.
- Understated 0.157" (4 mm) thick bezel.
- Meets NEMA 4X (IP-65) for high-pressure wawshdon when panel mounted.
- Screw clamps connectors meet VDE / IEC / UL / CSA safety standards.
- Rugged GE Lexan® housing material.
- Safety certified per EN 61010-1.
Dimensions

Maximum panel thickness: 4.5 mm (0.18")
Weight of base meter: 210 g (7.4 oz) typical (DPM, counter, timer, 6-digit remote display)
Weight of option boards: 30 g (1.0 oz) typical per board (analog output, relay output, communications)
Tightening Torque - Connectors: Screw terminal connectors: 5 lb-in (0.56 Nm)
Tightening Torque - Pawls: Digital Panel Meter Case Pawls: 5 lb-in (0.56 Nm)
Dimensioned CAD assembly drawings in EPRT, STEP, x_t. dwg, pdf file formats: Laureate-meter-case.zip (zipping prevents browser from opening CAD files as text files).
Panel Mounting
Slide the meter into a 45 x 92 mm 1/8 DIN panel cutout. Ensure that the provided gasket is in place between the front of the panel and the back of the meter bezel.
The meter is secured by two pawls, each held by a screw, as illustrated. Turning each screw counterclockwise extends the pawl outward from the case and behind the panel. Turning each screw clockwise further tightens it against the panel to secure the meter.
Turning each screw counterclockwise loosens the pawl and retracts it into its well. This position allows installed meter to be removed from their panel, or new meters to be installed in a panel. Do not remove the screws from their pawls. Doing so would cause the screw and pawl to fall off and likely get lost. Do not overtighten so as not to damage the plastic parts.
IPC
Splashproof Cover
CLB01
RS232 Cable for Meters
CLB02
USB-to-RS232 Adapter Cable
CBL04
RS232 Cable for LT Transmitters
CLB05
USB Data Cable for Meters
CLB06
USB-to-RS485 Adapter Cable
CLB07
USB Programming & Data Cable
CLB08
RS485 Splitter Cable
BKBD
RS485 RJ11 Terminal Block Adapter
What is a Digital Panel Meter Ohmmeter for Resistance in Ohms?
A digital panel meter ohmmeter is a precision instrument designed to measure and display electrical resistance in ohms, typically from resistive sensors, circuits, or components. These meters are vital in industrial, laboratory, and testing applications where accurate resistance measurements are critical, such as in quality control, circuit diagnostics, and sensor calibration. By converting resistance signals into clear digital readouts, digital panel meters ensure reliable data for process monitoring, equipment maintenance, and system optimization.
Unlike traditional analog ohmmeters, digital panel meter ohmmeters offer superior accuracy, programmable features, and integration with modern control systems. Their ability to measure a wide range of resistance values, from micro-ohms to mega-ohms, makes them versatile for diverse applications, including testing electrical components, monitoring sensor performance, and verifying circuit integrity.
Understanding the Digital Panel Meter Ohmmeter
Digital panel meters for ohmmeter applications are typically built to the 1/8 DIN standard, fitting compactly into panel cutouts (approximately 92 mm x 45 mm). This compact size ensures compatibility with control panels while optimizing space, making them ideal for industrial control rooms, test benches, or equipment with limited space.
These meters are designed to measure resistance by applying a known current or voltage to the resistive element and calculating the resulting resistance based on Ohm’s Law (R = V/I). They feature bright LED or LCD displays, user-friendly interfaces, and communication interfaces like RS-485 or Modbus for integration with automation systems. Advanced features, such as 2-, 3-, or 4-wire measurement configurations, ensure high accuracy by compensating for lead resistance, making them suitable for precise resistance measurements in demanding environments.
How Does a Digital Panel Meter Ohmmeter Work?
A digital panel meter ohmmeter measures resistance in ohms and displays the results accurately. Below is a detailed breakdown of its operation:
- Signal Acquisition:
The meter applies a small, controlled current or voltage to the resistive element (e.g., a resistor, sensor, or circuit) and measures the resulting voltage or current to calculate resistance using Ohm’s Law. - Lead Resistance Compensation:
For 3- or 4-wire configurations, the meter compensates for resistance in the connecting wires, ensuring accurate measurements, especially for low-resistance values or long cable runs. - Signal Conditioning:
The resistance signal is conditioned through amplification or filtering to remove noise and ensure it is within the meter’s operational range, minimizing errors from electrical interference. - Analog-to-Digital Conversion:
An Analog-to-Digital Converter (ADC) transforms the conditioned signal into a digital format. High-resolution ADCs are critical for detecting small resistance changes, especially in micro-ohm or high-resistance applications. - Processing and Display:
The digital signal is processed by the meter’s microcontroller, which applies calibration, scaling, and unit conversions (e.g., ohms, kilohms, megaohms). The result is displayed on a clear digital screen, often with customizable units or decimal precision. - Output and Integration:
The meter may provide outputs like 4-20 mA analog signals, relay contacts for alarms, or digital communication (e.g., Ethernet, USB) for integration with PLCs, SCADA systems, or data loggers. - Calibration and Configuration:
Users can calibrate the meter for specific resistance ranges and configure settings like measurement modes, alarm thresholds, or display formats to suit application needs.
Key Features of Digital Panel Meter Ohmmeters
Digital panel meters for ohmmeter applications include features that enhance performance and usability:
- Wide Resistance Range: Measures from micro-ohms to mega-ohms, supporting diverse applications like low-resistance circuit testing or high-resistance insulation checks.
- High Accuracy: Precise ADCs and lead compensation ensure reliable resistance measurements, even for small changes.
- Customizable Displays: Multi-color LEDs, bar graphs, or large-digit displays ensure readability in various lighting conditions.
- Programmable Alarms: Setpoints for high/low resistance conditions trigger alerts or control external devices, such as circuit breakers or test equipment.
- Communication Options: Protocols like Modbus or Profibus enable integration with industrial automation systems.
- Rugged Design: IP65-rated front panels resist dust and moisture, suitable for harsh industrial or laboratory environments.
Applications of Digital Panel Meter Ohmmeters
Digital panel meters for ohmmeter applications are used across various industries for resistance measurements. Key applications include:
- Electrical Component Testing:
In manufacturing, DPMs measure the resistance of resistors, cables, or connectors to ensure they meet specifications and function correctly. - Circuit Diagnostics:
In maintenance, digital panel meters identify faults in electrical circuits by measuring resistance, helping technicians detect open circuits or short circuits. - Sensor Calibration:
In laboratories, DPMs measure resistance from sensors like RTDs or strain gauges during calibration, ensuring accurate performance in temperature or strain applications. - Quality Control:
In production lines, digital panel meters verify the resistance of components like motor windings or transformers, ensuring product reliability and safety. - Insulation Testing:
In electrical systems, DPMs measure high resistance in insulation materials to detect degradation or ensure compliance with safety standards.
Where Are Digital Panel Meter Ohmmeters for Resistance in Ohms Used?
Digital panel meters (DPMs) are essential in industries requiring precise resistance measurements in ohms. With support for a wide range of resistance values and a compact 1/8 DIN design, these meters provide reliable solutions. Below are detailed use cases across key sectors:
- Electronics Manufacturing:
In circuit board production, digital panel meters measure the resistance of components like resistors or traces, ensuring compliance with design specifications and preventing defects. - Automotive Industry:
In automotive testing, DPMs measure the resistance of wiring harnesses or motor windings, verifying electrical integrity and supporting quality control for vehicle systems. - Power Generation and Distribution:
In power plants or substations, digital panel meters monitor the resistance of transformer windings or busbars, detecting degradation to prevent failures and ensure reliable power delivery. - Scientific and Research Laboratories:
In materials science or electronics research, DPMs measure resistance in experimental circuits or sensors, providing accurate data for analysis and development. - Industrial Maintenance and Repair:
In factories, digital panel meters diagnose electrical faults in machinery by measuring resistance, helping maintenance teams identify issues like corroded connections or damaged cables. - Telecommunications:
In telecom systems, DPMs measure the resistance of cables or connectors, ensuring signal integrity and preventing communication disruptions. - Aerospace and Defense:
In aerospace testing, digital panel meters measure resistance in electrical systems or sensors, ensuring components meet stringent performance and safety standards for aircraft or spacecraft.
Benefits of Using Digital Panel Meter Ohmmeters
Digital panel meters for ohmmeter applications offer numerous advantages for resistance measurements:
- High Precision: Accurate ADCs and lead compensation ensure reliable resistance readings across a wide range of values.
- Compact Design: The 1/8 DIN size fits seamlessly into control panels, ideal for space-constrained setups.
- Versatility: Support for multiple resistance ranges and measurement configurations accommodates diverse applications.
- System Integration: Communication interfaces enable connection to automation systems, enhancing data logging and process control.
- Durability: Built to withstand industrial conditions, including dust, moisture, and temperature fluctuations.
- User-Friendly Operation: Intuitive controls and clear displays simplify setup and monitoring, reducing training time.
Choosing the Right Digital Panel Meter Ohmmeter
When selecting a digital panel meter for ohmmeter applications, consider these factors:
- Resistance Range: Ensure the meter supports the resistance values (e.g., micro-ohms to mega-ohms) required for your application.
- Accuracy Specifications: Verify the meter’s accuracy and resolution, especially for low or high resistance measurements.
- Measurement Configuration: Check support for 2-, 3-, or 4-wire configurations to minimize lead resistance errors.
- Environmental Durability: Choose a meter with appropriate IP ratings for dust, water, or temperature resistance in industrial settings.
- Output Requirements: Determine if you need analog outputs, relays, or digital communication for integration with other systems.
- Display and Usability: Opt for a display that’s readable in your environment and controls that are easy to configure.
Conclusion
Digital panel meters for ohmmeter applications, particularly 1/8 DIN models, are vital for precise resistance measurements in industries like electronics manufacturing, automotive testing, and power distribution. Their wide resistance range, high accuracy, and compact design make them ideal for demanding applications. By delivering reliable resistance data and integrating seamlessly with control systems, digital panel meters enhance quality control, support maintenance, and ensure system reliability across diverse resistance measurement tasks.