Features
- Times single or cumulative events from 1 µs to 999,999 hrs
- Transmits single event time or accumulated time of all events
- Timing resolution to 0.2 µs
- Timing from 0.2 µs to 999,999 hrs
- Selectable HH.MM.SS clock format or 6-digit H, M or S decimal format
- Inputs from NPN or PNP proximity switches, contact closures, digital logic, magnetic pickups down to 12 mV, or AC inputs up to 250 Vac
- Triggers on positive or negative pulse edges
- Digital span adjust from 0 to ±999,999, zero adjust from -999,999 to +999,999
- Front panel scalable to ±999,999 for use with current shunts
- 1/8 DIN size with bright red or green 0.56" (14.2mm), high LED digits
- Transducer excitation output, 5, 10, 12, or 24 Vdc (isolated)
- Power 85-264 Vac / 90-300 Vdc or 10-48 Vdc / 12-32 Vac (isolated)
- Operating temperature from -40°C to 70°C (-40°F to 158°F)
- Wide choice of Plug-in-Play options:
- 2 or 4 relays, mechanical or solid state, for alarm or control (isolated)
- 1 or 2 Analog output, 4-20 mA, 0-20 mA, 0-10V, or -10V to +10V (isolated)
- Communications: Ethernet, WiFi, USB, RS232, RS485 (isolated)
- Extended DPM includes rate and total simultaneously, dynamic up-down counting, arithmetic functions
The Laureate™ 1/8 DIN Digital Panel Meter, 6-digit digital stopwatch and timer
can record single or cumulative events ranging from 1 µs to 999,999 hours, with a timing resolution as precise as 0.2 µs. It offers selectable time display formats in HH:MM:SS or 6-digit H, M, or S decimal format, accommodating a variety of measurement needs. Compatible with inputs from NPN or PNP proximity switches, contact closures, digital logic, magnetic pickups as low as 12 mV, and AC inputs up to 250 Vac, it triggers on both positive and negative pulse edges. The device operates on a broad power range of 85-264 Vac / 90-300 Vdc or 10-48 Vdc / 12-32 Vac with (isolated) transducer excitation output. It functions reliably in temperatures from -40°C to 70°C. Additionally, it offers a wide range of options including 2 or 4 relays (mechanical or solid-state, (isolated)), 1 or 2 analog outputs (isolated), and various communication interfaces such as Ethernet, WiFi, USB, RS232, and RS485 (isolated).- A-A Stopwatch Mode. Time can be measured between a start pulse and a stop pulse, both on Channel A, from either the positive or negative edges.
- A-B Stopwatch Mode. Time can also be measured between a start pulse on Channel A (positive or negative edge) and a stop pulse on Channel B (positive or negative edge). This mode allows inputs from different sources. In addition, the A and B inputs can be tied together to start the stopwatch with one polarity and stop it with the other polarity.
- Rate Based on 1/Time Mode. Highly accurate rate can be displayed by taking the inverse of time. Extensive arithmetic capabilities allow display in engineering units, such as meter/sec. This mode requires use of an Extended counter.
Display. The event time (Item #1) may be displayed as a decimal number with six-digit resolution. The longest single-event timing interval is 999,999 hours. The highest resolution is 0.2 µs. The event time may also be displayed in HH.MM.SS clock format with 1 s resolution. The stopwatch display is updated during timing at a rate controlled by a gate time, up to 25/s. It is reset to zero when the next start pulse occurs. Accumulated time from multiple events (Item #2) is also tracked and may be displayed up to 999,999 hours.
The FR dual-channel signal conditioner board accepts inputs from proximity switches with a PNP or NPN output, TTL or CMOS logic, magnetic pickups, contact closures, and other signals from 12 mV to 250 Vac. Jumper selections provide optimum operation for different sensor types and noise conditions. A built-in (isolated) 5, 10, 12, or 24 Vdc excitation supply can power proximity switches and other sensors, and eliminate the need for an external power supply.
Extended DPM includes rate and total simultaneously, dynamic up-down counting, arithmetic functions applicable to channels A & B (A+B, A-B, A/B, AxB, A/B-1), phase angle, power factor, duty cycle, batch control, custom curve linearization.
Laureate Digital Panel Meters are easily programmed with Laurel’s free Instrument Setup Software, downloadable from our website and compatible with Windows PCs, requiring a data interface board for setup.
All signal conditioner board ranges are factory-calibrated, with calibration factors for each range securely stored in an onboard EEPROM. These factors can be scaled via software to accommodate external shunts, enabling field replacement of signal conditioner boards without necessitating recalibration of the associated digital panel meter. For optimal accuracy, factory recalibration is recommended annually. All Laurel Electronics instruments undergo factory calibration using the industry-leading Fluke calibrators, which are recalibrated yearly and certified traceable to national standards, ensuring the highest level of precision and reliability.
- An unfiltered selection provides true peak and valley readings and aids in control applications.
- A batch average filter selection averages each 16 conversions.
- An adaptive moving average filter selection provides a choice of 8 time constants from 80 ms to 9.6 seconds. When a significant change in signal level occurs, the filter adapts by briefly switching to the shortest time to follow the change, then reverts back to its selected time constant. An Auto setting selects the time constant selection based on signal noise.
Peak and valley values are automatically captured. These may be displayed via a front panel pushbutton command or control signal at the rear connector, or be transmitted as serial data.
Two rear panel control Inputs (CMOS/TTL levels, logic 0 = tied to digital ground, logic 1 = open) or dry contacts that can be set to control / activate 14 meter commands.
An (isolated) 5, 10, 12, or 24 Vdc excitation output is standard to power transducers or two-wire transmitters. Ratiometric operation, which automatically compensates for changes in the applied excitation, is jumper selectable for applications, such as bridges, where the signal to be measured is proportional to the excitation level.
Modular Design for Maximum Flexibility at Minimum Cost
All boards are isolated from meter and power grounds. Optional Plug-in-Play boards for communications and control include Ethernet, WiFi, serial communication boards, dual or quad relay boards, and an analog output board. Laureates may be powered from 85-264 Vac or optionally from 12-32 Vac or 10-48 Vdc. The display is available with bright red or green 0.56" (14.2mm) high LED digits. The 1/8 DIN case meets NEMA 4X (IP65) specifications from the front when panel mounted. Any setup functions and front panel keys can be locked out for simplified usage and security. A built-in 5, 10, 12, or 24 Vdc excitation supply can power transducers, eliminating the need for an external power supply. All power and signal connections are via UL / VDE / CSA rated screw clamp plugs.
The Laureate™ Series features modular design with up to 7 isolated plug-in boards, applicable to all Laureate 1/8 DIN Digital Panel Meters.
Modular Hardware
The design of the Laureate™ Series is modular for maximum flexibility at minimum cost. All boards are isolated from meter and power grounds. The base configuration for a panel meter or counter consists of a main module (with computer and plug-in display boards), a power supply board, and a signal conditioner board. Optional plug-in-play boards include an isolated setpoint controller board, an isolated analog output board, and an isolated digital interface board. Modular design and a choice of plug-in options allow the Laureate to be customized for a broad range of applications from simple monitoring to control and computer interface. There can be up to five plug-in boards in a 1/8 DIN Laureate.

Connecting Laureate Digital Panel Meters to a Local Area Network (LAN)
Up to 30 Laureate Digital Panel Meters and/or LT Transmitters can be configured for RS485 and daisy-chained to an LT Transmitter using Laurel’s High Speed Ethernet-to-RS485 converter board for seamless LAN integration. Alternatively, Laurel LTE series Ethernet transmitters can connect directly to a LAN via an Ethernet cable. Setup for both configurations is streamlined using Laurel’s free Instrument Setup Software, which simplifies node discovery and transmitter configuration.
Flexible Communication Options for Digital Panel Meters
Laureate Digital Panel Meters can be equipped with Laurel communication boards to support various interfaces and protocols. These include serial interfaces with ASCII or Modbus RTU protocols, and Ethernet interfaces with web access, ASCII, or Modbus TCP/IP protocols, ensuring versatile connectivity for your commercial applications.
Display | |
---|---|
Readout | 5 LED digits, 7-segment, 14.2 mm (.56"), red or green. |
Range | -999999 to +999999 |
Indicators | Four LED lamps |
Inputs | |
Types | AC, pulses from NPN, PNP transistors, contact closures, magnetic pickups. |
Grounding | Common ground for channels A & B |
Minimum Signal | Nine ranges from (-12 to +12 mV) to (+1.25 to +2.1V). |
Maximum Signal | 250 Vac |
Noise Filter | 1 MHz, 30 kHz, 250 Hz (selectable) |
Contact Debounce | 0, 3, 50 ms (selectable) |
Recalibration: All ranges are calibrated at the factory. Recalibration is recommended every 12 months. | |
Stopwatch Mode | |
Timing Modes: | |
With Ch A only | + to + edge, or - to - edge. |
With Ch A tied to Ch B | + to - edge, or - to + edge. |
With Ch A and Ch B | + edge of A to + edge of B, + edge of A to - edge of B, |
- edge to A to - edge of B, - edge of A to - edge of B | |
Timing Interval | 1 µs to 999,999 hrs |
Timing Resolution | 0.2 µs to 1 hr |
Selectable Decimal Time | 999999 H, M or S format with decimal point |
Selectable Clock Time | HH.MM.SS format |
Output & Display Update | 0 ms + programmable from 10 ms to 199.99 s |
Accuracy | |
Time Base | Crystal calibrated to ±2 ppm |
Span Tempco | ±1 ppm/°C (typ) |
Long-term Drift | ±5 ppm/year |
Power Supply Boards (one required) | |
Voltage, standard | 85-264 Vac or 90-300 Vdc |
Voltage, optional | 12-32 Vac or 10-48 Vdc |
Frequency | DC or 47-63 Hz |
Power Isolation | 250V rms working, 2.3 kV rms per 1 min test |
Excitation Output (standard) | |
5 Vdc | 5 Vdc ± 5%, 100 mA (jumper selectable) |
10 Vdc | 10 Vdc ± 5%, 120 mA (jumper selectable) |
12 Vdc | 12 Vdc ± 5%, 100 mA (jumper selectable) |
24 Vdc | 24 Vdc ± 5%, 50 mA (jumper selectable) |
Output Isolation | 50 Vdc from signal ground |
Analog Output Boards (one optional) | |
Output levels | 4-20 mA, 0-20 mA, 0-10V, -10 to +10V (single-output option) |
4-20 mA, 0-20 mA, 0-10V (dual-output option) | |
Current compliance | 2 mA at 10V ( > 5 kΩ load) |
Voltage compliance | 12V at 20 mA (< 600 Ω load) |
Scaling | Zero and full scale adjustable from -99999 to +99999 |
Resolution | 16 bits (0.0015% of full scale) |
Isolation | 250V rms working, 2.3 kV rms per 1 min test |
(dual analog outputs share the same ground) | |
Relay Output Boards (one optional) | |
Dual magnetic relays | 2 Form C, 8A max, 440Vac or 125Vdc max, 2500VA or 300W |
Quad magnetic relays | 4 Form A (NO), 8A max, 440Vac or 125Vdc max, 2500VA or 300W |
Dual solid state relays | 2 Form A (NO), AC or DC, 0V - 400V, 120Ma, 35Ohms (max at On-State) |
Quad solid state relays | 4 Form A (NO), AC or DC, 0V - 400V, 120Ma, 35Ohms (max at On-State) |
Relay commons | Isolated commons for dual relays or each pair of quad relays |
Relay isolation | 250V rms working, 2.3 kV rms per 1 minute test |
Relay latching modes | Latching or non-latching |
Relay active modes | Active on or off, active high or low |
Hysteresis modes | QA passband mode, split hysteresis, span hysteresis |
Communication Boards (one optional) | |
Board selections | RS232, RS485 with dual RJ11 connectors, RS485 with dual RJ45 connectors, USB, Ethernet, USB-to-RS485 gateway, Ethernet-to-RS485 gateway, WiFi with built-in antenna plus USB & RS485, WiFi with external antenna plus USB & RS485 |
Protocols | Modbus RTU, Modbus ASCII, Modbus TCP (Ethernet), Laurel ASCII |
Data rates | 300 to 19200 baud |
Isolation | 250V rms working, 2.3 kV rms per 1 min test |
Environmental | |
Operating temperature | -40°C to 70°C (-40°F to 158°F) |
Storage temperature. | -40°C to 85°C (-40°F to 185°F) |
Relative humidity | 95% at 40°C, non-condensing |
Protection | NEMA-4X (IP-65) when panel mounted |
Electrical Connections | |
![]() |
|
Mechanical | |
Enclosure | 1/8 DIN, high impact plastic, UL 94V-0, color: black |
Mounting | 1/8 DIN panel cutout required: 3.622" x 1.772" (92 mm x 45 mm). |
Dimensions | 4.68" x 2.45" x 5.64" (119 mm x 62 mm x 143 mm) (W x H x D) |
Maximum panel thickness | 4.5 mm (0.18") |
Tightening Torque - Connectors | Screw terminal connectors: 5 lb-in (0.56 Nm) |
Tightening Torque - Pawls | Digital Panel Meter Case Pawls: 5 lb-in (0.56 Nm) |
Weight of base meter | 210 g (7.4 oz) typical (DPM, counter, timer, 6-digit remote display) |
Weight of option boards | 30 g (1.0 oz) typical per board (analog output, relay output, communications) |
General | |
Programming Methods | Four front panel buttons or via Laurel's free Instrument Setup Software, which runs on a PC under MS Windows. |
Security | Lockout options include using the front panel buttons, the free Instrument Setup Software, or a hardware jumper. |
Warranty | 3 years parts & labor |
Recalibration: All ranges are calibrated at the factory. Recalibration is recommended every 12 months. |
Free Instrument Setup Software for Series 2 Laureates
Free Downloadable Windows-based Instrument Setup (IS) software (Data Interface Board Required) for use with our programmable Digital Panel Meters, Scale Meters, Counters, Timers, Remote Displays, and Transmitters, are an easy method to set up Laureate 1/8 DIN digital panel meters, counters, timers, remote displays, and DIN-rail transmitters, as explained in the Instrument Setup Software Manual. Laureate 1/8 DIN instruments can also be set up from the front panel, as explained in their respective Owners Manuals. Instrument Setup software is of benefit whether or not the PC is connected to the instrument.
- When the PC is connected to the instrument, Instrument Setup software can retrieve the setup file from the instrument or open a default setup file or previously saved setup file from disk View Setup, then provides graphical user interface (GUI) screens with pull-down menus applicable to input, display, scaling, filtering, alarms, communications, analog output, and front panel lockouts. Fields that are not applicable to the instrument as configured are either left out or grayed out. Clicking on any item will bring up a detailed Help screen for that item. After editing, the setup file can be downloaded, uploaded to the instrument, or saved to a disk. The same setup file can then be downloaded into multiple instruments.
- When the PC is not connected to the instrument, the above GUI screens can be used to set up a virtual instrument. The setup file can then be saved to disk. Switching toView Menu then brings up a screen with the required front panel programming steps. This view can be printed out for use at the instrument site and to serve as a hard copy record.
Download Free Instrument Setup Software
Installation
Set User Account Control (UAC) of MS Windows to "Never notifiy me" so that Instrument Setup Software can create directories. The UAC change screen can be reached as follows:
- Under Windows 7, click on the Windows Start button in the lower left of the desktop and enter "UAC" in the search field.
- Under Windows 8, navigate to Control Panel, then to the "User Accounts and Family Safety" section, and click on "Change User Account Control Settings."
- Under Windows 10, click on the Windows Start button in the lower left of the desktop, then on "Settings", and enter "UAC" in the search field.
- Reboot your computer for the changed UAC setting to take effect.

RJ11-to-DB9 cable with rear view of DB9 connector to PC

RS232 cable, meter to PC, P/N CBL01
Laureate 1/8 DIN Laureate instruments must be equipped with a serial communications board and be connected to the computer via a serial communications cable. The connection can be via RS232, RS485, USB or Ethernet. Following setup, the serial communications board may be removed from the instrument if desired. The wiring of the RS232 cable is illustrated above with end views of the two connectors.
Laureate LT Series transmitters come standard with a 3-wire serial interface, which can be jumpered for RS232 or RS485.
Laureate LTE Series transmitters come standard with an Ethernet interface.
Meter Setup Screens
Click on any of the reduced screens below for a full-size screen view, then click on the Back button of your browser to return to this page. The screens examples below are for a fully-loaded Series 2 Digital Panel Meter (DPM), which is connected to the PC via RS232. If the meter is a Series 1 meter (pre-2007), this is sensed by the software, and somewhat different screens are brought up. Please see Series 1 setup screens.











Meter Setup Utilities




From the Main Menu, click on Readings if your PC is connected to the meter. A pull-down menu then offers three choices: List, Plot and Graph.
- List presents the latest readings in a 20-row by 10-column table. Press Pause at any time to freeze the display. This is one method to capture peak readings.
- Plot generates a plot of readings vs. time in seconds. It effectively turns the DPM-PC combination into a printing digital oscilloscope.
- Graph generates a histogram where the horizontal axis is the reading and the vertical axis is the number of occurrences of readings. The display continually resizes itself as the number of readings increases.


Laureate™ 1/8 DIN Case For Laureate Digital Panel Meters, Counters, Timers & Remote Displays

Key Features
- Meets 1/8 DIN Standard.
- Installs from front of panel.
- Short depth behind the panel: only 4" (102 mm) plus connectors.
- Understated 0.157" (4 mm) thick bezel.
- Meets NEMA 4X (IP-65) for high-pressure wawshdon when panel mounted.
- Screw clamps connectors meet VDE / IEC / UL / CSA safety standards.
- Rugged GE Lexan® housing material.
- Safety certified per EN 61010-1.
Dimensions

Maximum panel thickness: 4.5 mm (0.18")
Weight of base meter: 210 g (7.4 oz) typical (DPM, counter, timer, 6-digit remote display)
Weight of option boards: 30 g (1.0 oz) typical per board (analog output, relay output, communications)
Tightening Torque - Connectors: Screw terminal connectors: 5 lb-in (0.56 Nm)
Tightening Torque - Pawls: Digital Panel Meter Case Pawls: 5 lb-in (0.56 Nm)
Dimensioned CAD assembly drawings in EPRT, STEP, x_t. dwg, pdf file formats: Laureate-meter-case.zip (zipping prevents browser from opening CAD files as text files).
Panel Mounting
Slide the meter into a 45 x 92 mm 1/8 DIN panel cutout. Ensure that the provided gasket is in place between the front of the panel and the back of the meter bezel.
The meter is secured by two pawls, each held by a screw, as illustrated. Turning each screw counterclockwise extends the pawl outward from the case and behind the panel. Turning each screw clockwise further tightens it against the panel to secure the meter.
Turning each screw counterclockwise loosens the pawl and retracts it into its well. This position allows installed meter to be removed from their panel, or new meters to be installed in a panel. Do not remove the screws from their pawls. Doing so would cause the screw and pawl to fall off and likely get lost. Do not overtighten so as not to damage the plastic parts.
Stopwatch Mode | |
---|---|
![]() |
The stopwatch mode is used to time single events to one microsecond resolution between start and stop pulses on the same channel. The width of a single waveshape can be measured by tying the A and B channels together. |
Timing Process Dynamics | |
![]() |
The start and stop pulses used for timing can be generated by the dual relay board in a Laureate analog panel meter or digital counter. For instance, the start and stop pulse edges can be created as temperature passes two alarm setpoints, or as temperature cycles in a hysteresis control mode. |
Rate Based on 1 / Time | |
![]() |
The Extended stopwatch meter can be programmed to display highly accurate rate or speed based on time. For example photodetectors on Channels A and B can provide timing pulses as a fast-moving object breaks two light beams, and the meter can then display speed in engineering units such as ft/sec or m/sec. The display will be held until reset by an external control input. |
Replacing an Oscilloscope with a Laureate Meter | |
![]() |
An oscilloscope is great for viewing and timing pulses in a lab. However, in fixed installations where digital timing accuracy and control outputs are required, a low-cost Laureate time interval meter will be the instrument of choice. Resolution to 0.2 µs is feasible. |
Instrumenting a Pulsed Laser System | |
![]() |
|
Some of the many possibilities in instrumenting a pulsed laser system with Laureate dual-channel counters: elapsed time, number of pulses, pulse width, pulse separation, duty cycle, and pulse rep rate. |
IPC
Splashproof Cover
CLB01
RS232 Cable for Meters
CLB02
USB-to-RS232 Adapter Cable
CBL04
RS232 Cable for LT Transmitters
CLB05
USB Data Cable for Meters
CLB06
USB-to-RS485 Adapter Cable
CLB07
USB Programming & Data Cable
CLB08
RS485 Splitter Cable
BKBD
RS485 RJ11 Terminal Block Adapter
What is a Digital Panel Meter for 6-Digit Digital Stopwatch and Timer?
A digital panel meter for 6-digit digital stopwatch and timer applications is a precision instrument designed to measure and display elapsed time or control timed processes with high resolution. These meters function as stopwatches for tracking duration or timers for initiating actions at preset intervals, making them essential in industrial, laboratory, and automation applications where accurate timing is critical, such as in production cycle monitoring, testing, or process control. By providing precise 6-digit readouts, digital panel meters ensure reliable timing data for process optimization, quality assurance, and system efficiency.
Unlike traditional mechanical timers, these digital panel meters offer superior accuracy, programmable features, and integration with modern control systems. The 6-digit display supports high-resolution timing, capable of measuring intervals from milliseconds to hours, making them ideal for applications requiring detailed time tracking or precise control of timed events.
Understanding the Digital Panel Meter for 6-Digit Stopwatch and Timer
Digital panel meters for 6-digit digital stopwatch and timer applications are typically built to the 1/8 DIN standard, fitting compactly into panel cutouts approximately 96 mm x 48 mm. This compact size ensures compatibility with control panels while optimizing space, making them suitable for industrial control rooms, test benches, or equipment with limited space.
These meters are designed to measure elapsed time (stopwatch mode) or control timed processes (timer mode) using internal clocks or external trigger signals, such as pulses from sensors or switches. They feature bright LED or LCD displays, user-friendly interfaces, and communication options like Ethernet or serial interfaces for integration with automation systems. Advanced features, such as programmable timing modes, reset options, and high-resolution counting, ensure reliable performance in demanding environments.
How Does a Digital Panel Meter for 6-Digit Digital Stopwatch and Timer Work?
A digital panel meter processes timing signals or internal clock pulses to measure elapsed time or control timed processes, displaying results with high precision. Below is a detailed breakdown of its operation:
- Signal Acquisition:
In stopwatch mode, the meter starts counting time based on an internal clock or external trigger (e.g., a start/stop signal from a switch). In timer mode, it counts down or up to a preset interval, triggered by internal settings or external inputs. - Signal Conditioning:
External trigger signals are conditioned through filtering or debouncing to ensure accurate detection, critical for reliable timing in environments with electrical or mechanical noise. - Time Measurement:
The meter uses a high-precision internal clock to measure elapsed time (stopwatch) or track progress toward a preset interval (timer). Time is measured in units like milliseconds, seconds, or hours, with 6-digit resolution for fine detail. - Analog-to-Digital Conversion:
A digital counter processes the timing signals into a digital format, ensuring high accuracy for both stopwatch and timer functions. - Processing and Display:
The microcontroller processes the timing data, applying calibration or scaling, and displays results on a 6-digit digital screen with customizable units (e.g., hh:mm:ss, milliseconds). The display may show elapsed time, remaining time, or cycle status. - Output and Integration:
The meter provides outputs like relay contacts for controlling external devices (e.g., starting/stopping equipment), analog signals for feedback, or digital communication for integration with industrial control systems or data loggers. - Calibration and Configuration:
Users can configure the meter for specific timing modes (e.g., stopwatch, up/down timer), set preset intervals, or adjust alarm thresholds, with calibration ensuring accurate timekeeping.
Key Features of Digital Panel Meters for 6-Digit Stopwatch and Timer
Digital panel meters for 6-digit stopwatch and timer applications include features that enhance performance and usability:
- High-Resolution Display: 6-digit displays provide precise timing readouts, supporting measurements from milliseconds to hours.
- Dual Functionality: Supports both stopwatch (elapsed time) and timer (preset interval) modes for versatile applications.
- High Accuracy: Precise internal clocks ensure reliable time measurements, even for long durations or rapid cycles.
- Customizable Displays: Multi-color LEDs or large-digit displays ensure readability in various lighting conditions.
- Programmable Alarms and Control: Setpoints for time intervals trigger alerts or control devices, such as stopping a process at a preset time.
- Communication Options: Support for Ethernet or serial interfaces enables integration with industrial automation systems.
- Rugged Design: Dust- and moisture-resistant front panels ensure durability in harsh industrial environments.
Applications of Digital Panel Meters for 6-Digit Stopwatch and Timer
Digital panel meters are widely used for stopwatch and timer functions in various applications. Key uses include:
- Production Cycle Monitoring:
In manufacturing, DPMs track cycle times for processes like assembly or machining, ensuring consistent production rates. - Batch Timing:
In batch processes, digital panel meters control timing for mixing or curing, triggering actions like valve closure at preset intervals. - Laboratory Testing:
In research labs, DPMs measure elapsed time for experiments, such as chemical reactions or material stress tests, providing accurate timing data. - Equipment Maintenance:
In industrial systems, digital panel meters track equipment run times, supporting predictive maintenance schedules. - Process Automation:
In automated systems, DPMs control timed sequences, such as starting or stopping pumps after specific intervals.
Where Are Digital Panel Meters for 6-Digit Stopwatch and Timer Used?
Digital panel meters are essential in industries requiring precise timing for stopwatch or timer applications. With support for high-resolution timing and a compact design, these meters provide reliable solutions. Below are detailed use cases across key sectors:
- Industrial Manufacturing:
In production lines, digital panel meters track cycle times for processes like welding or packaging, ensuring efficiency and quality control. For example, in an automotive plant, they measure assembly cycle durations. - Food and Beverage Processing:
In food production, DPMs control timing for processes like baking or pasteurization, ensuring consistent product quality and compliance with safety standards. - Chemical Manufacturing:
In chemical plants, digital panel meters manage timing for reactions or mixing processes, triggering actions like stopping pumps at preset intervals. - Scientific and Research Laboratories:
In labs, DPMs measure elapsed time for experiments, such as biological incubations or material fatigue tests, providing accurate timing data for analysis. - Water and Wastewater Treatment:
In treatment facilities, digital panel meters control timed dosing cycles for chemicals, ensuring precise treatment and regulatory compliance. - HVAC and Building Management:
In building systems, DPMs manage timing for HVAC cycles, optimizing energy usage and maintaining comfortable environments. - Automotive and Aerospace Testing:
In test rigs, digital panel meters measure test durations or control timed sequences, ensuring components meet performance standards.
Benefits of Using Digital Panel Meters for 6-Digit Stopwatch and Timer
Digital panel meters offer numerous advantages for stopwatch and timer applications:
- High Precision: Accurate internal clocks and 6-digit resolution ensure reliable timing for short or long intervals.
- Compact Design: The small size fits seamlessly into control panels, ideal for space-constrained setups.
- Versatility: Support for stopwatch and timer modes with programmable settings accommodates diverse applications.
- System Integration: Communication interfaces enable connection to automation systems, enhancing data logging and control.
- Durability: Designed to withstand industrial conditions, including dust, moisture, and temperature fluctuations.
- User-Friendly Operation: Intuitive interfaces and clear displays simplify setup and monitoring, reducing training time.
Choosing the Right Digital Panel Meter for 6-Digit Stopwatch and Timer
When selecting a digital panel meter for 6-digit stopwatch and timer applications, consider these factors:
- Timing Requirements: Ensure the meter supports the required time range (e.g., milliseconds to hours) and modes (stopwatch or timer).
- Accuracy Specifications: Verify the meter’s accuracy and resolution for precise timing measurements.
- Signal Input: Check compatibility with external trigger signals (e.g., switches, sensors) for starting or stopping timing.
- Environmental Durability: Choose a meter with appropriate ratings for dust and moisture resistance in industrial settings.
- Output Requirements: Determine if you need relay outputs, analog signals, or digital communication for integration with other systems.
- Display and Usability: Opt for a 6-digit display that’s readable in your environment and controls that are easy to configure.
Conclusion
Digital panel meters for 6-digit stopwatch and timer applications are vital for precise timing in industries like manufacturing, food processing, and scientific research. Their high-resolution displays, accurate timekeeping, and compact design make them ideal for tracking elapsed time or controlling timed processes. By delivering reliable timing data and integrating seamlessly with control systems, digital panel meters enhance process efficiency, ensure quality, and support system performance across diverse timing applications.
Less Information.