MAGNA Series Serial Input Large Digit Displays accept RS232, RS422 or RS485 serial data from computers, PLCs, transmitters and smart sensors with a serial output. They are digitally addressable and can extract the data to be displayed from within complex data strings. They are ideal for use with economical Laureate Serial Output transmitters, which are available for a wide range of inputs, both analog and pulsed. Please see the next section.
Viewing distances up to 320 feet (100 m) are achieved with oversize digits. A rule of thumb is that viewing distance in feet is 40 times digit height in inches, or in metric terms, that viewing distance in meters is digit height in millimeters divided by 2.
Four digit heights are available: 57 mm (2-1/4"), 102 mm (4.0"), 150 mm (5.9"), and 200 mm (7.9"). Solid segments are used for normal brightness 2.2" and 4.0" digits. Individual 5 mm LED pixels are used for larger digits and outdoor brightness versions. The number of digits can be 4 or 6.
Indoor or Outdoor Viewing: MAGNA Series Displays with normal brightness LEDs can be read across an entire plant floor to keep workers informed without leaving their work area. Displays with outdoor brightness LEDs can be read across an industrial yard, parking lot or roadway, for example to display vehicle load. Available mounting options are panel mount, wall mount and suspension mount. Environmental sealing to IP65 (NEMA-4X) is standard.
Options include two or four 2A relays, an analog output, an RS232 or RS485 serial data output, and 95-264 Vac or 11-30 Vdc power.
Intuitive Setup is normally provided by means of built-in front panel switches, which can be locked. It is also possible to remotely wire four pushbuttons to the display.
Serial data input board
Serial data output boards
Relay output boards
Analog output boards
Approvals | |
---|---|
Types | Produced to IPC 610 Class 2 Standard UL ISO9001:2008 QA |
Serial Data Input | |
Serial Data Types | RS232 or RS485 (specify at time of order) |
Serial Connector | Detachable plug-in screw terminals |
Displayed Information | ASCII: Displays any character within 7-segment display limitations. |
Quant: Displays only numeric ASCII values. | |
Qa.Tot: Quantity totalizer. Can be used to accumulate weight values, for example after each batch. Uses a contact closure to trigger addition. | |
Settable Parameters | |
Baud Rate | 300 to 115200 |
Data Format | 701, 7e1, 7n2, 801, 8e1, 8n1, 8n2 |
Termination Character | Hex 00 to FF |
Reject Characters | Counted from termination character |
Addressing | 00 (wildcard) to F7 |
Display | |
Number of Digits | 4 or 6 |
Digit Height | 57 mm (2-1/4"), 102 mm (4.0"), 150 mm (5.9"), or 200 mm (7.9") |
Digit Color | Red |
Brightness | Variable |
Decimal Format | 8.8.8.8. or 8.8.8.8.8.8. (standard) |
Clock Format | HH:MM or HH:MM:SS (optional, specify at time of order) |
Display Update Rate | 10 readings/second |
Logic Inputs | |
Front Panel Controls | Four buttons to set time, date, alarms, etc. |
Logic Functions | Three logic inputs, individually configurable for Hold, Reset, Tare, Peak / Valley, Net/Gross, Memory Address. |
Logic Levels | Normally open, NPN or contact closure input to activate. 5V open circuit, 1 mA switched current. |
Power | |
AC Power (standard) | 100-240 Vac |
DC Power (option) | 11-30 Vdc |
Max Consumption | 30 VA |
Analog Output Option | |
Output Levels | 0-20 / 4-20 mA into 0 to 500Ω, 0.4 µA resolution. |
0-10V into loads > 600Ω, 0.2 mV resolution. | |
-10 to +10V into loads > 600Ωs, 0.4 mV resolution. | |
Resolution | 16 bits |
Accuracy | 0.1% of range |
Stability | 50 ppm/°C |
Output Isolation | Isolated from input and power |
Scaling | Digitally scalable |
Special Features | Forward or reverse action possible. |
Can be set to operate from net or gross value. | |
Alarm Output Option | |
Relay Type | Two or four relays rated 2A, 250VAC, SPDT |
Special Features | Adjustable hysteresis |
Logic Levels | Normally open, NPN or contact closure input to activate. 5V open circuit, 1 mA switched current. |
Power | |
AC Power (standard) | 100-240 Vac |
DC Power (option) | 11-30 Vdc |
Max Consumption | 30 VA |
Analog Output Option | |
Output Levels | 0-20/4-20 mA into 0 to 500Ω, 0.4 μA resolution. 0-10V into loads > 600Ω, 0.2 mV resolution. -10 to +10V into loads > 600Ω, 0.4 mV resolution. |
Resolution | 16 bits |
Accuracy | 0.1% of range |
Stability | 50 ppm/°Cl |
Output Isolation | Isolated from input and power |
Scaling | Digitally scalable |
Special Features | Can be set to operate from net or gross value. |
Alarm Output Option | |
Relay Type | Two or four relays rated 2A, 250VAC, SPDT |
Special Features | Adjustable hysteresis |
In-flight compensation facility. | |
Energize or de-energize on trip. | |
Adjustable timers to set energize and de-energize delays. Can also be set to pulse for applications needing less than 100% duty cycle. | |
In-band and out-of-band alarm function. | |
Manual and automatic in-flight compensation. | |
Can be set to operate from net or gross value. | |
Serial Data Output Option | |
Output Types | RS232 or RS485, addressable, on demand or continuous output. |
Special Features | Can include time and date with RTC option fitted. Can be set to operate from net or gross value. |
Environmental | |
Storage Temp. | -20°C to +70°C |
Operating Temp. | 0°C to 50°C, non-condensing. -25°C to 50°C, non-condensing, with MHTR AC heater option. |
Sealing | IP65 standard, all-round |
Connections | M12 compression glands for round cable, diameter 3.0 to 6.5 mm (0.118" to 0.256") |
Mounting | Wall mount, suspension mount, panel mount |
Display Format | ![]() |
![]() |
Case width x height | 4 Digits | 6 Digits |
---|---|---|
57 mm (2.2") digits | 279 x 155 mm (11.0" x 6.1") | 376 x 155 mm (14.8" x 6.1") |
102 mm (4.0") digits | 434 x 196 mm (16.7" x 7.7") | 616 x 196 mm (24.3" x 7.7") |
150 mm (5.9") digits | 514 x 247 mm (20.2" x 9.8") | 744 x 248 mm (29.3" x 9.8") |
200 mm (7.9") digits | 664 x 298 mm (26.1" x 11.7") | 984 x 298 mm (38.7" x 11.7") |
Case depth | 75 mm (3.0") |
Note: | Models with 57 mm (2.2") digits, 4 digits and 4 relays require the larger 6-digit case. For panel mount versions, add 18 mm (0.7") to case width and height for the bezel and 25 mm (1.0") for cable glands in back of the case. |