MAGNA Series Counter / Totalizer Input Large Digit Displays accept frequencies from 0 to 40 kHz. They accept most common industrial pulse inputs, namely contact closures, NPN or PNP proximity sensors, 5V logic pulses, 24V PLC pulses, and quadrature encoders. The units are easily scaled to display totals in engineering units such as feet, meters, gallons, or tons. An isolated 24V excitation output is standard to power active sensors and encoders. In totalizer mode, the meter can add together and scale counts from up to 4 independent input signals.
Viewing distances up to 320 feet (100 m) are achieved with 8" digits. A rule of thumb is that viewing distance in feet is 40 times digit height in inches, or in metric terms, that viewing distance in meters is digit height in millimeters divided by 2.
Four digit heights are available as standard: 57 mm (2-1/4"), 102 mm (4.0"), 150 mm (5.9"), and 200 mm (7.9"). Solid segments are used for normal brightness 2.2" and 4.0" digits. Individual 5 mm LED pixels are used for larger digits and outdoor brightness versions. The number of digits can be 4 or 6.
Indoor or outdoor viewing: MAGNA Series Displays with normal brightness LEDs can be read over a machine or across a plant floor. Displays with outdoor brightness LEDs can be read across an industrial yard, parking lot or roadway, for example to display vehicle load. A heater option allows outdoor operation in winter in cold climates. Available mounting options are panel mount, wall mount and suspension mount. Environmental sealing to IP65 (NEMA-4X) is standard.
Standard options include two or four 2A relays, an analog output, an RS232 or RS485 serial data output, and 95-264 Vac or 11-30 Vdc power.
Intuitive setup is normally provided by means of built-in front panel switches, which can be locked. It is also possible to remotely wire four pushbuttons to the display.
Pulse input board
Serial data output boards
Relay output boards
Analog output boards
Approvals | |
---|---|
Types | Produced to IPC 610 Class 2 Standard |
UL ISO9001:2008 QA | |
Pulse Inputs | |
Number of Inputs | 4 |
Signal Types | Configurable for contact closures, NPN or PNP proximity switches, 5V logic pulses, 24V pulses, quadrature |
Frequency Range | 0-40 kHz in totalizing mode |
Debounce | Programmable to eliminate false counting from contact bounce. |
Display | |
Number of Digits | 4 or 6 |
Digit Height | 57 mm (2-1/4"), 102 mm (4.0"), 150 mm (5.9"), or 200 mm (7.9") |
Digit Color | Red |
Brightness | Variable |
Numeric Format | 8.8.8.8. or 8.8.8.8.8.8. |
Display Update Rate | 3 readings/second above 3 Hz, otherwise signal pulse rate. |
User Controls | |
Scaling | Digital direct or theoretical scaling with scale & offset. |
Filtering | Digital filtering, time constants adjustable from 0 to 25 sec. |
Rounding | Selectable last-digit rounding of 1, 2, 5, 10, 20, 50 units. |
Linearization | Up to 10 points, direct or theoretical calibration. |
Logic Inputs | |
Front Panel Controls | Four buttons to set time, date, alarms, etc. |
Logic Functions | Three logic inputs, individually configurable for Hold, Reset, Tare, Peak / Valley, Net/Gross, Memory Address. |
Logic Levels | Normally open, NPN or contact closure input to activate. 5V open circuit, 1 mA switched current. |
Power | |
AC Power (standard) | 100-240 Vac |
DC Power (option) | 11-30 Vdc |
Max Consumption | 30 VA |
Analog Output Option | |
Output Levels | 0-20 / 4-20 mA into 0 to 500Ω, 0.4 µA resolution. |
0-10V into loads > 600Ω, 0.2 mV resolution. | |
-10 to +10V into loads > 600Ω, 0.4 mV resolution. | |
Resolution | 16 bits |
Accuracy | 0.1% of range |
Stability | 50 ppm/°C |
Output Isolation | Isolated from input and power |
Scaling | Digitally scalable |
Special Features | Forward or reverse action possible. |
Can be set to operate from net or gross value. | |
Alarm Output Option | |
Relay Type | Two or four relays rated 2A, 250VAC, SPDT |
Special Features | Adjustable hysteresis |
Energize or de-energize on trip. | |
Adjustable timers to set energize and de-energize delays. Can also be set to pulse for applications needing less than 100% duty cycle. | |
In-band and out-of-band alarm function. | |
Manual and automatic in-flight compensation. | |
Can be set to operate from net or gross value. | |
Serial Data Output Option | |
Output Types | RS232 or RS485, addressable, on demand or continuous output. |
Special Features | Can include time and date with RTC option fitted. |
Can be set to operate from net or gross value. | |
Environmental | |
Storage Temp. | -20°C to +70°C |
Operating Temp. | 0°C to 50°C, non-condensing. -25°C to 50°C, non-condensing, with MHTR AC heater option. |
Sealing | IP65 (NEMA4) standard, all-round |
Connections | M12 compression glands for round cable, diameter 3.0 to 6.5 mm (0.118" to 0.256") |
Mounting | Wall mount, suspension mount, panel mount |
Display Format | ||
Digit Height | 4 Digits | 6 Digits |
---|---|---|
57 mm (2.2") | 280 x 155 mm (11.0" x 6.1") | 376 x 155 mm (14.8" x 6.1") |
102 mm (4.0") | 434 x 196 mm (17.1" x 7.7") | 616 x 196 mm (24.3" x 7.7") |
150 mm (5.9") | 580 x 247 mm (22.8" x 9.8") | 820 x 247 mm (32.3" x 9.8") |
200 mm (7.9") | 750 x 290 mm (29.5" x 11.4") | 1072 x 290 mm (42.2" x 11.4") |
Case depth | 75 mm (3.0") |
Note: | Models with 57 mm (2.2") digits, 4 digits and 4 relays require the larger 6-digit case. For panel mount versions, add 18 mm (0.7") to case width and height for the bezel and 25 mm (1.0") for cable glands in back of the case. |
Click on the radio buttons to build a standard model number with pricing (shown below the Ordering Guide). Prices are in US dollars and do not include shipping or duty charges (export sales). Please see our explanations and limitations applicable to pricing and online orders.
Prices shown are in US Dollars and are Laurel's manufacturer's suggested retail price (MSRP) in the USA. Orders are processed manually, not directly by our shopping cart system. You don't have to supply credit card information when placing an online order.
North American Orders. Laurel does not sell factory-direct in the USA or Canada. Online sales orders are filled through distribution. During the ordering process, you will have the chance to select an authorized Laurel distributor, or you can ask Laurel to refer you to a distributor. The distributor will then contact you to quote shipping, tax and duty (where applicable), and arrange for payment.
International Orders. If your ship-to address indicates that you are outside of the USA or Canada and Laurel has a distributor in your country, we will forward your order to that distributor for follow-up. If Laurel does not have a distributor in your country, we will email you an order acknowledgment and a pro forma invoice which states the product price, shipping charges, and wire transfer information, which includes a $25 bank wire transfer fee.
Questions about your order? Please email your distributor or sales@laurels.com
MAGNA units are built to order. MAGNA orders are non-cancelable and non-returnable.
Customized large digit displays are available by special quotation: