The Laureate Series Programmable Digital Panel Meters feature a modular design, offering maximum flexibility at a minimal cost. All boards are isolated from meter and power grounds. The base configuration for a digital panel meter, digital counter, or digital timer consists of a main module (with computer and plug-in display boards), a power supply board (Vac or Vdc), and a signal conditioner board. Optional plug-in boards include setpoint controller boards, analog output boards, and digital interface boards. Read more...

Industrial Electronic Digital Timers

6-Digit Digital Stopwatch and Timer

Time Base Crystal calibrated to ±2 ppm Span tempco ±1 ppm/°C (typ)
Long-term Drift ±5 ppm/year (typ)

$325.00

Time Interval of Periodic Events

Time Base Crystal calibrated to ±2 ppmSpan tempco ±1 ppm/°C (typ)
Long-term Drift ±5 ppm/year (typ)

$325.00

Duty Cycle and (PWM) 

Time Base Crystal calibrated to ±2 ppmSpan tempco ±1 ppm/°C (typ)
Long-term Drift ±5 ppm/year (typ)

$366.00

Serial Input 6-Digit Remote Display

Display from -999,999 to +999,999
High read rates at up to 60 or 50 conversions per second.

    $325.00

    Electronic Timers for Industrial Event and Interval Timing

    Electronic timers are panel-mounted digital instruments built around one job: measuring elapsed time rather than a signal value or a pulse count. A panel meter reads voltage or temperature, a counter totalizes pulses, and a timer instead captures the duration between two events — a single interval, an accumulated total across repeated cycles, the period of a recurring event, or the on/off ratio of a pulse-width-modulated signal. Laurel's timers sit on the same 1/8 DIN modular platform as its meters and counters, with a 6-digit LED display, a crystal time base calibrated to ±2 ppm, and the same plug-in board architecture, so a high-resolution timing instrument fits on the same panel and uses the same setup software as the rest of an instrument line.

    Timer Configurations

    • 6-digit stopwatch and timer: Times a single interval from a start trigger to a stop trigger, with applications from production cycle timing to lab experiment tracking.
    • Time interval of periodic events: Measures the duration of a recurring, repeating cycle — suited to continuous operations such as conveyor or indexing systems where cycle consistency matters.
    • Duty cycle and PWM: Analyzes a pulse-width-modulated signal up to 1 MHz, displaying the on/off ratio as a percentage, used in motor control and LED dimming applications.
    • Serial input 6-digit remote display: Receives data over RS-232, RS-485, or Modbus and displays it as a remote readout, from -999,999 to +999,999.

    Specifications Common to the Line

    • Time base: Crystal calibrated to ±2 ppm, with ±1 ppm/°C temperature coefficient and ±5 ppm/year long-term drift.
    • Display: 6-digit LED with customizable scaling.
    • Construction: Modular, with isolated boards throughout.
    • Expandability: Optional plug-in relays, analog outputs, and digital communication interfaces.

    Where Electronic Timers Are Used

    • Production cycle timing: Capturing how long a stage of a process takes, cycle to cycle.
    • Continuous operations monitoring: Timing recurring cycles on conveyor and indexing systems to flag drift from the expected rhythm.
    • Motor and LED control: Verifying duty cycle on PWM-driven motors and dimming circuits is operating at the intended level.
    • Remote and networked display: Using the serial input configuration as a large, clear readout for a value computed elsewhere.
    • Lab and test bench timing: Capturing precise event durations during experiments or equipment testing.

    Electronic Timer Frequently Asked Questions

    What's the difference between an electronic timer and an electronic counter?

    A counter processes a pulse train, counting pulses or computing a rate from their frequency. A timer instead measures duration — the elapsed time between two events, whether a single interval, an accumulated total, or a repeating cycle period. A counter answers "how many" or "how fast"; a timer answers "how long."

    Can the stopwatch/timer configuration accumulate time across multiple start/stop cycles, or only time one interval?

    It can do either, depending on configuration — single event timing captures one interval from a start signal to a stop signal, while accumulated event timing sums duration across multiple repeated start/stop cycles into a running total.

    How is time interval of periodic events different from basic stopwatch timing?

    Basic stopwatch timing captures a single, typically non-repeating interval. Periodic event timing measures the duration of a recurring cycle — the time between one occurrence of a repeating event and the next — which is built for monitoring the rhythm or consistency of an ongoing process rather than a one-off measurement.

    What frequency range does the duty cycle/PWM configuration cover?

    This configuration analyzes pulse-width-modulated signals up to 1 MHz, computing the on/off ratio as a duty cycle percentage, which covers the PWM frequencies typically used in motor speed control and LED dimming circuits.

    What is the serial input remote display configuration actually for?

    It's a 6-digit display that receives its value over a serial connection (RS-232, RS-485, or Modbus) from another device rather than measuring a signal itself, functioning as a large, clear remote readout for a value another instrument or controller has already computed, from -999,999 to +999,999.

    Can a timer trigger an alarm or control output based on elapsed time?

    Yes, with the appropriate option board. A timer can drive relay outputs from configurable time-based setpoints and retransmit its reading as an analog output, serving as both an indicator and a simple time-based controller.

    How precise is the timing resolution on these instruments?

    Resolution depends on the specific configuration, but single and accumulated event timing on these platforms can resolve intervals down to a fraction of a microsecond, supporting applications from basic process timing to capturing very short, fast events.

    Are these timers suited to continuous, 24/7 operations like conveyor systems?

    Yes — the periodic event timing configuration in particular is built for exactly that kind of continuous, repeating-cycle monitoring, where consistent, drift-free timing matters over long, uninterrupted runs rather than a single isolated measurement.

    Electronic Timer Questions From the Field

    My accumulated timer's total doesn't match what I'd expect from counting cycles manually — what should I check?

    Confirming the start and stop trigger conditions (such as signal edge or logic level) are configured to match exactly what the connected sensor or switch actually outputs is the first step, since a mismatch between the expected and actual trigger condition can cause extra or missed start/stop events that accumulate into an incorrect total over time.

    My conveyor's periodic event timer shows cycle times drifting slightly over a long run — is that expected?

    Some cycle-to-cycle variation is expected if the mechanical process itself isn't perfectly consistent, since the timer accurately reports real variation rather than introducing its own error; if the drift seems larger than the process itself should produce, checking for signal noise or a marginal trigger threshold on the input is the standard next step.

    My duty cycle reading on a motor control circuit doesn't match what I'm seeing on a scope — what should I check?

    Confirming both instruments are measuring the same point in the circuit and using the same definition of "on" (active-high vs. active-low) is the first step, since a duty cycle calculation depends entirely on which signal transitions are being counted as the start and end of the "on" period.

    My serial-input remote display shows a frozen or stale value — what should I check?

    Confirming the sending device is still actively transmitting on the expected serial protocol and address is the first step, since a remote display configuration shows whatever it last received and has no way to know the data source has stopped updating.

    My timer's relay isn't triggering at the time setpoint I configured — what should I check?

    Confirming the setpoint value and relay mode (normally open vs. normally closed) are configured as intended is the first step, since a relay that appears not to trigger is often configured correctly but for a different condition than expected.

    My single-event timing reading seems to include extra time I didn't expect — what should I check?

    Confirming the exact start and stop trigger points match where the physical event actually begins and ends is the first step, since an event timer measures precisely between its configured triggers, and a trigger set slightly before the true start or after the true end will add that extra time into the reading even though the timer itself is functioning correctly.

    My PWM duty cycle reading jumps around at higher frequencies close to the 1 MHz limit — what should I check?

    Confirming the signal being measured isn't degraded by cable length, noise, or signal rise/fall time limitations at that frequency is the first step, since signal integrity becomes more critical as frequency approaches the upper end of the instrument's rated range.