MAGNA Series Large Digit Clocks & Timers

Features
- Choice of 2-1/4", 4", 6" or 8" digit heights
- Choice of 4 or 6 digits with colon dividers
- Choice of normal or outside viewing brightness
- Choice of RS232 or RS485 serial data input
- Choice of panel mount, wall mount or suspension mount
- Choice of 95-264 Vac or 11-30 Vdc power
- Sealed to NEMA-4 (IP65)
- Only 3.0" (75 mm) deep
- Programmable from front panel
- Optional two or four 2A relay outputs, analog output, serial I/O
MAGNA Series Clock & Timer Large Digit Displays can serve as accurate time-of-day clocks that are visible across a factory floor. Typical accuracy is within two minutes per year. By using the optional serial data output, a single clock display can feed up to 32 synchronized slave displays around the factory.
MAGNA Series Clock & Timer Large Digit Displays can also serve as highly accurate count-up or count-down timers. A battery-backed quartz crystal clock chip provides excellent long-term stability. Start and stop signals can be proved by common industrial pulse inputs, such as contact closures, NPN or PNP proximity sensors, 5V logic pulses, or 24V PLC pulses.
Viewing distances up to 320 feet (100 m) are achieved with 8" digits. A rule of thumb is that viewing distance in feet is 40 times digit height in inches, or in metric terms, that viewing distance in meters is digit height in millimeters divided by 2.
Four digit heights are available as standard: 57 mm (2-1/4"), 102 mm (4.0"), 150 mm (5.9"), and 200 mm (7.9"). Solid segments are used for normal brightness 2.2" and 4.0" digits. Individual 5 mm LED pixels are used for larger digits and outdoor brightness versions. Clock displays are available with 4 or 6 digits for a HH:MM or HH:MM:SS display with colon dividers.
Indoor or outdoor viewing: MAGNA Series Displays with normal brightness LEDs can be read over a machine or across a plant floor. Displays with outdoor brightness LEDs can be read across an industrial yard, parking lot or roadway, for example to display vehicle load. A heater option allows outdoor operation in winter in cold climates. Available mounting options are panel mount, wall mount and suspension mount. Environmental sealing to IP65 (NEMA-4X) is standard.
Options available include two or four 2A relays, an analog output, an RS232 or RS485 serial data output, and 95-264 Vac or 11-30 Vdc power.
Intuitive setup is normally provided by means of built-in front panel switches, which can be locked. It is also possible to remotely wire four pushbuttons to the display.
Standard Large Digital Displays are available here. Prices are in US dollars and do not include shipping or duty charges (export sales).
Questions about your order? Please email our support@laurels.com
MAGNA units are built to order. MAGNA orders are non-cancelable and non-returnable.
Customized large digit displays are available by special quotation:
- LED colors green, blue, white, yellow (not limited to red).
- Digit heights of 12", 16", 24" or 32" (not just4", 6" or 8").
- 2 or 4 solid state relays (not just mechanical relays).
- Stainless steel housing (for food processing and pharmaceutical industries).
- Explosion-proof stainless steel housing rated for ATEX Zones 2 and 22 (equivalent to Class1 / Div 2).
- Custom signs with different colors, with fixed captions, and with multiple numeric display windows.
Pulse input board
Serial data output boards
Relay output boards
Analog output boards
Approvals | |
---|---|
Types | Produced to IPC 610 Class 2 Standard |
UL ISO9001:2008 QA | |
Time Base | |
Time Reference | Precision, temperature-compensated quartz crystal. |
Display | |
Number of Inputs | 4 or 6 |
Digit Height | 57 mm (2-1/4"), 102 mm (4.0"), 150 mm (5.9"), or 200 mm (7.9") |
Digit Color | Red |
Brightness | Variable |
Clock Format | HH:MM or HH:MM:SS |
Logic Inputs | |
Front Panel Controls | Four buttons to set time, date, alarms, etc. |
Logic Functions | Three logic inputs, individually configurable for Hold, Reset, Tare, Peak / Valley, Net/Gross, Memory Address. |
Logic Levels | Normally open, NPN or contact closure input to activate. 5V open circuit, 1 mA switched current. |
Power | |
AC Power (standard) | 100-240 Vac |
DC Power (option) | 11-30 Vdc |
Max Consumption | 30 VA |
Analog Output Option | |
Output Levels | 0-20 / 4-20 mA into 0 to 500Ω, 0.4 µA resolution. |
0-10V into loads > 600Ω, 0.2 mV resolution. | |
-10 to +10V into loads > 600Ω, 0.4 mV resolution. | |
Resolution | 16 bits |
Accuracy | 0.1% of range |
Stability | 50 ppm/°C |
Output Isolation | Isolated from input and power |
Scaling | Digitally scalable |
Special Features | Forward or reverse action possible. |
Can be set to operate from net or gross value. | |
Alarm Output Option | |
Relay Type | Two or four relays rated 2A, 250VAC, SPDT |
Special Features | Adjustable hysteresis |
Energize or de-energize on trip. | |
Adjustable timers to set energize and de-energize delays. Can also be set to pulse for applications needing less than 100% duty cycle. | |
In-band and out-of-band alarm function. | |
Manual and automatic in-flight compensation. | |
Can be set to operate from net or gross value. | |
Serial Data Output Option | |
Output Types | RS232 or RS485, addressable, on demand or continuous output. |
Special Features | Can include time and date with RTC option fitted. |
Can be set to operate from net or gross value. | |
Environmental | |
Storage Temp. | -20°C to +70°C |
Operating Temp. | 0°C to 50°C, non-condensing. -25°C to 50°C, non-condensing, with MHTR AC heater option. |
Sealing | IP65 (NEMA4) standard, all-round |
Connections | M12 compression glands for round cable, diameter 3.0 to 6.5 mm (0.118" to 0.256") |
Mounting | Wall mount, suspension mount, panel mount |
Number of Digits & Case Dimensions

Display Format | ![]() |
![]() |
Digit Height | 4-Digit Case Width x Height | 6-Digit Case Width x Height |
---|---|---|
57 mm (2.2") | 280 x 155 mm (11.0" x 6.1") | 376 x 155 mm (14.8" x 6.1") |
102 mm (4.0") | 434 x 196 mm (16.7" x 7.7") | 616 x 196 mm (24.3" x 7.7") |
150 mm (5.9") | 580 x 247 mm (22.8" x 9.7") | 820 x 247 mm (32.3" x 9.7") |
200 mm (7.9") | 750 x 290 mm (29.5" x 11.7") | 1072 x 290 mm (42.2" x 11.7") |
Case depth | 75 mm (3.0") |
Note: | Models with 57 mm (2.2") digits, 4 digits and 4 relays require the larger 6-digit case. For panel mount versions, add 18 mm (0.7") to case width and height for bezel and 25 mm (1.0") for cable gland in back of case. |

Number of Digits & Case Dimensions

Display Format | ![]() |
![]() |
Digit Height | 4-Digit Case Width x Height | 6-Digit Case Width x Height |
---|---|---|
57 mm (2.2") | 280 x 155 mm (11.0" x 6.1") | 376 x 155 mm (14.8" x 6.1") |
102 mm (4.0") | 434 x 196 mm (16.7" x 7.7") | 616 x 196 mm (24.3" x 7.7") |
150 mm (5.9") | 580 x 247 mm (22.8" x 9.7") | 820 x 247 mm (32.3" x 9.7") |
200 mm (7.9") | 750 x 290 mm (29.5" x 11.7") | 1072 x 290 mm (42.2" x 11.7") |
Case depth | 75 mm (3.0") |
Note: | Models with 57 mm (2.2") digits, 4 digits and 4 relays require the larger 6-digit case. For panel mount versions, add 18 mm (0.7") to case width and height for bezel and 25 mm (1.0") for cable gland in back of case. |

MAGNA Large Digit Displays
- MAGNA Process Signal (4-20 mA, 0-10V) Input Manual: 45 pages, 0.5 MB
- MAGNA Clock-Timer Manual: 31 pages, 0.4 MB
- MAGNA Strain Gauge & Load Cell Input Manual: 45 pages, 0.5 MB
- MAGNA RS232 & RS485 Data Serial Data Input Manual: 36 pages, 0.4 MB
- MAGNA Totalizer & Rate Meter Manual: 47 pages, 0.5 MB
- MAGNA Thermocouple & RTD Input Manual: 45 pages, 0.5 MB
- MAGNA Alarm Options Manual: 32 pages, 0.25 MB
- MAGNA Analog Output Options Manual: 12 pages, 0.1 MB
- MAGNA Serial Output Options Manual: 18 pages, 0.2 MB