Digital Panel Meter for Batch Controller Pulse Input Applications P/N L81106FR

Digital Panel Meter for Batch Controller Pulse Input Applications

Price: $642.00
  • P/NL81106FR
- +

Features

  • Provides automatic control for repetitive liquid fill operations
  • Available for turbine flow meter pulse signals from 0 Hz to 1 MHz or analog flow meter signals (4-20 mA, 0-1 mA or 0-10V)
  • 6-digit scalable display to ±999,999 for batch total, grand total, number of batches, or flow rate
  • Counts up from 0 to preset or down from preset to 0
  • Two or four control relays for with settable delay between cycles
  • Digital span adjust from 0 to ±999,999, zero adjust from -999,999 to +999,999
  • Front panel scalable: to ±999,999 for use with current shunts
  • 1/8 DIN size with bright red or green 0.56" (14.2mm), high LED digits
  • Transducer excitation output, 5, 10, 12, or 24 Vdc (isolated)
  • Power 85-264 Vac / 90-300 Vdc or 10-48 Vdc / 12-32 Vac (isolated)
  • Operating temperature from -40°C to 70°C  (-40°F to 158°F)
  • Wide choice of Plug-in-Play options:
    - 2 or 4 relays, mechanical or solid state, for alarm or control (isolated)
    - 1 or 2 Analog output, 4-20 mA, 0-20 mA, 0-10V, or -10V to +10V (isolated)
    - Communications: Ethernet, WiFi, USB, RS232, RS485 (isolated)

The Laureate™ 1/8 DIN Digital Panel Meter batch controller

is a low cost, powerful and highly accurate batching controller for repetitive fill operations. It can use the Laureate FR dual channel pulse input signal conditioner for use with turbine flow meters. Relay control can be provided by two or four 8A contact relays, or by two or four 120 mA AC/DC solid state relays. Fill operations are repeated continually with a programmable delay from 10 ms to 199.99 sec, or based on an external control input.

Three items are tracked by the batch control software. These can each be scaled to engineering units of total or flow rate and displayed by the controller's six-digit LED display: Item #1 is the current batch total, which can be set up to count up from zero to a preset limit, or down from a preset limit to zero. Item #2 can be assigned to grand total or number of batches. Item #3 is the flow rate.

The Laureate Digital Panel Meter is easily programmed with Laurel’s free Instrument Setup Software, downloadable from our website and compatible with Windows PCs, requiring a data interface board for setup.

All signal conditioner board ranges are factory-calibrated, with calibration factors for each range securely stored in an onboard EEPROM. These factors can be scaled via software to accommodate external shunts, enabling field replacement of signal conditioner boards without necessitating recalibration of the associated digital panel meter. For optimal accuracy, factory recalibration is recommended annually. All Laurel Electronics instruments undergo factory calibration using the industry-leading Fluke calibrators, which are recalibrated yearly and certified traceable to national standards, ensuring the highest level of precision and reliability.

Two or four relays can be used. Relay #1 is assigned to batch total to control the filling operation. Relays #2, #3 and #4 can each be assigned by the user to Items #1, #2 or #3. For example, Relay #2 can be assigned to Item #1 (batch total) with a lower setpoint to serve as a pre-warn and slow down the fill rate near the batch setpoint, and Relay #3 can be assigned to the total number of batches to terminate the batching when a present number of bottles have been filled.

An optional serial communications board allows the batch controller to transmit Items #1, #2 and #3, as well as peak for item #3 (rate). If required, all four items can be displayed simultaneously by augmenting the batch controller with up to three Laureate remote displays. Each of these can have its own analog output and relays for alarm or control.

Batch Control with Turbine Flowmeters

The pulse-input batch controller utilizes the FR dual channel signal conditioner, which accepts pulses from turbine flow meters and most industrial transducers with a pulse output such as proximity switches with PNP or NPN output, TTL or CMOS logic, or magnetic pickup pulses down to 12 mV. The same signal is applied in parallel to the A and B input channels, which are used independently. Either channel can accept pulse rates from 0.005 Hz to 250 kHz, which exceeds the working range of turbine flow meters.

  • Channel A is used for totalizing. The measured total is scaled mathematically for control and display of volume in engineering units, such as liters.
  • Channel B is used for rate. The pulse frequency is determined by timing an integral number of periods over a specified gate time (plus 30 ms and 0-2 periods), and then taking the inverse of period. The inverse period approach allows much greater accuracy and faster update times than conventional rate meters which count signal pulses over a specified time interval. Update times can be as high as 25/sec. Rate in engineering units, such as liters per second, is obtained by multiplying the input by a scale factor.
Digital signal filtering modes can be selected to ensure stable readings in electrically noisy environments.
  • An unfiltered selection provides true peak and valley readings and aids in control applications.
  • A batch average filter selection averages each 16 conversions.
  • An adaptive moving average filter selection provides a choice of 8 time constants from 80 ms to 9.6 seconds. When a significant change in signal level occurs, the filter adapts by briefly switching to the shortest time to follow the change, then reverts back to its selected time constant. An Auto setting selects the time constant selection based on signal noise.

Peak and valley values are automatically captured. These may be displayed via a front panel pushbutton command or control signal at the rear connector, or be transmitted as serial data.

Two rear panel control Inputs (CMOS/TTL levels, logic 0 = tied to digital ground, logic 1 = open) or dry contacts that can be set to control / activate 14 meter commands.

An (isolated) 5, 10, 12, or 24 Vdc excitation output is standard to power transducers or two-wire transmitters. Ratiometric operation, which automatically compensates for changes in the applied excitation, is jumper selectable for applications, such as bridges, where the signal to be measured is proportional to the excitation level.

Display
Readout 6 LED digits, 7-segment, 14.2 mm (.56"), red or green
Display Range -999,999 to +999,999, XXXXEX scientific notation beyond 999,999
Zero Adjust -999,999 to +999,999
Span Adjust 0 to ±999,999
Indicators Four LED lamps
Pulse Inputs (FR signal conditioner)
Signal Types AC, pulses from NPN, PNP transistors, contact closures,magnetic pickups.
Ch A Frequency, Max 1 MHz
Ch B Frequency, Max 250 kHz
Signal Ground Common ground for channels A & B
Minimum Signal Nine ranges from (-12 to +12 mV) to (+1.25 to +2.1V)
Maximum Signal 250 Vac
Maximum Frequency 1 MHz, 30 kHz, 250 Hz (selectable)
Conversion Technique Inverse period
Delay between batches Selectable 10 ms to 199.99 s
Recalibration: All ranges are calibrated at the factory. Recalibration is recommended every 12 months.
Power Supply Boards (one required)
Voltage, standard 85-264 Vac or 90-300 Vdc
Voltage, optional 12-32 Vac or 10-48 Vdc
Frequency DC or 47-63 Hz
Power consumption 1.2W @ 120 Vac, 1.5W @ 240 Vac, 1.3W @ 10 Vdc, 1.4W @ 20 Vdc,
   (typical, base meter) 1.55W @ 30 Vdc, 1.8W @ 40 Vdc, 2.15W @ 48 Vdc
Power Isolation 250V rms working, 2.3 kV rms per 1 min test
Excitation Output (standard)
5 Vdc 5 Vdc ± 5%, 100 mA (jumper selectable)
10 Vdc 10 Vdc ± 5%, 120 mA (jumper selectable)
12 Vdc 12 Vdc ± 5%, 100 mA (jumper selectable)
24 Vdc 24 Vdc ± 5%, 50 mA (jumper selectable)
Output Isolation 50 Vdc from signal ground
Analog Output Boards (one optional)
Output Levels 4-20 mA, 0-20 mA, 0-10V, -10 to +10V (single-output option)
Current compliance 4-20 mA, 0-20 mA, 0-10V (dual-output option)
Voltage compliance 2 mA at 10V ( > 5 kΩ load)
Scaling 12V at 20 mA ( < 600 Ω load)
Resolution Zero and full scale adjustable from -99999 to +99999 16 bits (0.0015% of full scale)
Isolation 250V rms working, 2.3 kV rms per 1 min test (dual analog outputs share the same ground)
Relay Output Boards (one required for batch control)
Dual magnetic relays 2 Form C, 10A max, 440Vac or 125Vdc max, 2500VA or 300W
Quad magnetic relays 4 Form A (NO), 10A max, 440Vac or 125Vdc max, 2500VA or 300W
Dual solid state relays 2 Form A (NO), AC or DC, 0V - 400V, 120Ma, 35Ohms (max at On-State)
Quad solid state relays 4 Form A (NO), AC or DC, 0V - 400V, 120Ma, 35Ohms (max at On-State)
Relay commons Isolated commons for dual relays or each pair of quad relays
Relay isolation 250V rms working, 2.3 kV rms per 1 minute test
Relay latching modes Latching or non-latching
Relay active modes Active on or off, active high or low
Hysteresis modes QA passband mode, split hysteresis, span hysteresis
Communication Boards (one optional)
Board Selections RS232RS485 with dual RJ11 connectors, RS485 with dual RJ45 connectors, USB, High-Speed Ethernet, USB-to-RS485 gatewayHigh-Speed Ethernet-to-RS485 gateway, WiFi with built-in antenna plus USB & RS485, WiFi with external antenna plus USB & RS485
Protocols Laurel Custom ASCII (serial), Modbus RTU (serial), Modbus TCP (Ethernet or WiFi)
Digital Addresses 247 (Modbus), 31 (Laurel ASCII),
Isolation 250V rms working, 2.3 kV rms per 1 min test
Environmental
Operating Temperature -40°C to 70°C (-40°F to 158°F)
Storage Temperature -40°C to 85°C (-40°F to 185°F)
Relative Humidity 95% at 40°C, non-condensing
Protection NEMA-4X (IP-65) when panel mounted
Signal Connections
Signal connections to Laurel pulse input batch controller
Mechanical
Enclosure 1/8 DIN, high impact plastic, UL 94V-0, color: black
Mounting 1/8 DIN panel cutout required: 3.622" x 1.772" (92 mm x 45 mm).
Dimensions 4.68" x 2.45" x 5.64" (119 mm x 62 mm x 143 mm) (W x H x D)
Maximum panel thickness 4.5 mm (0.18")
Tightening Torque - Connectors Screw terminal connectors: 5 lb-in (0.56 Nm)
Tightening Torque - Pawls Digital Panel Meter Case Pawls: 5 lb-in (0.56 Nm)
Weight of base meter 210 g (7.4 oz) typical (DPM, counter, timer, 6-digit remote display)
Weight of option boards 30 g (1.0 oz) typical per board (analog output, relay output, communications)
General
Programming Methods Four front panel buttons or via Laurel's free Instrument Setup Software, which runs on a PC under MS Windows. 
Security Lockout options include using the front panel buttons, the free Instrument Setup Software, or a hardware jumper.
Warranty 3 years parts & labor
Recalibration: All ranges are calibrated at the factory. Recalibration is recommended every 12 months.

Free Instrument Setup Software for Series 2 Laureates

Digital Panel Meter Laurel Electronics Digital Transmitters
1/8 DIN Digital Panel Meters DIN Rail Transmitters

Free Downloadable Windows-based Instrument Setup (IS) software (Data Interface Board Required) for use with our programmable Digital Panel Meters, Scale Meters, Counters, Timers, Remote Displays, and Transmitters, are an easy method to set up Laureate 1/8 DIN digital panel meters, counters, timers, remote displays, and DIN-rail transmitters, as explained in the Instrument Setup Software Manual. Laureate 1/8 DIN instruments can also be set up from the front panel, as explained in their respective Owners Manuals. Instrument Setup software is of benefit whether or not the PC is connected to the instrument.

  • When the PC is connected to the instrument, Instrument Setup software can retrieve the setup file from the instrument or open a default setup file or previously saved setup file from disk View Setup, then provides graphical user interface (GUI) screens with pull-down menus applicable to input, display, scaling, filtering, alarms, communications, analog output, and front panel lockouts. Fields that are not applicable to the instrument as configured are either left out or grayed out. Clicking on any item will bring up a detailed Help screen for that item. After editing, the setup file can be downloaded, uploaded to the instrument, or saved to a disk. The same setup file can then be downloaded into multiple instruments.
  • When the PC is not connected to the instrument, the above GUI screens can be used to set up a virtual instrument. The setup file can then be saved to disk. Switching toView Menu then brings up a screen with the required front panel programming steps. This view can be printed out for use at the instrument site and to serve as a hard copy record.

    Download Free Instrument Setup Software


Installation

Set User Account Control (UAC) of MS Windows to "Never notifiy me" so that Instrument Setup Software can create directories. The UAC change screen can be reached as follows:

  • Under Windows 7, click on the Windows Start button in the lower left of the desktop and enter "UAC" in the search field.
  • Under Windows 8, navigate to Control Panel, then to the "User Accounts and Family Safety" section, and click on "Change User Account Control Settings."
  • Under Windows 10, click on the Windows Start button in the lower left of the desktop, then on "Settings", and enter "UAC" in the search field.
  • Reboot your computer for the changed UAC setting to take effect.
Meter board with USB Type-B connector

RJ11-to-DB9 cable with rear view of DB9 connector to PC

Laurel USB cable, P/N CBL05

RS232 cable, meter to PC, P/N CBL01

Laureate 1/8 DIN Laureate instruments must be equipped with a serial communications board and be connected to the computer via a serial communications cable. The connection can be via RS232, RS485, USB or Ethernet. Following setup, the serial communications board may be removed from the instrument if desired. The wiring of the RS232 cable is illustrated above with end views of the two connectors.

Laureate LT Series transmitters come standard with a 3-wire serial interface, which can be jumpered for RS232 or RS485.
Laureate LTE Series transmitters come standard with an Ethernet interface.

Meter Setup Screens

Click on any of the reduced screens below for a full-size screen view, then click on the Back button of your browser to return to this page. The screens examples below are for a fully-loaded Series 2 Digital Panel Meter (DPM), which is connected to the PC via RS232. If the meter is a Series 1 meter (pre-2007), this is sensed by the software, and somewhat different screens are brought up. Please see Series 1 setup screens.

Laurel Dual Channel Pulse Input Rate Meter
Welcome Screen
From the computer desktop, click on Start > Programs > IS2 > IS2. Or click on the IS icon on your desktop. This splash screen will be displayed for three seconds. The software revision number is in the lower right.
more
Setup Screen 02s for Digital Panel Meters and Digital Transmitters
Communications Selection Screen
Specify your desired communication protocol and the serial communications bus type, which should match the jumper setup of the instrument. Select None if the PC is not connected to the instrument.
more
Setup Screen 3 for Digital Panel Meters and Digital Transmitters
Establish Communications Screen
If you selected RS-232, you will be asked to specify the PC Com Port and Baud Rate, which should match the jumper setup of the instrument. Click on Establish. With the right settings, the Communications Established field will light up in green, and the Meter Type will be recognized. If so, click onMain Menu.
more
Setup Screen 4 for Digital Panel Meters and Digital Transmitters
Main Menu Screen
Click on File > Default Setup to retrieve the default setup file from disk for your type of meter. Click on File > Open Setupto retrieve a previously saved setup file from disk or on File > Save Setup to save your edited setup file to disk. Click onDPM > Get Setup to retrieve the setup file from your meter or on DPM > Put Setup to download your edited setup file into the meter.
more
Setup Screen 5 for Digital Panel Meters and Digital Transmitters
DPM Input + Display Setup Screen
From the Main Menu, click on View > Setup, then on theInput+Display tab. You can now specify the meter hardware, signal type, display mode, and functions of control inputs A and B. Clicking on any item brings up a pull-down menu with the available choices.
more
Setup Screen 6 for Digital Panel Meters and Digital Transmitters
DPM Scaling Setup Screen
Click on the Scaling tab, which provides three scaling methods to relate the signal to the displayed reading: 1) Scale and Offset method, 2) Coordinates of two points method, and 3) Reading Coordinates of Two Points method. The last method uses actual high and low signals, and the computer will prompt you.
more
Setup Screen 7 for Digital Panel Meters and Digital Transmitters
DPM Filter Setup Screen
Click on the Filter tab, which allows you to specify the digital filter time constant (if any), the adaptive filter threshold, and whether Peak / Valley values are filtered or unfiltered. As for all setup screens, clicking on the F1 key while an item is highlighted brings up a Help screen for that item, as illustrated.
more
Setup Screen 8 for Digital Panel Meters and Digital Transmitters
DPM Relay Alarms Setup Screen
Click on the Relay Alarms tab, which allows you to set up Alarms 1 and 2 for the optional dual relay output board. Clicking on any of the four numeric fields changes these to green and brings up a special field to enter the desired numeric value, which is tied to the displayed reading.
more
Setup Screen 9 for Digital Panel Meters and Digital Transmitters
DPM Communications Setup Screen
Click on the Communications tab so set up serial communications. In particular, you can special the Serial Protocol and the meter address if multiple meters are to be addressed on the same serial data line.
more
Setup Screen 10 for Digital Panel Meters and Digital Transmitters
DPM Analog Output Setup Screen
Click on the Analog Out tab so set up the optional analog output board. Three output ranges are selectable, the endpoints of which can be tied to user-specified High and Low readings.
more
Setup Screen 11 for Digital Panel Meters and Digital Transmitters
DPM Lockouts Setup Screen
Click on the Lockouts tab to check off menu items which will no longer be accessible from the front panel of the meter. This will simplify meter operation and prevent unintended setup changes.
more

Meter Setup Utilities

Setup Screen 12 for Digital Panel Meters and Digital Transmitters
DPM Front Panel Setup Screen
As an aid to programming the meter from the front panel when a serial connection is not available, you can return to the Main Menu and click on View > Menu. The required sequence of front panel screens will then be displayed. Click on any step in the sequence for the meaning of each digit, as illustrated for the FILtEr step. For a hardcopy, simply press on Print.
more
Setup Screen 13 for Digital Panel Meters and Digital Transmitters
DPM Jumper Setup Screen
Specify your desired communication protocol and the serial communications bus type, which should match the jumper setup of the instrument. Select None if the PC is not connected to the instrument.
more
Setup Screen 14 for Digital Panel Meters and Digital Transmitters
DPM Jumper Setup Screens
Click on any of the displayed plug-in boards, and you will be presented with the jumper positions and electrical connections for your selected board. This minimizes the need to refer to the printed manual.
more
Setup Screen 15 for Digital Panel Meters and Digital Transmitters
DPM Commands Screen
This page allows you set up external input, serial communications, an analog output proportional to the display (optional), and lockouts for Laureate digital counters. The grayed out area at the top right of the screen applies to Laureate remote displays.
more
Graphical Output Screens (not available with Ethernet)

From the Main Menu, click on Readings if your PC is connected to the meter. A pull-down menu then offers three choices: ListPlot and Graph.

  • List presents the latest readings in a 20-row by 10-column table. Press Pause at any time to freeze the display. This is one method to capture peak readings.   
  • Plot generates a plot of readings vs. time in seconds. It effectively turns the DPM-PC combination into a printing digital oscilloscope.
    more 
  • Graph generates a histogram where the horizontal axis is the reading and the vertical axis is the number of occurrences of readings. The display continually resizes itself as the number of readings increases.
    more
Setup Screen 18 for Digital Panel Meters and Digital Transmitters
DPM Calibration Screens
Click on the Scaling tab, which provides three scalClick on the Scaling tab, which provides three scaling methods to relate the signal to the displayed reading: 1) Scale and Offset method, 2) Coordinates of two points method, and 3) Reading Coordinates of Two Points method. The last method uses actual high and low signals, and the computer will prompt you.
more
Setup Screen 19 for Digital Panel Meters and Digital Transmitters
Frequency Meter Calibration Screen
Calibration of the quartz crystal of the Laureate frequency meter requires the input of a known frequency from a calibrator. Apply the frequency, then enter the frequency in Hertz. Calibration will be automatic, with storage of the calibration factor stored in non-volatile memory.
more

 

Laureate™ 1/8 DIN Case For Laureate Digital Panel Meters, Counters, Timers & Remote Displays

Laurel panel meter case

Key Features

  • Meets 1/8 DIN Standard.
  • Installs from front of panel.
  • Short depth behind the panel: only 4" (102 mm) plus connectors.
  • Understated 0.157" (4 mm) thick bezel.
  • Meets NEMA 4X (IP-65) for high-pressure wawshdon when panel mounted.
  • Screw clamps connectors meet VDE / IEC / UL / CSA safety standards.
  • Rugged GE Lexan® housing material.
  • Safety certified per EN 61010-1.
CE CertifiedRoHs CertifiedETL Certified

Dimensions

Mechanical specifications of Laureate digital panel meters and electronic counters

Maximum panel thickness: 4.5 mm (0.18")
Weight of base meter:
210 g (7.4 oz) typical (DPM, counter, timer, 6-digit remote display)
Weight of option boards: 30 g (1.0 oz) typical per board (analog output, relay output, communications)
Tightening Torque - Connectors: Screw terminal connectors: 5 lb-in (0.56 Nm)
Tightening Torque - Pawls: Digital Panel Meter Case Pawls: 5 lb-in (0.56 Nm)
Dimensioned CAD assembly drawings in EPRT, STEP, x_t. dwg, pdf file formats: Laureate-meter-case.zip (zipping prevents browser from opening CAD files as text files).

Panel Mounting

Mechanical Panel Mounting GuideSlide the meter into a 45 x 92 mm 1/8 DIN panel cutout. Ensure that the provided gasket is in place between the front of the panel and the back of the meter bezel. The meter is secured by two pawls, each held by a screw, as illustrated. Turning each screw counterclockwise extends the pawl outward from the case and behind the panel. Turning each screw clockwise further tightens it against the panel to secure the meter.

Turning each screw counterclockwise loosens the pawl and retracts it into its well. This position allows installed meter to be removed from their panel, or new meters to be installed in a panel. Do not remove the screws from their pawls. Doing so would cause the screw and pawl to fall off and likely get lost. Do not overtighten so as not to damage the plastic parts.

 

Drum Filling Application Utilizing Two Relay Outputs
Drum filling batch controller application utilizing two relay outputs In this drum filling application, the Laureate pulse-input batch controller utilizes uses its two relays to control a pump. The Prewarn relay slows down the pump near the preset to avoid overshoot. The Batch relay stops the pump at the preset.
Controlling Chemical Mixing of Materials
Controlling mixing of materials using two Laureate batch controllers Multiple Laureate batch controllers can be used in combination to control the mixing of materials in the proper ratio. Each feed line is equipped with its own pump, flowmeter, and Laureate. Controller setup and monitoring of the mixing operation are facilitated by optional serial communications. RS485 allows a single data line to handle multiple controllers.
Up-Counting Batch Control
Up-counting batch controller using the Laureate Batch Controller In up-counting batch control, the Laureate counts up from zero to a preset maximum. A prewarn level is available to slow down filling near the preset to avoid overshoot. A time delay can be programmed from the end of each batch to the start of the next batch.
Down-Counting Batch Control
Down-counting batch control using the Laureate Batch Controller In down-counting batch control, the Laureate counts down from the preset maximum to zero. A prewarn level is available to slow down filling or emptying near zero. Again, a time delay can be programmed from the end of each batch to the start of the next batch.
Discrete Filling and Batch Counting
Discrete filling and batch counting using the Laureate Batch Controller The Laureate batch controller is ideal for discrete manufacturing as well as repetitive fill operations. In this example, the Laureate counts bottles which it then groups into sixpacks. Its Grand Total capability can be used to track bottles or sixpacks.

 

Batch Controller Digital Panel Meter Frequently Asked Technical Questions

They are the same, but “Batch Control” is a user selectable operating mode of the Extended Laureate counter with the FR dual-channel pulse input signal conditioner board. The higher cost “Extended” versions of the Laureate counter (model numbers beginning with L7 or L8) offer programmable capabilities not offered by the Basic versions (model numbers beginning with L5 or L6). “Batch Control” enables specific features for repetitive fill operations. A relay board with 2 or 4 relays is also required in the counter to turn pumps and valves on or off.
The same signal from a pulse output flow sensor is applied in parallel to Channels A and B. Three values are tracked and can be separately displayed by pressing the RESET key: Item #1, the Batch Total; Item #2, the Grand Total of all batches or Number of Batches (selectable during setup); and Item #3, the Fill Rate. Using the dual relay board, relay #1 is used as the batch relay to control the main fill operation. Relay #2 can be assigned to another limit, such as pre-warn to slow filling near the setpoint, end-of-process, or rate alarm. The next fill operation can be programmed to be start after a specified gate time or upon receipt of an external contact closure input.
The displayed values for total or rate can be scaled to engineering units with a user selectable number of digits after the decimal point, such as 45.97 gallons, 0.267 gallons/min or 8.24 liters/sec. Scaling is normally done from the counter’s front panel but can also be done with Instrument Setup (IS) software if the counter is equipped with a communications board. With batch control, scaling normally converts pulse counts to units of volume, such as gallons, liters or cubic feet. Scaling normally converts input frequency in Hz flow rate in units of volume per second or minute.
When equipped with the FR dual channel pulse input signal conditioner board (P/N LSCDF), the Batch Controller accepts output pulses from a turbine flow meter. These can be voltage pulses from an active sensor or a magnetic pickup. The FR signal conditioner board can also be jumpered for contact closure inputs, signals from proximity switches with a PNP or NPN output, or high-level signals up to 250 Vac. When equipped with the VF voltage-to-frequency signal conditioner board (P/N LSCAF), the Batch Controller accepts 4-20 mA, 0-1 mA or 0-10V analog signals, as selected by jumpers.
The firmware of the Basic counter needs to be converted to an Extended counter. This can only be done at the factory. However, option boards like dual or quad relay boards, can be purchased separately be simply plugged in later. The presence of a new board and the type of board are automatically sensed by the meter’s firmware or by  Instrument Setup (IS) software. If you change boards, also change the model number on the meter label.
The Batch Controller is but one user-programmable function of the Laurel’s Extended counter. Other functions are independent rate or total one channels A and B, rate on A and total on B, arithmetic combinations of channels A and B, stopwatch, averaging timer, phase angle, duty cycle, and more, as described in the Laureate counter user manual.
The only thing which can be calibrated in a Laureate counter is the quartz crystal time base which is used for frequency or rate. Note that calibration is different from scaling. Calibration is used to bring readings in harmony with national standards, like those of the USA’s National Institute of Standards and Technology (NIST). Factory calibration sets the quartz crystal time base to an accuracy of 2 ppm (parts per million) but will change by a few ppm over time. It may never need to be redone for most industrial applications. Calibration is done at the factory by using a precision 100 kHz quartz crystal calibrator. Calibration can also be done in the field by applying a precision 100 kHz square wave signal from any precision frequency source, as explained in the 1-page "Counter Calibration" section of the user manual .

 

 

CAL-Digital

Certificate of Calibration

$65.00

DLS-XLOG2

XLog2 Data logging Software

$495.00

IPC

Splashproof Cover

$55.00

CON01

CON01 Connector

$75.00

CBL01

RS232 Cable for Meters

$35.00

CBL02

USB-to-RS232 Adapter Cable

$47.00

CBL04

RS232 Cable for LT Transmitters

$47.00

CBL05

USB Data Cable for Meters

$47.00

CBL06

USB-to-RS485 Adapter Cable

$47.00

CBL07

USB Programming & Data Cable

$47.00

CBL08

RS485 Splitter Cable

$33.00

CBL6

6-foot Power Cable

$41.00

CBL12

12-foot Power Cable

$47.00

Modular Design for Maximum Flexibility at Minimum Cost

All boards are isolated from meter and power grounds. Optional Plug-in-Play boards for communications and control include Ethernet, WiFi, serial communication boardsdual or quad relay boards, and an analog output board. Laureates may be powered from 85-264 Vac or optionally from 12-32 Vac or 10-48 Vdc. The display is available with bright red or green 0.56" (14.2mm) high LED digits. The 1/8 DIN case meets NEMA 4X (IP65) specifications from the front when panel mounted. Any setup functions and front panel keys can be locked out for simplified usage and security. A built-in 5, 10, 12, or 24 Vdc excitation supply can power transducers, eliminating the need for an external power supply. All power and signal connections are via UL / VDE / CSA rated screw clamp plugs.

The Laureate™ Series features modular design with up to 7 isolated plug-in boards, applicable to all Laureate 1/8 DIN Digital Panel Meter.

Schematic for Digital Panel Meter

Modular Hardware

The design of the Laureate™ Series is modular for maximum flexibility at minimum cost. All boards are isolated from meter and power grounds. The base configuration for a digital panel meter or counter consists of a main module (with computer and plug-in display boards), a power supply board, and a signal conditioner board. Optional plug-in-play boards include an isolated setpoint controller board, an isolated analog output board, and an isolated digital interface board. Modular design and a choice of plug-in options allow the Laureate to be customized for a broad range of applications from simple monitoring to control and computer interface. There can be up to five plug-in boards in a 1/8 DIN Laureate.

Dual Board sets

Connecting Laureate Digital Panel Meter to a Local Area Network (LAN)

Up to 30 Laureate Digital Panel Meter and/or LT Transmitters can be configured for RS485 and daisy-chained to an LT Transmitter using Laurel’s High Speed Ethernet-to-RS485 converter board for seamless LAN integration. Alternatively, Laurel LTE series Ethernet transmitters can connect directly to a LAN via an Ethernet cable. Setup for both configurations is streamlined using Laurel’s free Instrument Setup Software, which simplifies node discovery and transmitter configuration.

Flexible Communication Options for Digital Panel Meter

The Laureate Digital Panel Meter can be equipped with Laurel communication boards to support various interfaces and protocols. These include serial interfaces with ASCII or Modbus RTU protocols, and Ethernet interfaces with web access, ASCII, or Modbus TCP/IP protocols, ensuring versatile connectivity for your commercial applications.

Laurel network with Ethernet-to-analog converter board

Ordering Guide
Part Number as Configured: L81106FR
Price as Configured: $642.00

Click on the Option Board Links for More Product Information

Base Item
$169.00
Display Color
$41.00
$41.00
Power (Isolated) $75.00
$115.00
Relay Output (Isolated)
$0.00
$101.00
$70.00
$128.00
$96.00
Analog Output (Isolated)
$0.00
$115.00
$172.00
Data Interface (Isolated)
$0.00
$81.00
$109.00
$135.00
$81.00
$135.00
$237.00
$259.00
$182.00
$204.00
$171.00
$193.00
$204.00
$226.00
Signal Input (Isolated)
$81.00
Part Number as Configured:
L81106FR
Price as Configured:
$642.00
Quantity:
- +
Extended Price:
$642.00

Understanding the Laureate™ Digital Panel Meter Batch Controller, Pulse Input

The Laureate™ 1/8 DIN Digital Panel Meter batch controller is a low-cost, highly accurate controller for repetitive fill operations, using the FR dual-channel pulse input signal conditioner for turbine flow meters. Relay control is provided by two or four 8A contact relays, or two or four 120 mA AC/DC solid state relays. Fill operations repeat continually with a programmable delay from 10 ms to 199.99 sec, or based on an external control input.

Three Tracked Items

Item #1 is the current batch total, set up to count up from zero to a preset limit, or down from a preset limit to zero. Item #2 can be assigned to grand total or number of batches. Item #3 is the flow rate. Each can be scaled to engineering units and displayed on the six-digit LED display.

Channel Roles

The same signal is applied in parallel to Channels A and B, used independently. Channel A is used for totalizing, mathematically scaled for control and display of volume in engineering units. Channel B is used for rate, determined by timing an integral number of periods over a specified gate time (plus 30 ms and 0-2 periods) and taking the inverse of period — allowing much greater accuracy and faster update times than conventional rate meters that count pulses over a fixed interval, with update times as high as 25/second.

Relay Assignment Flexibility

Relay #1 is assigned to batch total to control the filling operation. Relays #2, #3, and #4 can each be assigned by the user to Items #1, #2, or #3. For example, Relay #2 can be assigned to Item #1 with a lower setpoint to serve as a pre-warn and slow the fill rate near the batch setpoint, and Relay #3 can be assigned to the total number of batches to terminate batching once a preset number of containers has been filled.

Communications and Remote Displays

An optional serial communications board transmits Items #1, #2, and #3, plus peak for Item #3 (rate). If all four values are needed simultaneously, the batch controller can be augmented with up to three Laureate remote displays, each with its own analog output and relays for alarm or control.

Real-World Applications

  • Drum Filling With Two Relay Outputs — the Prewarn relay slows the pump near the preset to avoid overshoot; the Batch relay stops the pump at the preset.
  • Controlling Chemical Mixing of Materials — multiple Laureate batch controllers combine to control mixing in proper ratio, each feed line with its own pump, flowmeter, and controller; RS485 allows a single data line to handle multiple controllers for setup and monitoring.
  • Up-Counting Batch Control — counts up from zero to a preset maximum, with a prewarn level available to slow filling near the preset.
  • Down-Counting Batch Control — counts down from a preset maximum to zero, with a prewarn level available to slow filling or emptying near zero.
  • Discrete Filling and Batch Counting — ideal for discrete manufacturing as well as repetitive fill operations, such as counting bottles grouped into six-packs, with Grand Total tracking either bottles or six-packs.

Factory-Calibrated Accuracy

All signal conditioner board ranges are factory-calibrated, with calibration factors stored in EEPROM. Field replacement of the signal conditioner board doesn't require recalibrating the meter. Factory recalibration is recommended annually.

Where Pulse-Input Batch Controller Digital Panel Meters Are Used

  • Drum & Tote Filling — turbine flow meter driven pump control with prewarn slow-down.
  • Multi-Ingredient Chemical Blending — networked controllers maintaining precise mixing ratios.
  • Bottling & Container Filling Lines — up or down counting with grand total tracking of batches.
  • Fuel & Lubricant Dispensing — repetitive, precisely controlled fill cycles.
  • Discrete Parts Grouping — counting individual units into packaged groups.
  • Water & Wastewater Chemical Dosing — repetitive, metered chemical batch additions.
  • Multi-Zone Remote Monitoring — batch total, grand total, and rate distributed to remote displays.

Batch Controller Digital Panel Meter Frequently Asked Questions

Why does the batch controller apply the same physical signal to both Channel A and Channel B rather than using two separate sensors?

Documented setup specifically applies the same turbine flow meter signal in parallel to both channels — since totalizing and rate calculation are computed differently internally (accumulated count versus inverse-period timing), running both calculations from the same underlying pulse stream lets one flow sensor simultaneously support both the batch total and the live fill rate, without needing a second sensor.

Can Item #2 track grand total and number of batches simultaneously, or is it one or the other?

Documented capability specifically describes Item #2 as selectable during setup to be either grand total or number of batches — meaning it's one assignment at a time rather than tracking both simultaneously; an application needing both values would need to use Item #2 for one and find another way (such as calculating batches from grand total divided by typical batch size) for the other.

Does assigning Relay #2 to a pre-warn function on Item #1 require it to use the same preset value as Relay #1's batch-complete setpoint?

No — the documented pre-warn example specifically uses a lower setpoint than the main batch relay's target, intentionally triggering earlier so the fill can slow down before reaching the final batch total; Relay #2's setpoint on Item #1 is independently configurable from Relay #1's batch-complete setpoint.

If a fourth relay is available, does it have to be assigned to a genuinely different item than the other three relays?

Documented flexibility specifically states relays #2, #3, and #4 can each be assigned by the user to Items #1, #2, or #3 — there's no documented requirement that each relay track a different item; a fourth relay could, for example, provide a second alarm threshold on the same item Relay #2 already monitors, if that's what an application needs.

Does the peak value transmitted for Item #3 represent the peak rate during the current batch, or an all-time peak?

Documented capability specifically states the optional serial communications board can transmit peak for Item #3 (rate) alongside Items #1, #2, and #3 themselves — the specific peak-tracking window (per-batch versus cumulative) isn't detailed on this page, so confirming that behavior against the counter's documented peak/valley capture settings is worth doing if the distinction matters for a given application.

Can up-counting and down-counting batch control both use the same prewarn relay concept, or is prewarn only available for one counting direction?

Both documented modes specifically include a prewarn capability — up-counting batch control documents a prewarn level to slow filling near the preset maximum, while down-counting batch control documents an equivalent prewarn level to slow filling or emptying near zero; the underlying concept works symmetrically for either counting direction.

In the discrete filling and batch counting example, does the Grand Total need to be reconfigured to switch between tracking bottles and tracking six-packs?

Yes, in effect — Grand Total is documented as being usable to track either bottles or six-packs in that specific example, which implies it's configured for one or the other based on which item and scaling the application assigns to it; switching what physical quantity it represents would mean reconfiguring which count (individual bottles versus grouped six-packs) feeds that specific tracked total.

Does the delay-between-batches setting and the external-control-input start option work together, or are they mutually exclusive ways to trigger the next fill?

Documented capability describes fill operations as repeating continually with a programmable delay, or based on an external control input — this is presented as a choice between two triggering methods for starting the next batch cycle, rather than both operating simultaneously; an application would configure the meter for one triggering method or the other depending on whether batches should proceed automatically on a timer or wait for an external signal.

Does Channel A's totalizing function stop updating while Channel B is busy calculating rate, or do both run continuously and independently?

Documented architecture specifically describes Channels A and B as used independently even though they share the same input signal — Channel A's totalizing and Channel B's inverse-period rate calculation are separate, parallel processes rather than a shared computation the meter alternates between, so both the running batch total and the live rate continue updating simultaneously.

Can the delay between batches be set differently for different batch sizes, or is it a single fixed setting for all cycles run on that meter?

The documented delay-between-batches setting (10 ms to 199.99 s) is a single configured value applied between cycles — it's not documented as varying automatically based on the batch size just completed, so an application needing different pause durations for different product runs would need to reconfigure that setting when switching between batch types, rather than expecting the meter to adjust it automatically.

Turbine Flow Meter K-Factor & Calibration Questions From the Field

What exactly is a turbine flow meter's K-factor, and how is it actually determined?

Documented explanation specifically defines K-factor as the number of pulses generated per unit of volume passing through the meter — determined by passing a known quantity of fluid through the meter at a given flow rate, counting the total pulses generated, and dividing pulses by that known volume, producing a calibration constant unique to that individual meter.

Is a turbine flow meter's K-factor genuinely constant across its entire rated flow range?

Not entirely — documented analysis specifically describes the meter's response as having a linear section (roughly two-thirds of its working range, with characteristics tied to sensor geometry and fluid viscosity) and a nonlinear section, where bearing friction and fluid viscous resistance have a greater effect — for the highest-accuracy or custody-transfer applications, documented practice specifically applies a multi-point linearization curve with several K-factors across the range rather than a single constant value.

Does entering the wrong K-factor into a batch controller cause a random, unpredictable error, or a specific, calculable one?

A specific, calculable error — since K-factor is a direct multiplier converting raw pulse count into volume, a K-factor mismatch produces a proportional, systematic under- or over-reporting of every batch total, documented as directly affecting dosing accuracy, inventory management, and regulatory compliance rather than introducing random noise.

Can a turbine meter's K-factor genuinely drift or change over the life of the installed meter?

Yes — documented field examples specifically describe a real fuel distribution terminal that discovered an average 1.5% discrepancy between delivered and billed volumes on high-precision turbine meters after 18 months of continuous operation, illustrating that K-factor stability isn't guaranteed indefinitely and periodic verification remains genuinely important even for well-regarded meter technology.

What documented installation or maintenance practices specifically help preserve a turbine meter's K-factor accuracy over time?

Documented best practices specifically include using clean, filtered, or strainer-conditioned flow to prevent rotor fouling and bearing damage, maintaining the manufacturer's recommended straight-run pipe lengths upstream and downstream to avoid a distorted flow profile, and re-verifying calibration specifically after any cleaning, repair, or exposure to abnormal operating conditions before returning the meter to service.

Does the turndown ratio of a turbine flow meter affect how reliable its K-factor is at low flow rates within that meter's rated range?

Yes — documented specification cites turbine meters as inherently linear within a known turndown range, commonly around 15:1, based on fluid velocity through the meter; operating meaningfully outside that documented turndown range pushes the meter into its nonlinear response region, where the single-point K-factor becomes progressively less representative of actual flow.

Is it accurate to assume two turbine meters of the identical model and size share the exact same K-factor?

No — documented guidance specifically notes that while batch-produced meters of the same design are likely to have very similar K-factors, each individual meter's K-factor is unique to that specific device as measured on its own calibration certificate — using a generic, nameplate-style K-factor rather than the individually calibrated value for that specific meter introduces avoidable error.

Does distinguishing between "of full scale" (FSD) accuracy and "of reading" accuracy actually matter when comparing flow meters for a batch controller application?

Yes — documented industry commentary specifically flags this distinction as one suppliers don't always clarify, and notes that linearity-related reading accuracy has a particularly significant impact on flow meter performance at the low end of its flow range; understanding which accuracy convention a given meter's spec sheet is actually quoting matters specifically for applications with a wide operating flow range or frequent low-flow batches.