Panel Meter for Batch Controller Analog Input Applications P/N L8112DVF2

Panel Meter for Batch Controller Analog Input Applications

Price: $872.00
  • P/NL8112DVF2
- +

Features

  • Provides automatic control for repetitive liquid fill operations
  • Available for turbine flow meter pulse signals from 0 Hz to 1 MHz or analog flow meter signals (4-20 mA, 0-1 mA or 0-10V)
  • 6-digit scalable display to ±999,999 for batch total, grand total, number of batches, or flow rate
  • Counts up from 0 to preset or down from preset to 0
  • Two or four control relays for with settable delay between cycles
  • All input ranges are user selectable and factory calibrated
  • Digital span adjustment: 0 to ±999,999; zero adjustment: -999,999 to +999,999
  • Front panel scalable: 0 to ±999,999 for use with current shunts
  • 1/8 DIN size with bright red or green 0.56" (14.2mm), high LED digits
  • Transducer excitation output, 5, 10, 12, or 24 Vdc (isolated)
  • Power 85-264 Vac / 90-300 Vdc or 10-48 Vdc / 12-32 Vac (isolated)
  • Operating temperature from -40°C to 70°C  (-40°F to 158°F)
  • Wide choice of Plug-in-Play options:
    - 2 or 4 relays, mechanical or solid state, for alarm or control (isolated)
    - 1 or 2 Analog output, 4-20 mA, 0-20 mA, 0-10V, or -10V to +10V (isolated)
    - Communications: Ethernet, WiFi, USB, RS232, RS485 (isolated)

The Laureate™ 1/8 DIN Panel Meter batch controller

is a low cost, powerful and highly accurate batching controller for repetitive fill operations. It can use the Laureate V-to-F analog signal conditioner for use with 4-20 mA, 0-1 mA or 0-10V conditioned flow meter signals. Relay control can be provided by two or four 8A contact relays, or by two or four 120 mA AC/DC solid state relays. Fill operations are repeated continually with a programmable delay from 10 ms to 199.99 sec, or based on an external control input.

Three items are tracked by the batch control software. These can each be scaled to engineering units of total or flow rate and displayed by the controller's six-digit LED display: Item #1 is the current batch total, which can be set up to count up from zero to a preset limit, or down from a preset limit to zero. Item #2 can be assigned to grand total or number of batches. Item #3 is the flow rate.

The Laureate Panel Meter is easily programmed with Laurel’s free Instrument Setup Software, downloadable from our website and compatible with Windows PCs, requiring a data interface board for setup.

All signal conditioner board ranges are factory-calibrated, with calibration factors for each range securely stored in an onboard EEPROM. These factors can be scaled via software to accommodate external shunts, enabling field replacement of signal conditioner boards without necessitating recalibration of the associated panel meter. For optimal accuracy, factory recalibration is recommended annually. All Laurel Electronics instruments undergo factory calibration using the industry-leading Fluke calibrators, which are recalibrated yearly and certified traceable to national standards, ensuring the highest level of precision and reliability.

Two or four relays can be used. Relay #1 is assigned to batch total to control the filling operation. Relays #2, #3 and #4 can each be assigned by the user to Items #1, #2 or #3. For example, Relay #2 can be assigned to Item #1 (batch total) with a lower setpoint to serve as a pre-warn and slow down the fill rate near the batch setpoint, and Relay #3 can be assigned to the total number of batches to terminate the batching when a present number of bottles have been filled.

An optional serial communications board allows the batch controller to transmit Items #1, #2 and #3, as well as peak for item #3 (rate). If required, all four items can be displayed simultaneously by augmenting the batch controller with up to three Laureate remote displays. Each of these can have its own analog output and relays for alarm or control.

Batch Control with Conditioned Flow Signals

The analog input batch controller utilizes the Laureate VF voltage-to-frequency converter signal conditioner board, which converts 4-20 mA, 0-1 mA or 0-1V conditioned flow meter signals to a frequency from 10 kHz to 110 kHz. This allows the counter controller to totalize flow, to count up to a preset value, or to count down to zero from a preset value for batch control. One of the relays is dedicated to On/Off batch control, while the other relay is available to slow down rate near the setpoint or to provide another alarm or control function based on rate or total.

Digital signal filtering modes can be selected to ensure stable readings in electrically noisy environments.
  • An unfiltered selection provides true peak and valley readings and aids in control applications.
  • A batch average filter selection averages each 16 conversions.
  • An adaptive moving average filter selection provides a choice of 8 time constants from 80 ms to 9.6 seconds. When a significant change in signal level occurs, the filter adapts by briefly switching to the shortest time to follow the change, then reverts back to its selected time constant. An Auto setting selects the time constant selection based on signal noise.

Peak and valley values are automatically captured. These may be displayed via a front panel pushbutton command or control signal at the rear connector, or be transmitted as serial data.

Two rear panel control Inputs (CMOS/TTL levels, logic 0 = tied to digital ground, logic 1 = open) or dry contacts that can be set to control / activate 14 meter commands.

An (isolated) 5, 10, 12, or 24 Vdc excitation output is standard to power transducers or two-wire transmitters. Ratiometric operation, which automatically compensates for changes in the applied excitation, is jumper selectable for applications, such as bridges, where the signal to be measured is proportional to the excitation level.

Display
Readout 6 LED digits, 7-segment, 14.2 mm (.56"), red or green
Display Range -999,999 to +999,999, XXXXEX scientific notation beyond 999,999
Zero Adjust -999,999 to +999,999
Span Adjust 0 to ±999,999
Indicators Four LED lamps
Analog Input (V-to-F signal conditioner)
Signal Types 0-1 mA, 4-20 mA, 0-10V
Conversion Technique Inverse period applied to 10 kHz- 110 kHz
Update Rate 50 ms (max)
Gate Time Selectable 10 ms to 199.99 s
Recalibration: All ranges are calibrated at the factory. Recalibration is recommended every 12 months.
Power Supply Boards (one required)
Voltage, standard 85-264 Vac or 90-300 Vdc
Voltage, optional 12-32 Vac or 10-48 Vdc
Frequency DC or 47-63 Hz
Power consumption 1.2W @ 120 Vac, 1.5W @ 240 Vac, 1.3W @ 10 Vdc, 1.4W @ 20 Vdc,
   (typical, base meter) 1.55W @ 30 Vdc, 1.8W @ 40 Vdc, 2.15W @ 48 Vdc
Power Isolation 250V rms working, 2.3 kV rms per 1 min test
Excitation Output (standard)
5 Vdc 5 Vdc ± 5%, 100 mA (jumper selectable)
10 Vdc 10 Vdc ± 5%, 120 mA (jumper selectable)
12 Vdc 12 Vdc ± 5%, 100 mA (jumper selectable)
24 Vdc 24 Vdc ± 5%, 50 mA (jumper selectable)
Output Isolation 50 Vdc from signal ground
Analog Output Boards (one optional)
Output Levels 4-20 mA, 0-20 mA, 0-10V, -10 to +10V (single-output option)
Current compliance 4-20 mA, 0-20 mA, 0-10V (dual-output option)
Voltage compliance 2 mA at 10V ( > 5 kΩ load)
Scaling 12V at 20 mA ( < 600 Ω load)
Resolution Zero and full scale adjustable from -99999 to +99999 16 bits (0.0015% of full scale)
Isolation 250V rms working, 2.3 kV rms per 1 min test (dual analog outputs share the same ground)
Relay Output Boards (one required for batch control)
Dual magnetic relays 2 Form C, 10A max, 440Vac or 125Vdc max, 2500VA or 300W
Quad magnetic relays 4 Form A (NO), 10A max, 440Vac or 125Vdc max, 2500VA or 300W
Dual solid state relays 2 Form A (NO), AC or DC, 0V - 400V, 120Ma, 35Ohms (max at On-State)
Quad solid state relays 4 Form A (NO), AC or DC, 0V - 400V, 120Ma, 35Ohms (max at On-State)
Relay commons Isolated commons for dual relays or each pair of quad relays
Relay isolation 250V rms working, 2.3 kV rms per 1 minute test
Relay latching modes Latching or non-latching
Relay active modes Active on or off, active high or low
Hysteresis modes QA passband mode, split hysteresis, span hysteresis
Communication Boards (one optional)
Board Selections RS232RS485 with dual RJ11 connectors, RS485 with dual RJ45 connectors, USB, High-Speed Ethernet, USB-to-RS485 gatewayHigh-Speed Ethernet-to-RS485 gateway, WiFi with built-in antenna plus USB & RS485, WiFi with external antenna plus USB & RS485
Protocols Laurel Custom ASCII (serial), Modbus RTU (serial), Modbus TCP (Ethernet or WiFi)
Digital Addresses 247 (Modbus), 31 (Laurel ASCII),
Isolation 250V rms working, 2.3 kV rms per 1 min test
Environmental
Operating Temperature -40°C to 70°C (-40°F to 158°F)
Storage Temperature -40°C to 85°C (-40°F to 185°F)
Relative Humidity 95% at 40°C, non-condensing
Protection NEMA-4X (IP-65) when panel mounted
Signal Connections
Signal connections to Laurel pulse input batch controller
Mechanical
Enclosure 1/8 DIN, high impact plastic, UL 94V-0, color: black
Mounting 1/8 DIN panel cutout required: 3.622" x 1.772" (92 mm x 45 mm).
Dimensions 4.68" x 2.45" x 5.64" (119 mm x 62 mm x 143 mm) (W x H x D)
Maximum panel thickness 4.5 mm (0.18")
Tightening Torque - Connectors Screw terminal connectors: 5 lb-in (0.56 Nm)
Tightening Torque - Pawls Digital Panel Meter Case Pawls: 5 lb-in (0.56 Nm)
Weight of base meter 210 g (7.4 oz) typical (DPM, counter, timer, 6-digit remote display)
Weight of option boards 30 g (1.0 oz) typical per board (analog output, relay output, communications)
General
Programming Methods Four front panel buttons or via Laurel's free Instrument Setup Software, which runs on a PC under MS Windows. 
Security Lockout options include using the front panel buttons, the free Instrument Setup Software, or a hardware jumper.
Warranty 3 years parts & labor
Recalibration: All ranges are calibrated at the factory. Recalibration is recommended every 12 months.

Free Instrument Setup Software for Series 2 Laureates

Digital Panel Meter Laurel Electronics Digital Transmitters
1/8 DIN Digital Panel Meters DIN Rail Transmitters

Free Downloadable Windows-based Instrument Setup (IS) software (Data Interface Board Required) for use with our programmable Digital Panel Meters, Scale Meters, Counters, Timers, Remote Displays, and Transmitters, are an easy method to set up Laureate 1/8 DIN digital panel meters, counters, timers, remote displays, and DIN-rail transmitters, as explained in the Instrument Setup Software Manual. Laureate 1/8 DIN instruments can also be set up from the front panel, as explained in their respective Owners Manuals. Instrument Setup software is of benefit whether or not the PC is connected to the instrument.

  • When the PC is connected to the instrument, Instrument Setup software can retrieve the setup file from the instrument or open a default setup file or previously saved setup file from disk View Setup, then provides graphical user interface (GUI) screens with pull-down menus applicable to input, display, scaling, filtering, alarms, communications, analog output, and front panel lockouts. Fields that are not applicable to the instrument as configured are either left out or grayed out. Clicking on any item will bring up a detailed Help screen for that item. After editing, the setup file can be downloaded, uploaded to the instrument, or saved to a disk. The same setup file can then be downloaded into multiple instruments.
  • When the PC is not connected to the instrument, the above GUI screens can be used to set up a virtual instrument. The setup file can then be saved to disk. Switching toView Menu then brings up a screen with the required front panel programming steps. This view can be printed out for use at the instrument site and to serve as a hard copy record.

    Download Free Instrument Setup Software


Installation

Set User Account Control (UAC) of MS Windows to "Never notifiy me" so that Instrument Setup Software can create directories. The UAC change screen can be reached as follows:

  • Under Windows 7, click on the Windows Start button in the lower left of the desktop and enter "UAC" in the search field.
  • Under Windows 8, navigate to Control Panel, then to the "User Accounts and Family Safety" section, and click on "Change User Account Control Settings."
  • Under Windows 10, click on the Windows Start button in the lower left of the desktop, then on "Settings", and enter "UAC" in the search field.
  • Reboot your computer for the changed UAC setting to take effect.
Meter board with USB Type-B connector

RJ11-to-DB9 cable with rear view of DB9 connector to PC

Laurel USB cable, P/N CBL05

RS232 cable, meter to PC, P/N CBL01

Laureate 1/8 DIN Laureate instruments must be equipped with a serial communications board and be connected to the computer via a serial communications cable. The connection can be via RS232, RS485, USB or Ethernet. Following setup, the serial communications board may be removed from the instrument if desired. The wiring of the RS232 cable is illustrated above with end views of the two connectors.

Laureate LT Series transmitters come standard with a 3-wire serial interface, which can be jumpered for RS232 or RS485.
Laureate LTE Series transmitters come standard with an Ethernet interface.

Meter Setup Screens

Click on any of the reduced screens below for a full-size screen view, then click on the Back button of your browser to return to this page. The screens examples below are for a fully-loaded Series 2 Digital Panel Meter (DPM), which is connected to the PC via RS232. If the meter is a Series 1 meter (pre-2007), this is sensed by the software, and somewhat different screens are brought up. Please see Series 1 setup screens.

Laurel Dual Channel Pulse Input Rate Meter
Welcome Screen
From the computer desktop, click on Start > Programs > IS2 > IS2. Or click on the IS icon on your desktop. This splash screen will be displayed for three seconds. The software revision number is in the lower right.
more
Setup Screen 02s for Digital Panel Meters and Digital Transmitters
Communications Selection Screen
Specify your desired communication protocol and the serial communications bus type, which should match the jumper setup of the instrument. Select None if the PC is not connected to the instrument.
more
Setup Screen 3 for Digital Panel Meters and Digital Transmitters
Establish Communications Screen
If you selected RS-232, you will be asked to specify the PC Com Port and Baud Rate, which should match the jumper setup of the instrument. Click on Establish. With the right settings, the Communications Established field will light up in green, and the Meter Type will be recognized. If so, click onMain Menu.
more
Setup Screen 4 for Digital Panel Meters and Digital Transmitters
Main Menu Screen
Click on File > Default Setup to retrieve the default setup file from disk for your type of meter. Click on File > Open Setupto retrieve a previously saved setup file from disk or on File > Save Setup to save your edited setup file to disk. Click onDPM > Get Setup to retrieve the setup file from your meter or on DPM > Put Setup to download your edited setup file into the meter.
more
Setup Screen 5 for Digital Panel Meters and Digital Transmitters
DPM Input + Display Setup Screen
From the Main Menu, click on View > Setup, then on theInput+Display tab. You can now specify the meter hardware, signal type, display mode, and functions of control inputs A and B. Clicking on any item brings up a pull-down menu with the available choices.
more
Setup Screen 6 for Digital Panel Meters and Digital Transmitters
DPM Scaling Setup Screen
Click on the Scaling tab, which provides three scaling methods to relate the signal to the displayed reading: 1) Scale and Offset method, 2) Coordinates of two points method, and 3) Reading Coordinates of Two Points method. The last method uses actual high and low signals, and the computer will prompt you.
more
Setup Screen 7 for Digital Panel Meters and Digital Transmitters
DPM Filter Setup Screen
Click on the Filter tab, which allows you to specify the digital filter time constant (if any), the adaptive filter threshold, and whether Peak / Valley values are filtered or unfiltered. As for all setup screens, clicking on the F1 key while an item is highlighted brings up a Help screen for that item, as illustrated.
more
Setup Screen 8 for Digital Panel Meters and Digital Transmitters
DPM Relay Alarms Setup Screen
Click on the Relay Alarms tab, which allows you to set up Alarms 1 and 2 for the optional dual relay output board. Clicking on any of the four numeric fields changes these to green and brings up a special field to enter the desired numeric value, which is tied to the displayed reading.
more
Setup Screen 9 for Digital Panel Meters and Digital Transmitters
DPM Communications Setup Screen
Click on the Communications tab so set up serial communications. In particular, you can special the Serial Protocol and the meter address if multiple meters are to be addressed on the same serial data line.
more
Setup Screen 10 for Digital Panel Meters and Digital Transmitters
DPM Analog Output Setup Screen
Click on the Analog Out tab so set up the optional analog output board. Three output ranges are selectable, the endpoints of which can be tied to user-specified High and Low readings.
more
Setup Screen 11 for Digital Panel Meters and Digital Transmitters
DPM Lockouts Setup Screen
Click on the Lockouts tab to check off menu items which will no longer be accessible from the front panel of the meter. This will simplify meter operation and prevent unintended setup changes.
more

Meter Setup Utilities

Setup Screen 12 for Digital Panel Meters and Digital Transmitters
DPM Front Panel Setup Screen
As an aid to programming the meter from the front panel when a serial connection is not available, you can return to the Main Menu and click on View > Menu. The required sequence of front panel screens will then be displayed. Click on any step in the sequence for the meaning of each digit, as illustrated for the FILtEr step. For a hardcopy, simply press on Print.
more
Setup Screen 13 for Digital Panel Meters and Digital Transmitters
DPM Jumper Setup Screen
Specify your desired communication protocol and the serial communications bus type, which should match the jumper setup of the instrument. Select None if the PC is not connected to the instrument.
more
Setup Screen 14 for Digital Panel Meters and Digital Transmitters
DPM Jumper Setup Screens
Click on any of the displayed plug-in boards, and you will be presented with the jumper positions and electrical connections for your selected board. This minimizes the need to refer to the printed manual.
more
Setup Screen 15 for Digital Panel Meters and Digital Transmitters
DPM Commands Screen
This page allows you set up external input, serial communications, an analog output proportional to the display (optional), and lockouts for Laureate digital counters. The grayed out area at the top right of the screen applies to Laureate remote displays.
more
Graphical Output Screens (not available with Ethernet)

From the Main Menu, click on Readings if your PC is connected to the meter. A pull-down menu then offers three choices: ListPlot and Graph.

  • List presents the latest readings in a 20-row by 10-column table. Press Pause at any time to freeze the display. This is one method to capture peak readings.   
  • Plot generates a plot of readings vs. time in seconds. It effectively turns the DPM-PC combination into a printing digital oscilloscope.
    more 
  • Graph generates a histogram where the horizontal axis is the reading and the vertical axis is the number of occurrences of readings. The display continually resizes itself as the number of readings increases.
    more
Setup Screen 18 for Digital Panel Meters and Digital Transmitters
DPM Calibration Screens
Click on the Scaling tab, which provides three scalClick on the Scaling tab, which provides three scaling methods to relate the signal to the displayed reading: 1) Scale and Offset method, 2) Coordinates of two points method, and 3) Reading Coordinates of Two Points method. The last method uses actual high and low signals, and the computer will prompt you.
more
Setup Screen 19 for Digital Panel Meters and Digital Transmitters
Frequency Meter Calibration Screen
Calibration of the quartz crystal of the Laureate frequency meter requires the input of a known frequency from a calibrator. Apply the frequency, then enter the frequency in Hertz. Calibration will be automatic, with storage of the calibration factor stored in non-volatile memory.
more

 

Laureate™ 1/8 DIN Case For Laureate Digital Panel Meters, Counters, Timers & Remote Displays

Laurel panel meter case

Key Features

  • Meets 1/8 DIN Standard.
  • Installs from front of panel.
  • Short depth behind the panel: only 4" (102 mm) plus connectors.
  • Understated 0.157" (4 mm) thick bezel.
  • Meets NEMA 4X (IP-65) for high-pressure wawshdon when panel mounted.
  • Screw clamps connectors meet VDE / IEC / UL / CSA safety standards.
  • Rugged GE Lexan® housing material.
  • Safety certified per EN 61010-1.
CE CertifiedRoHs CertifiedETL Certified

Dimensions

Mechanical specifications of Laureate digital panel meters and electronic counters

Maximum panel thickness: 4.5 mm (0.18")
Weight of base meter:
210 g (7.4 oz) typical (DPM, counter, timer, 6-digit remote display)
Weight of option boards: 30 g (1.0 oz) typical per board (analog output, relay output, communications)
Tightening Torque - Connectors: Screw terminal connectors: 5 lb-in (0.56 Nm)
Tightening Torque - Pawls: Digital Panel Meter Case Pawls: 5 lb-in (0.56 Nm)
Dimensioned CAD assembly drawings in EPRT, STEP, x_t. dwg, pdf file formats: Laureate-meter-case.zip (zipping prevents browser from opening CAD files as text files).

Panel Mounting

Mechanical Panel Mounting GuideSlide the meter into a 45 x 92 mm 1/8 DIN panel cutout. Ensure that the provided gasket is in place between the front of the panel and the back of the meter bezel. The meter is secured by two pawls, each held by a screw, as illustrated. Turning each screw counterclockwise extends the pawl outward from the case and behind the panel. Turning each screw clockwise further tightens it against the panel to secure the meter.

Turning each screw counterclockwise loosens the pawl and retracts it into its well. This position allows installed meter to be removed from their panel, or new meters to be installed in a panel. Do not remove the screws from their pawls. Doing so would cause the screw and pawl to fall off and likely get lost. Do not overtighten so as not to damage the plastic parts.

 

Drum Filling Application Utilizing Two Relay Outputs
Drum filling batch controller application utilizing two relay outputs In this drum filling application, the Laureate pulse-input batch controller utilizes uses its two relays to control a pump. The Prewarn relay slows down the pump near the preset to avoid overshoot. The Batch relay stops the pump at the preset.
Controlling Chemical Mixing of Materials
Controlling mixing of materials using two Laureate batch controllers Multiple Laureate batch controllers can be used in combination to control the mixing of materials in the proper ratio. Each feed line is equipped with its own pump, flowmeter, and Laureate. Controller setup and monitoring of the mixing operation are facilitated by optional serial communications. RS485 allows a single data line to handle multiple controllers.
Up-Counting Batch Control
Up-counting batch controller using the Laureate Batch Controller In up-counting batch control, the Laureate counts up from zero to a preset maximum. A prewarn level is available to slow down filling near the preset to avoid overshoot. A time delay can be programmed from the end of each batch to the start of the next batch.
Down-Counting Batch Control
Down-counting batch control using the Laureate Batch Controller In down-counting batch control, the Laureate counts down from the preset maximum to zero. A prewarn level is available to slow down filling or emptying near zero. Again, a time delay can be programmed from the end of each batch to the start of the next batch.
Discrete Filling and Batch Counting
Discrete filling and batch counting using the Laureate Batch Controller The Laureate batch controller is ideal for discrete manufacturing as well as repetitive fill operations. In this example, the Laureate counts bottles which it then groups into sixpacks. Its Grand Total capability can be used to track bottles or sixpacks.

 

Batch Controller Digital Panel Meter Frequently Asked Technical Questions

They are the same, but “Batch Control” is a user selectable operating mode of the Extended Laureate counter with the FR dual-channel pulse input signal conditioner board. The higher cost “Extended” versions of the Laureate counter (model numbers beginning with L7 or L8) offer programmable capabilities not offered by the Basic versions (model numbers beginning with L5 or L6). “Batch Control” enables specific features for repetitive fill operations. A relay board with 2 or 4 relays is also required in the counter to turn pumps and valves on or off.
The same signal from a pulse output flow sensor is applied in parallel to Channels A and B. Three values are tracked and can be separately displayed by pressing the RESET key: Item #1, the Batch Total; Item #2, the Grand Total of all batches or Number of Batches (selectable during setup); and Item #3, the Fill Rate. Using the dual relay board, relay #1 is used as the batch relay to control the main fill operation. Relay #2 can be assigned to another limit, such as pre-warn to slow filling near the setpoint, end-of-process, or rate alarm. The next fill operation can be programmed to be start after a specified gate time or upon receipt of an external contact closure input.
The displayed values for total or rate can be scaled to engineering units with a user selectable number of digits after the decimal point, such as 45.97 gallons, 0.267 gallons/min or 8.24 liters/sec. Scaling is normally done from the counter’s front panel but can also be done with Instrument Setup (IS) software if the counter is equipped with a communications board. With batch control, scaling normally converts pulse counts to units of volume, such as gallons, liters or cubic feet. Scaling normally converts input frequency in Hz flow rate in units of volume per second or minute.
When equipped with the FR dual channel pulse input signal conditioner board (P/N LSCDF), the Batch Controller accepts output pulses from a turbine flow meter. These can be voltage pulses from an active sensor or a magnetic pickup. The FR signal conditioner board can also be jumpered for contact closure inputs, signals from proximity switches with a PNP or NPN output, or high-level signals up to 250 Vac. When equipped with the VF voltage-to-frequency signal conditioner board (P/N LSCAF), the Batch Controller accepts 4-20 mA, 0-1 mA or 0-10V analog signals, as selected by jumpers.
The firmware of the Basic counter needs to be converted to an Extended counter. This can only be done at the factory. However, option boards like dual or quad relay boards, can be purchased separately be simply plugged in later. The presence of a new board and the type of board are automatically sensed by the meter’s firmware or by  Instrument Setup (IS) software. If you change boards, also change the model number on the meter label.
The Batch Controller is but one user-programmable function of the Laurel’s Extended counter. Other functions are independent rate or total one channels A and B, rate on A and total on B, arithmetic combinations of channels A and B, stopwatch, averaging timer, phase angle, duty cycle, and more, as described in the Laureate counter user manual.
The only thing which can be calibrated in a Laureate counter is the quartz crystal time base which is used for frequency or rate. Note that calibration is different from scaling. Calibration is used to bring readings in harmony with national standards, like those of the USA’s National Institute of Standards and Technology (NIST). Factory calibration sets the quartz crystal time base to an accuracy of 2 ppm (parts per million) but will change by a few ppm over time. It may never need to be redone for most industrial applications. Calibration is done at the factory by using a precision 100 kHz quartz crystal calibrator. Calibration can also be done in the field by applying a precision 100 kHz square wave signal from any precision frequency source, as explained in the 1-page "Counter Calibration" section of the user manual .

 

 

CAL-Digital

Certificate of Calibration

$65.00

DLS-XLOG2

XLog2 Data logging Software

$495.00

IPC

Splashproof Cover

$55.00

CON01

CON01 Connector

$75.00

CBL01

RS232 Cable for Meters

$35.00

CBL02

USB-to-RS232 Adapter Cable

$47.00

CBL04

RS232 Cable for LT Transmitters

$47.00

CBL05

USB Data Cable for Meters

$47.00

CBL06

USB-to-RS485 Adapter Cable

$47.00

CBL07

USB Programming & Data Cable

$47.00

CBL08

RS485 Splitter Cable

$33.00

CBL6

6-foot Power Cable

$41.00

CBL12

12-foot Power Cable

$47.00

Modular Design for Maximum Flexibility at Minimum Cost

All boards are isolated from meter and power grounds. Optional Plug-in-Play boards for communications and control include Ethernet, WiFi, serial communication boardsdual or quad relay boards, and an analog output board. Laureates may be powered from 85-264 Vac or optionally from 12-32 Vac or 10-48 Vdc. The display is available with bright red or green 0.56" (14.2mm) high LED digits. The 1/8 DIN case meets NEMA 4X (IP65) specifications from the front when panel mounted. Any setup functions and front panel keys can be locked out for simplified usage and security. A built-in 5, 10, 12, or 24 Vdc excitation supply can power transducers, eliminating the need for an external power supply. All power and signal connections are via UL / VDE / CSA rated screw clamp plugs.

The Laureate™ Series features modular design with up to 7 isolated plug-in boards, applicable to all Laureate 1/8 DIN Panel Meter.

Schematic for Digital Panel Meter

Modular Hardware

The design of the Laureate™ Series is modular for maximum flexibility at minimum cost. All boards are isolated from meter and power grounds. The base configuration for a panel meter or counter consists of a main module (with computer and plug-in display boards), a power supply board, and a signal conditioner board. Optional plug-in-play boards include an isolated setpoint controller board, an isolated analog output board, and an isolated digital interface board. Modular design and a choice of plug-in options allow the Laureate to be customized for a broad range of applications from simple monitoring to control and computer interface. There can be up to five plug-in boards in a 1/8 DIN Laureate.

Dual Board sets

Connecting Laureate Panel Meter to a Local Area Network (LAN)

Up to 30 Laureate Panel Meter and/or LT Transmitters can be configured for RS485 and daisy-chained to an LT Transmitter using Laurel’s High Speed Ethernet-to-RS485 converter board for seamless LAN integration. Alternatively, Laurel LTE series Ethernet transmitters can connect directly to a LAN via an Ethernet cable. Setup for both configurations is streamlined using Laurel’s free Instrument Setup Software, which simplifies node discovery and transmitter configuration.

Flexible Communication Options for Panel Meter

The Laureate Panel Meter can be equipped with Laurel communication boards to support various interfaces and protocols. These include serial interfaces with ASCII or Modbus RTU protocols, and Ethernet interfaces with web access, ASCII, or Modbus TCP/IP protocols, ensuring versatile connectivity for your commercial applications.

Laurel network with Ethernet-to-analog converter board

Ordering Guide
Part Number as Configured: L8112DVF2
Price as Configured: $872.00

Click on the Option Board Links for More Product Information

Base Item
$169.00
Display Color
$41.00
$41.00
Power (Isolated) $75.00
$115.00
Relay Output (Isolated)
$0.00
$101.00
$70.00
$128.00
$96.00
Analog Output (Isolated)
$0.00
$115.00
$172.00
Data Interface (Isolated)
$0.00
$81.00
$109.00
$135.00
$81.00
$135.00
$237.00
$259.00
$182.00
$204.00
$171.00
$193.00
$204.00
$226.00
Signal Input (Isolated)
$81.00
$81.00
$81.00
Part Number as Configured:
L8112DVF2
Price as Configured:
$872.00
Quantity:
- +
Extended Price:
$872.00

Understanding the Laureate™ 1/8 DIN Panel Meter Batch Controller for Analog Input

The Laureate™ 1/8 DIN Panel Meter batch controller can use the Laureate V-to-F analog signal conditioner for use with 4-20 mA, 0-1 mA, or 0-10V conditioned flow meter signals — an alternative to the pulse-input FR signal conditioner for applications where the flow transmitter outputs a standard analog process signal rather than raw pulses. Relay control is provided by two or four 8A contact relays, or two or four 120 mA AC/DC solid state relays, with fill operations repeating continually on a programmable delay from 10 ms to 199.99 seconds, or based on an external control input.

Batch Control With Conditioned Flow Signals

The analog-input batch controller uses the Laureate VF voltage-to-frequency converter signal conditioner board, which converts 4-20 mA, 0-1 mA, or 0-10V conditioned flow meter signals to a frequency between 10 kHz and 110 kHz. This lets the controller totalize flow, count up to a preset value, or count down to zero from a preset value for batch control — with one relay dedicated to ON/OFF batch control while the other is available to slow rate near setpoint or provide an alarm/control function based on rate or total.

Three Tracked Items

As with the pulse-input version, three items are tracked and can each be scaled to engineering units and displayed on the six-digit LED display: Item #1 is the current batch total (counting up from zero to preset, or down from preset to zero), Item #2 is grand total or number of batches, and Item #3 is flow rate.

Signal Conditioning Update Rate

Maximum update rate for the analog input is 50 ms, with gate time selectable from 10 ms to 199.99 seconds — this combination determines how quickly the meter's rate and total displays respond to a genuine change in the transmitter's analog signal.

Factory-Calibrated Accuracy

All signal conditioner board ranges are factory-calibrated, with calibration factors stored in an onboard EEPROM that can be scaled via software to accommodate external shunts — enabling field replacement of the signal conditioner board without recalibrating the meter. Factory recalibration is recommended annually.

Real-World Applications

  1. Drum Filling With Two Relay Outputs — a Prewarn relay slows the pump near the preset to avoid overshoot, while the Batch relay stops the pump at the preset.
  2. Controlling Chemical Mixing of Materials — multiple batch controllers, each with its own pump and flow transmitter, work together to mix materials in the proper ratio, with RS485 letting a single data line handle multiple controllers.
  3. Up- or Down-Counting Batch Control — counting up from zero to a preset maximum, or down from a preset maximum to zero, with a prewarn level and programmable inter-batch delay available in either direction.

Analog Input Batch Controller — Additional Technical Questions

What's actually different about using a V-to-F analog signal conditioner instead of the FR pulse signal conditioner for batch control?

The FR board reads pulses directly from a turbine flow meter or similar pulse-output sensor. The VF board instead accepts a conditioned analog process signal (4-20 mA, 0-1 mA, or 0-10V) — typically from a transmitter that has already converted its raw sensor signal into a standard analog process signal — and internally converts that to a frequency (10-110 kHz) before applying the same inverse-period measurement technique used elsewhere in the Laureate line.

Which of the three analog input types (4-20 mA, 0-1 mA, 0-10V) should I choose for my batch controller?

The choice depends entirely on what output type your flow transmitter or transducer actually provides — the VF board is jumper-selectable between the three, so it should be matched to the transmitter's rated output type rather than chosen independently. 4-20 mA is the most common choice for long cable runs due to its inherent noise immunity.

Does the analog-input version need excitation power for the connected transmitter, or does that come separately?

The meter provides a built-in isolated excitation output (5, 10, 12, or 24 Vdc, jumper-selectable) that can power a connected transducer or two-wire transmitter directly, eliminating the need for a separate power supply for the field device.

How does the update rate on the analog input version compare to the pulse input version?

The analog input's maximum update rate is 50 ms, versus the pulse-input FR board's update rate that can reach 25 readings per second (roughly 40 ms) at its fastest gate time — the two are broadly comparable, but the analog version's update rate is fixed at that 50 ms maximum regardless of the actual analog signal's characteristics, since it's governed by the V-to-F conversion and inverse-period measurement stages together.

Can a single batch controller be reconfigured between pulse input and analog input later, or is that a hardware decision made at order time?

This is a hardware decision — the FR and VF are two different physical signal conditioner boards, so switching between pulse-input and analog-input operation requires physically swapping the signal conditioner board, not just a software or firmware change.

What relay hysteresis modes are available to prevent the batch relay from chattering right at the target?

QA passband mode, split hysteresis, and span hysteresis are all available on the relay output boards, controlling how far the reading has to move away from a setpoint before the relay changes state again — the same relay hardware and hysteresis options apply whether the controller is configured for pulse or analog input.

Is the analog input batch controller's accuracy tied to the meter's own specs, or to the connected transmitter?

Both, in combination — the meter's own signal conditioning and inverse-period measurement contribute their own accuracy, but the overall batching accuracy is fundamentally limited by the accuracy and calibration of whatever transmitter is generating the 4-20 mA, 0-1 mA, or 0-10V signal in the first place. A highly accurate meter can't compensate for an inaccurate or poorly calibrated field transmitter.

Can the analog input batch controller totalize a flow signal that's already been square-root extracted by the transmitter?

Yes, as long as the transmitter's output signal is already linearized to flow (rather than raw differential pressure), the meter can totalize it directly. It's important to confirm whether square root extraction is being applied once, either in the transmitter or in the meter, but not both, since applying it twice would distort the resulting flow calculation.

What happens to the batch total and grand total if power is lost mid-fill on the analog input version?

Totals are stored in non-volatile memory and retained through a power interruption, the same as on the pulse-input version, though the specific recovery behavior for a batch actively in progress at the moment of power loss should be confirmed against the meter's configuration for that application.

Can the analog batch controller also serve as an isolated 4-20 mA transmitter for another system, in addition to controlling the batch?

Yes, with the optional isolated analog output board, the meter can retransmit rate or total as an isolated 4-20 mA or 0-10V signal, letting a separate PLC or recorder independently monitor the process value while the meter's own relay logic handles batch control.

Analog Input Batch Controller Questions From Online Engineering Sources

Should I use a pulse output or a 4-20 mA output flow meter for controlling batch flow rate with a valve or VFD?

Real field discussion on this generally favors 4-20 mA specifically for closed-loop rate control — a 4-20 mA signal integrates directly into a PID control loop for driving a valve or variable-speed pump, whereas pulse output is more commonly reserved for totalizing when a HART or 4-20 mA option isn't available. Some practitioners specifically note trusting a totalizer pulse input over an analog signal for absolute accuracy, using the pulse count as a cross-check against the 4-20 mA reading rather than relying on either exclusively.

What is turndown ratio, and why does it matter for a flow transmitter feeding a batch controller?

Turndown ratio is the range between a transmitter's maximum and minimum flow rate that it can still measure accurately, and it directly determines whether a transmitter can handle both a batch's low-flow dribble stage and its high-flow bulk-fill stage without losing accuracy at one end. A transmitter with insufficient turndown for the batch's actual flow range can produce accuracy errors that scale dramatically at the low end — documented examples show low-end accuracy degrading to tens of percent error when a transmitter is pushed well below its rated turndown minimum.

Why would a differential-pressure-based flow transmitter be a poor choice for a batch process with a wide dribble-to-bulk flow range?

DP-based flow measurement (such as an orifice plate) has documented turndown ratios as low as roughly 3:1, since flow is proportional to the square root of differential pressure, meaning accuracy degrades sharply at low flow. For a batch process needing to measure reliably across a wide range — from a slow dribble stage up to full bulk-fill flow — a technology with much higher turndown (such as magnetic or turbine flow measurement) is generally the better-documented choice.

What is "double extraction," and how could it silently corrupt my batch total?

This is a specifically documented configuration error: if a differential-pressure transmitter is configured to apply square root extraction internally, and the receiving device (such as this batch controller) also applies square root extraction to the same signal, the result looks approximately correct near the middle of the range but deviates dramatically at low and high flow. Verifying that square root extraction is applied in exactly one place in the signal chain — either the transmitter or the receiving meter, never both — is essential to catching this before it corrupts batch totals.

Does a flow transmitter's accuracy stay the same over time, or does it need periodic reverification for batch service?

Documented transmitter performance data shows a freshly calibrated transmitter meets its rated accuracy on day one, but stability drift (typically referenced to the transmitter's upper range limit rather than the actual span in use) accumulates over roughly a 12-month period, adding a meaningful error component. This drift contribution becomes proportionally larger the higher the turndown ratio being used, which is a documented reason to plan periodic recalibration intervals specifically for high-turndown transmitters used in precision batching.

Can I safely extend a transmitter's configured range beyond its rated turndown just by reconfiguring the LRV/URV in a smart transmitter?

No — this is a specifically documented pitfall: modern smart transmitters technically allow entering nearly any lower and upper range values, but doing so doesn't guarantee accurate measurement if the resulting turndown exceeds the transmitter's actual rated capability. Exceeding the manufacturer's rated turndown ratio voids the transmitter's accuracy specification, even though the device will still output a signal.

Why does my flow rate fluctuate rapidly and erratically when two pumps run simultaneously, feeding the same transmitter?

This has been documented as a real field issue, and while root causes can vary by installation, it's frequently linked to turbulence or pressure interaction at the transmitter's sensing point when multiple pumps operate together, rather than a fault in the transmitter or receiving meter itself. Reviewing transmitter placement relative to pump interaction points and confirming adequate straight-pipe run upstream of the sensor are standard troubleshooting steps for this specific multi-pump interference pattern.

How much cable length can a 4-20 mA signal reliably run before I should switch to a digital signal for a remote batch controller installation?

Industry guidance generally recommends keeping 4-20 mA current loop runs within roughly 100 meters for reliable performance, with longer distances better served by a digital communication protocol (such as RS-485) instead — current loop signals resist voltage-drop-related error far better than voltage-based signals, but very long runs still introduce practical limitations worth planning around for a remote batching installation.