Panel Meters for AC Phase Angle and AC Power Factor Applications P/N L7020DFR

Panel Meters for AC Phase Angle and AC Power Factor Applications

Price: $629.00
  • P/NL7020DFR
- +

Features

  • Programmable to read phase angle or power factor with two waveshapes of identical period
  • Phase angle resolution of 1°, 0.1° or 0.01° and accuracy of 0.03° at AC line frequency
  • Power factor from 1.000 to 0.000 with sinusoidal signals
  • Accepts AC signals from 1 Hz to 10 kHz at voltages up to 250 Vrms
  • Transmits phase angle between two AC wave shapes of similar period
  • Transmits power factor from 1.000 to 0.000 with sinusoidal signals
  • For frequencies from 0.005 Hz to 10 kHz, voltages from 10 mV to 250 Vac
  • Digital span adjust from 0 to ±999,999, zero adjust from -999,999 to +999,999
  • Front panel scalable: to ±999,999 for use with current shunts
  • 1/8 DIN size with bright red or green 0.56" (14.2mm), high LED digits
  • Transducer excitation output, 5, 10, 12, or 24 Vdc (isolated)
  • Power 85-264 Vac / 90-300 Vdc or 10-48 Vdc / 12-32 Vac (isolated)
  • Operating temperature from -40°C to 70°C  (-40°F to 158°F)
  • Wide choice of Plug-in-Play options:
    - 2 or 4 relays, mechanical or solid state, for alarm or control (isolated)
    - 1 or 2 Analog output, 4-20 mA, 0-20 mA, 0-10V, or -10V to +10V (isolated)
    - Communications: Ethernet, WiFi, USB, RS232, RS485 (isolated)

The Laureate™ 1/8 DIN Panel Meters for phase angle & power factor meter

computes phase angle θ by timing zero crossings of two signals applied to Channels A and B. The phase angle range is selectable as 0° to 360° or -180° to +180°. Resolution is selectable as 1°, 0.1° or 0.01°. Typical accuracy is 0.01%  from 1 Hz to 100 Hz, 0.1%  at 1 kHz, and 1%  at 10 kHz.
Phase angle measurement by digital phase meter
  • Phase angle in degrees indicates the phase lead or lag between two periodic signals of the same period, as determined from their zero crossings. These two signals will typically be the voltage and current applied to a load. As illustrated, the phase angle θ in degrees is +360*P1/P.

AC Power Factor Measurement

  • The power factor of an AC power system is the ratio of real power in watts (W) divided by apparent power in volt-amperes (VA). For sinusoidal signals differing by a phase angle θ, power factor is cos(θ).
  • The Laureate™ Phase Angle & Power Factor Meter computes power factor as cos(θ) from phase angle θ. Power factor readings can range from 1.000 to 0.000 with three decimal places and an accuracy of 0.1%  for sinusoidal signals at 50/60 Hz power line frequency. While power factor is always positive, the panel meters artificially assigns a minus sign to power factor for negative phase angles, and it sets power factor to 0 for phase angles greater than 90°.

Laureate Panel Meters are easily programmed with Laurel’s free Instrument Setup Software, downloadable from our website and compatible with Windows PCs, requiring a data interface board for setup.

All signal conditioner board ranges are factory-calibrated, with calibration factors for each range securely stored in an onboard EEPROM. These factors can be scaled via software to accommodate external shunts, enabling field replacement of signal conditioner boards without necessitating recalibration of the associated panel meters. For optimal accuracy, factory recalibration is recommended annually. All Laurel Electronics instruments undergo factory calibration using the industry-leading Fluke calibrators, which are recalibrated yearly and certified traceable to national standards, ensuring the highest level of precision and reliability.

The Extended DPM Version Provides Capabilities Beyond Those of the Standard DPM Counter:

  • Custom curve linearization. Exceptionally accurate custom curve linearization is achievable, for example to linearize the low end of turbine flow meters. For setup, up to 180 data points can be input into a spreadsheet or text file by the user. The computer then calculates spline fit segments, which are downloaded into the panel meters via RS232. The linearized rate can then be totalized by the Extended counter.

Designed for flexibility

The Laureate Phase Angle & Power Factor Panel Meters utilize the Laureate Extended counter main board and the FR dual-channel signal conditioner board, which accepts AC signals from 12 mV p-p to 250 Vrms.

Digital signal filtering modes can be selected to ensure stable readings in electrically noisy environments.
  • An unfiltered selection provides true peak and valley readings and aids in control applications.
  • A batch average filter selection averages each 16 conversions.
  • An adaptive moving average filter selection provides a choice of 8 time constants from 80 ms to 9.6 seconds. When a significant change in signal level occurs, the filter adapts by briefly switching to the shortest time to follow the change, then reverts back to its selected time constant. An Auto setting selects the time constant selection based on signal noise.

Peak and valley values are automatically captured. These may be displayed via a front panel pushbutton command or control signal at the rear connector, or be transmitted as serial data.

Two rear panel control Inputs (CMOS/TTL levels, logic 0 = tied to digital ground, logic 1 = open) or dry contacts that can be set to control / activate 14 meter commands.

An (isolated) 5, 10, 12, or 24 Vdc excitation output is standard to power transducers or two-wire transmitters. Ratiometric operation, which automatically compensates for changes in the applied excitation, is jumper selectable for applications, such as bridges, where the signal to be measured is proportional to the excitation level.

AC Power Factor Meter & AC Phase Angle Meter

Phase Angle Mode
Item Displayed Phase angle difference between two waves of same period
Display Units 1°, 0.1°, 0.01°
Frequency Range 0.005 Hz to 10 kHz
Resolution 0.01°, 1 Hz to 100 Hz; 0.1° at 1 kHz; 1° at 10 kHz
Accuracy 0.05° at 50 or 60 Hz
Maximum Timing Interval 200 sec
Power Factor Mode
Item Displayed Power factor between two sine waves of same period
Display Units 1.000 to 0.000
Polarity Negative sign indicates negative phase angle
Frequency Range 0.005 Hz to 10 kHz
Accuracy 0.1% at power line frequencies
Update Rate
Timing Interval Gate time + 30 ms+ 0-2 signal periods
Gate Time Selectable 10 ms to 199.99 s
Time Before Zero Out Selectable 10 ms to 199.99 s (to indicate loss of signal)
Display
Readout 6 LED digits, 7-segment, 14.2 mm (.56"), red or green.
Range -999,999 to +999,999
Indicators Four LED lamps
Inputs
Signal ranges Nine AC signal ranges from 12 mVp-p to 250 Vac
Signal ground Common ground for channels A & B
Noise filter 1 MHz, 30 kHz, 250 Hz (jumper selectable) + digital filter
Recalibration: All ranges are calibrated at the factory. Recalibration is recommended every 12 months.
Power Supply Boards (one required)
Voltage, standard 85-264 Vac or 90-300 Vdc
Voltage, optional 12-32 Vac or 10-48 Vdc
Frequency DC or 47-63 Hz
Power  consumption (typical, base meter) 1.2W @ 120 Vac, 1.5W @ 240 Vac, 1.3W @ 10 Vdc, 1.4W @ 20 Vdc, 1.55W @ 30 Vdc, 1.8W @ 40 Vdc, 2.15W @ 48 Vdc
Power Isolation 250V rms working, 2.3 kV rms per 1 min test
Excitation Output (standard)
5 Vdc 5 Vdc ± 5%, 100 mA (jumper selectable)
10 Vdc 10 Vdc ± 5%, 120 mA (jumper selectable)
12 Vdc 12 Vdc ± 5%, 100 mA (jumper selectable)
24 Vdc 24 Vdc ± 5%, 50 mA (jumper selectable)
Output Isolation 50 Vdc from signal ground
Analog Output Boards (one optional)
Output levels 4-20 mA, 0-20 mA, 0-10V, -10 to +10V (jumper selectable)
4-20 mA, 0-20 mA, 0-10V (dual-output option)
Current compliance 2 mA at 10V ( > 5 kΩ load)
Voltage compliance 12V at 20 mA (< 600 Ω load)
Scaling Zero and full scale adjustable from -99999 to +99999
Resolution 16 bits (0.0015% of full scale)
Isolation 250V rms working, 2.3 kV rms per 1 min test
Relay Output Boards (one optional)
Dual magnetic relays 2 Form C, 10A max, 440Vac or 125Vdc max, 2500VA or 300W
Quad magnetic relays 4 Form A (NO), 10A max, 440Vac or 125Vdc max, 2500VA or 300W
Dual solid state relays 2 Form A (NO), AC or DC, 0V - 400V, 120Ma, 35Ohms (max at On-State)
Quad solid state relays 4 Form A (NO), AC or DC, 0V - 400V, 120Ma, 35Ohms (max at On-State)
Relay commons Isolated commons for dual relays or each pair of quad relays
Relay isolation 250V rms working, 2.3 kV rms per 1 minute test
Relay latching modes Latching or non-latching
Relay active modes Active on or off, active high or low
Hysteresis modes QA passband mode, split hysteresis, span hysteresis
Communication Boards (one optional)
Board selections RS232RS485 with dual RJ11 connectors, RS485 with dual RJ45 connectors, USB, Ethernet, USB-to-RS485 gatewayEthernet-to-RS485 gateway, WiFi with built-in antenna plus USB & RS485, WiFi with external antenna plus USB & RS485
Protocols Laurel Custom ASCII (serial), Modbus RTU (serial), Modbus TCP (Ethernet or WiFi)
Digital addresses 247 (Modbus), 31 (Laurel ASCII),
Isolation 250V rms working, 2.3 kV rms per 1 min test
Environmental
Operating temperature -40°C to 70°C (-40°F to 158°F)
Storage temperature. -40°C to 85°C (-40°F to 185°F)
Relative humidity 95% at 40°C, non-condensing
Protection NEMA-4X (IP-65) when panel mounted
Electrical Connections
Signal connections to Laurel pulse input batch controller
Mechanical
Enclosure 1/8 DIN, high impact plastic, UL 94V-0, color: black
Mounting 1/8 DIN panel cutout required: 3.622" x 1.772" (92 mm x 45 mm).
Dimensions 4.68" x 2.45" x 5.64" (119 mm x 62 mm x 143 mm) (W x H x D)
Maximum panel thickness 4.5 mm (0.18")
Tightening Torque - Connectors Screw terminal connectors: 5 lb-in (0.56 Nm)
Tightening Torque - Pawls Digital Panel Meter Case Pawls: 5 lb-in (0.56 Nm)
Weight of base meter 210 g (7.4 oz) typical (DPM, counter, timer, 6-digit remote display)
Weight of option boards 30 g (1.0 oz) typical per board (analog output, relay output, communications)
General
Programming Methods Four front panel buttons or via Laurel's free Instrument Setup Software, which runs on a PC under MS Windows. 
Security Lockout options include using the front panel buttons, the free Instrument Setup Software, or a hardware jumper.
Warranty 3 years parts & labor
Recalibration: All ranges are calibrated at the factory. Recalibration is recommended every 12 months.

Free Instrument Setup Software for Series 2 Laureates

Digital Panel Meter Laurel Electronics Digital Transmitters
1/8 DIN Digital Panel Meters DIN Rail Transmitters

Free Downloadable Windows-based Instrument Setup (IS) software (Data Interface Board Required) for use with our programmable Digital Panel Meters, Scale Meters, Counters, Timers, Remote Displays, and Transmitters, are an easy method to set up Laureate 1/8 DIN digital panel meters, counters, timers, remote displays, and DIN-rail transmitters, as explained in the Instrument Setup Software Manual. Laureate 1/8 DIN instruments can also be set up from the front panel, as explained in their respective Owners Manuals. Instrument Setup software is of benefit whether or not the PC is connected to the instrument.

  • When the PC is connected to the instrument, Instrument Setup software can retrieve the setup file from the instrument or open a default setup file or previously saved setup file from disk View Setup, then provides graphical user interface (GUI) screens with pull-down menus applicable to input, display, scaling, filtering, alarms, communications, analog output, and front panel lockouts. Fields that are not applicable to the instrument as configured are either left out or grayed out. Clicking on any item will bring up a detailed Help screen for that item. After editing, the setup file can be downloaded, uploaded to the instrument, or saved to a disk. The same setup file can then be downloaded into multiple instruments.
  • When the PC is not connected to the instrument, the above GUI screens can be used to set up a virtual instrument. The setup file can then be saved to disk. Switching toView Menu then brings up a screen with the required front panel programming steps. This view can be printed out for use at the instrument site and to serve as a hard copy record.

    Download Free Instrument Setup Software


Installation

Set User Account Control (UAC) of MS Windows to "Never notifiy me" so that Instrument Setup Software can create directories. The UAC change screen can be reached as follows:

  • Under Windows 7, click on the Windows Start button in the lower left of the desktop and enter "UAC" in the search field.
  • Under Windows 8, navigate to Control Panel, then to the "User Accounts and Family Safety" section, and click on "Change User Account Control Settings."
  • Under Windows 10, click on the Windows Start button in the lower left of the desktop, then on "Settings", and enter "UAC" in the search field.
  • Reboot your computer for the changed UAC setting to take effect.
Meter board with USB Type-B connector

RJ11-to-DB9 cable with rear view of DB9 connector to PC

Laurel USB cable, P/N CBL05

RS232 cable, meter to PC, P/N CBL01

Laureate 1/8 DIN Laureate instruments must be equipped with a serial communications board and be connected to the computer via a serial communications cable. The connection can be via RS232, RS485, USB or Ethernet. Following setup, the serial communications board may be removed from the instrument if desired. The wiring of the RS232 cable is illustrated above with end views of the two connectors.

Laureate LT Series transmitters come standard with a 3-wire serial interface, which can be jumpered for RS232 or RS485.
Laureate LTE Series transmitters come standard with an Ethernet interface.

Meter Setup Screens

Click on any of the reduced screens below for a full-size screen view, then click on the Back button of your browser to return to this page. The screens examples below are for a fully-loaded Series 2 Digital Panel Meter (DPM), which is connected to the PC via RS232. If the meter is a Series 1 meter (pre-2007), this is sensed by the software, and somewhat different screens are brought up. Please see Series 1 setup screens.

Laurel Dual Channel Pulse Input Rate Meter
Welcome Screen
From the computer desktop, click on Start > Programs > IS2 > IS2. Or click on the IS icon on your desktop. This splash screen will be displayed for three seconds. The software revision number is in the lower right.
more
Setup Screen 02s for Digital Panel Meters and Digital Transmitters
Communications Selection Screen
Specify your desired communication protocol and the serial communications bus type, which should match the jumper setup of the instrument. Select None if the PC is not connected to the instrument.
more
Setup Screen 3 for Digital Panel Meters and Digital Transmitters
Establish Communications Screen
If you selected RS-232, you will be asked to specify the PC Com Port and Baud Rate, which should match the jumper setup of the instrument. Click on Establish. With the right settings, the Communications Established field will light up in green, and the Meter Type will be recognized. If so, click onMain Menu.
more
Setup Screen 4 for Digital Panel Meters and Digital Transmitters
Main Menu Screen
Click on File > Default Setup to retrieve the default setup file from disk for your type of meter. Click on File > Open Setupto retrieve a previously saved setup file from disk or on File > Save Setup to save your edited setup file to disk. Click onDPM > Get Setup to retrieve the setup file from your meter or on DPM > Put Setup to download your edited setup file into the meter.
more
Setup Screen 5 for Digital Panel Meters and Digital Transmitters
DPM Input + Display Setup Screen
From the Main Menu, click on View > Setup, then on theInput+Display tab. You can now specify the meter hardware, signal type, display mode, and functions of control inputs A and B. Clicking on any item brings up a pull-down menu with the available choices.
more
Setup Screen 6 for Digital Panel Meters and Digital Transmitters
DPM Scaling Setup Screen
Click on the Scaling tab, which provides three scaling methods to relate the signal to the displayed reading: 1) Scale and Offset method, 2) Coordinates of two points method, and 3) Reading Coordinates of Two Points method. The last method uses actual high and low signals, and the computer will prompt you.
more
Setup Screen 7 for Digital Panel Meters and Digital Transmitters
DPM Filter Setup Screen
Click on the Filter tab, which allows you to specify the digital filter time constant (if any), the adaptive filter threshold, and whether Peak / Valley values are filtered or unfiltered. As for all setup screens, clicking on the F1 key while an item is highlighted brings up a Help screen for that item, as illustrated.
more
Setup Screen 8 for Digital Panel Meters and Digital Transmitters
DPM Relay Alarms Setup Screen
Click on the Relay Alarms tab, which allows you to set up Alarms 1 and 2 for the optional dual relay output board. Clicking on any of the four numeric fields changes these to green and brings up a special field to enter the desired numeric value, which is tied to the displayed reading.
more
Setup Screen 9 for Digital Panel Meters and Digital Transmitters
DPM Communications Setup Screen
Click on the Communications tab so set up serial communications. In particular, you can special the Serial Protocol and the meter address if multiple meters are to be addressed on the same serial data line.
more
Setup Screen 10 for Digital Panel Meters and Digital Transmitters
DPM Analog Output Setup Screen
Click on the Analog Out tab so set up the optional analog output board. Three output ranges are selectable, the endpoints of which can be tied to user-specified High and Low readings.
more
Setup Screen 11 for Digital Panel Meters and Digital Transmitters
DPM Lockouts Setup Screen
Click on the Lockouts tab to check off menu items which will no longer be accessible from the front panel of the meter. This will simplify meter operation and prevent unintended setup changes.
more

Meter Setup Utilities

Setup Screen 12 for Digital Panel Meters and Digital Transmitters
DPM Front Panel Setup Screen
As an aid to programming the meter from the front panel when a serial connection is not available, you can return to the Main Menu and click on View > Menu. The required sequence of front panel screens will then be displayed. Click on any step in the sequence for the meaning of each digit, as illustrated for the FILtEr step. For a hardcopy, simply press on Print.
more
Setup Screen 13 for Digital Panel Meters and Digital Transmitters
DPM Jumper Setup Screen
Specify your desired communication protocol and the serial communications bus type, which should match the jumper setup of the instrument. Select None if the PC is not connected to the instrument.
more
Setup Screen 14 for Digital Panel Meters and Digital Transmitters
DPM Jumper Setup Screens
Click on any of the displayed plug-in boards, and you will be presented with the jumper positions and electrical connections for your selected board. This minimizes the need to refer to the printed manual.
more
Setup Screen 15 for Digital Panel Meters and Digital Transmitters
DPM Commands Screen
This page allows you set up external input, serial communications, an analog output proportional to the display (optional), and lockouts for Laureate digital counters. The grayed out area at the top right of the screen applies to Laureate remote displays.
more
Graphical Output Screens (not available with Ethernet)

From the Main Menu, click on Readings if your PC is connected to the meter. A pull-down menu then offers three choices: ListPlot and Graph.

  • List presents the latest readings in a 20-row by 10-column table. Press Pause at any time to freeze the display. This is one method to capture peak readings.   
  • Plot generates a plot of readings vs. time in seconds. It effectively turns the DPM-PC combination into a printing digital oscilloscope.
    more 
  • Graph generates a histogram where the horizontal axis is the reading and the vertical axis is the number of occurrences of readings. The display continually resizes itself as the number of readings increases.
    more
Setup Screen 18 for Digital Panel Meters and Digital Transmitters
DPM Calibration Screens
Click on the Scaling tab, which provides three scalClick on the Scaling tab, which provides three scaling methods to relate the signal to the displayed reading: 1) Scale and Offset method, 2) Coordinates of two points method, and 3) Reading Coordinates of Two Points method. The last method uses actual high and low signals, and the computer will prompt you.
more
Setup Screen 19 for Digital Panel Meters and Digital Transmitters
Frequency Meter Calibration Screen
Calibration of the quartz crystal of the Laureate frequency meter requires the input of a known frequency from a calibrator. Apply the frequency, then enter the frequency in Hertz. Calibration will be automatic, with storage of the calibration factor stored in non-volatile memory.
more

 

Laureate™ 1/8 DIN Case For Laureate Digital Panel Meters, Counters, Timers & Remote Displays

Laurel panel meter case

Key Features

  • Meets 1/8 DIN Standard.
  • Installs from front of panel.
  • Short depth behind the panel: only 4" (102 mm) plus connectors.
  • Understated 0.157" (4 mm) thick bezel.
  • Meets NEMA 4X (IP-65) for high-pressure wawshdon when panel mounted.
  • Screw clamps connectors meet VDE / IEC / UL / CSA safety standards.
  • Rugged GE Lexan® housing material.
  • Safety certified per EN 61010-1.
CE CertifiedRoHs CertifiedETL Certified

Dimensions

Mechanical specifications of Laureate digital panel meters and electronic counters

Maximum panel thickness: 4.5 mm (0.18")
Weight of base meter:
210 g (7.4 oz) typical (DPM, counter, timer, 6-digit remote display)
Weight of option boards: 30 g (1.0 oz) typical per board (analog output, relay output, communications)
Tightening Torque - Connectors: Screw terminal connectors: 5 lb-in (0.56 Nm)
Tightening Torque - Pawls: Digital Panel Meter Case Pawls: 5 lb-in (0.56 Nm)
Dimensioned CAD assembly drawings in EPRT, STEP, x_t. dwg, pdf file formats: Laureate-meter-case.zip (zipping prevents browser from opening CAD files as text files).

Panel Mounting

Mechanical Panel Mounting GuideSlide the meter into a 45 x 92 mm 1/8 DIN panel cutout. Ensure that the provided gasket is in place between the front of the panel and the back of the meter bezel. The meter is secured by two pawls, each held by a screw, as illustrated. Turning each screw counterclockwise extends the pawl outward from the case and behind the panel. Turning each screw clockwise further tightens it against the panel to secure the meter.

Turning each screw counterclockwise loosens the pawl and retracts it into its well. This position allows installed meter to be removed from their panel, or new meters to be installed in a panel. Do not remove the screws from their pawls. Doing so would cause the screw and pawl to fall off and likely get lost. Do not overtighten so as not to damage the plastic parts.

 

Optimizing Meter Inputs for Phase Angle & Power Factor Measurement

Phase angle and power factor measurement with the Laureate™ Phase Angle & Power Factor Meter require that two signals of identical periods be applied to Channels A and B. For best accuracy, both signals should have the same amplitude, the signal amplitude should be larger than 1V, and the trigger level should be minimized by selecting the ±12 mV jumper position.

The meter times zero crossings to 0.1 µs resolution over a user-selectable gate time from 10 ms to 199.99 s. By selecting the minimum gate time of 10 ms, the meter update rate will be approximately 20/s for 50/60 Hz AC line frequency. Improved accuracy will be obtained by making the gate time long enough so that multiple cycles are averaged.

Both signals applied to the meter should be mutually isolated by transformer coupling, so that they can then share the same ground in the meter. The current signal is typically obtained from a current transformer (CT). This should ideally be a CT with a voltage output or a current output in the mA range, which can then be converted to a voltage higher than 1V across an external dropping resistor without excessive heat generation.

Using Laureate Meters and Counters to Synchronize Motor Generators
Using Laurel Meters and Counters to Synchronize Two Motor Generators

Synchronization of two motor generators requires that the two frequencies be identical, that the lines be in phase, and that the line voltages be close to each other. In this illustration, a single Laureate dual channel counter measures both frequencies to six-figure accuracy in a few line cycles. Another Laureate dual channel counter measures phase angle to 0.1° resolution. Two Laureate AC RMS Voltmeters, which offer ranges of 200.00 V and 600.0 V, are used to display the two RMS voltages to 0.1% accuracy.

 

 

CAL-Digital

Certificate of Calibration

$65.00

DLS-XLOG2

XLog2 Data logging Software

$495.00

IPC

Splashproof Cover

$55.00

CON01

CON01 Connector

$75.00

CBL01

RS232 Cable for Meters

$35.00

CBL02

USB-to-RS232 Adapter Cable

$47.00

CBL04

RS232 Cable for LT Transmitters

$47.00

CBL05

USB Data Cable for Meters

$47.00

CBL06

USB-to-RS485 Adapter Cable

$47.00

CBL07

USB Programming & Data Cable

$47.00

CBL08

RS485 Splitter Cable

$33.00

CBL6

6-foot Power Cable

$41.00

CBL12

12-foot Power Cable

$47.00

Modular Design for Maximum Flexibility at Minimum Cost

All boards are isolated from meter and power grounds. Optional Plug-in-Play boards for communications and control include Ethernet, WiFi, serial communication boardsdual or quad relay boards, and an analog output board. Laureates may be powered from 85-264 Vac or optionally from 12-32 Vac or 10-48 Vdc. The display is available with bright red or green 0.56" (14.2mm) high LED digits. The 1/8 DIN case meets NEMA 4X (IP65) specifications from the front when panel mounted. Any setup functions and front panel keys can be locked out for simplified usage and security. A built-in 5, 10, 12, or 24 Vdc excitation supply can power transducers, eliminating the need for an external power supply. All power and signal connections are via UL / VDE / CSA rated screw clamp plugs.

The Laureate™ Series features modular design with up to 7 isolated plug-in boards, applicable to all Laureate 1/8 DIN Panel Meters.

Schematic for Digital Panel Meter

Modular Hardware

The design of the Laureate™ Series is modular for maximum flexibility at minimum cost. All boards are isolated from meter and power grounds. The base configuration for panel meters or counter consists of a main module (with computer and plug-in display boards), a power supply board, and a signal conditioner board. Optional plug-in-play boards include an isolated setpoint controller board, an isolated analog output board, and an isolated digital interface board. Modular design and a choice of plug-in options allow the Laureate to be customized for a broad range of applications from simple monitoring to control and computer interface. There can be up to five plug-in boards in a 1/8 DIN Laureate.

Dual Board sets

Connecting Laureate Panel Meters to a Local Area Network (LAN)

Up to 30 Laureate Panel Meters and/or LT Transmitters can be configured for RS485 and daisy-chained to an LT Transmitter using Laurel’s High Speed Ethernet-to-RS485 converter board for seamless LAN integration. Alternatively, Laurel LTE series Ethernet transmitters can connect directly to a LAN via an Ethernet cable. Setup for both configurations is streamlined using Laurel’s free Instrument Setup Software, which simplifies node discovery and transmitter configuration.

Flexible Communication Options for Panel Meters

Laureate Panel Meters can be equipped with Laurel communication boards to support various interfaces and protocols. These include serial interfaces with ASCII or Modbus RTU protocols, and Ethernet interfaces with web access, ASCII, or Modbus TCP/IP protocols, ensuring versatile connectivity for your commercial applications.

Laurel network with Ethernet-to-analog converter board

Ordering Guide
Part Number as Configured: L7020DFR
Price as Configured: $629.00

Click on the Option Board Links for More Product Information

Base Item
$169.00
Display Color
$41.00
$41.00
Power (Isolated) $75.00
$115.00
Relay Output (Isolated)
$0.00
$101.00
$70.00
$128.00
$96.00
Analog Output (Isolated)
$0.00
$115.00
$172.00
Data Interface (Isolated)
$0.00
$81.00
$109.00
$135.00
$81.00
$135.00
$237.00
$259.00
$182.00
$204.00
$171.00
$193.00
$204.00
$226.00
Signal Input (Isolated)
$81.00
Part Number as Configured:
L7020DFR
Price as Configured:
$629.00
Quantity:
- +
Extended Price:
$629.00

Understanding the Laureate™ 1/8 DIN Panel Meters for AC Phase Angle & AC Power Factor

The Laureate™ 1/8 DIN Panel Meters for phase angle and power factor computes phase angle θ by timing zero crossings of two signals applied to Channels A and B, to 0.1 µs resolution over a user-selectable gate time from 10 ms to 199.99 s. The phase angle range is selectable as 0° to 360° or -180° to +180°, with resolution selectable as 1°, 0.1°, or 0.01° and accuracy of 0.05° at 50 or 60 Hz. Maximum timing interval is 200 seconds.

Power Factor Computation

Power factor is the ratio of real power to apparent power — for sinusoidal signals differing by phase angle θ, power factor is cos(θ). The meter computes this from the measured phase angle, with readings from 1.000 to 0.000 at three decimal places and 0.1% accuracy for sinusoidal signals at 50/60 Hz. While power factor is always physically positive, the meter artificially assigns a minus sign for negative phase angles, and sets power factor to 0 for phase angles greater than 90°.

Optimizing Meter Inputs

Phase angle and power factor measurement require two signals of identical period applied to Channels A and B. For best accuracy, both signals should have the same amplitude, amplitude should exceed 1V, and trigger level should be minimized by selecting the ±12 mV jumper position. At the minimum 10 ms gate time, update rate is approximately 20/s at 50/60 Hz line frequency; improved accuracy comes from a gate time long enough to average multiple cycles. Both signals should be mutually isolated by transformer coupling so they can share the same ground in the meter — the current signal is typically obtained from a current transformer, ideally one with voltage output or a mA-range current output converted to above 1V across an external dropping resistor without excessive heat generation.

Synchronizing Motor Generators

Synchronization of two motor generators requires identical frequencies, in-phase lines, and close line voltages. A single Laureate dual-channel counter measures both frequencies to six-figure accuracy in a few line cycles; another Laureate dual-channel counter measures phase angle to 0.1° resolution; and two Laureate AC RMS Voltmeters (200.00V and 600.0V ranges) display the two RMS voltages to 0.1% accuracy — together confirming all three conditions before paralleling.

Extended DPM Capability

Custom curve linearization is achievable with up to 180 data points input into a spreadsheet or text file, with spline-fit segments downloaded to the meter via RS232.

Factory-Calibrated Accuracy

All signal conditioner board ranges are factory-calibrated, with calibration factors stored in EEPROM. Field replacement of the signal conditioner board doesn't require recalibrating the meter. Factory recalibration is recommended annually.

Where Phase Angle & Power Factor Panel Meters Are Used

  • Power Factor Correction & Capacitor Bank Control — real-time phase angle/PF display driving automatic capacitor switching decisions.
  • Generator Synchronization & Paralleling — phase, frequency, and voltage matching before connecting a generator to a bus or grid.
  • Motor & VFD Diagnostics — phase relationship monitoring between voltage and current for load characterization.
  • Utility Billing & Penalty Avoidance — continuous PF monitoring to flag conditions that would trigger low-power-factor utility penalties.
  • Substation & Switchgear Instrumentation — phase angle readout supporting protective relaying and power quality studies.
  • Renewable Energy Inverter Testing — verifying inverter output phase relationship to the grid for interconnection compliance.
  • Laboratory & R&D Test Benches — precise phase and PF measurement for component and system characterization.

Phase Angle & Power Factor Panel Meter Frequently Asked Questions

Why does it matter that both input signals have the same amplitude, not just the same period?

The meter times zero crossings to determine phase angle, and signal amplitude affects how cleanly and consistently a zero crossing can be detected relative to noise and the trigger threshold — documented guidance specifically recommends matched amplitude between the two signals as a best practice for accuracy, since mismatched amplitudes can make zero-crossing detection timing less consistent between the two channels even though the underlying phase relationship itself doesn't depend on amplitude.

Why is a dropping resistor's heat generation specifically called out as a concern when converting a CT's current output to a voltage?

A CT with mA-range current output needs to be converted to a voltage above 1V for the meter's input, typically via a resistor that develops that voltage from the CT's current — documented guidance specifically flags avoiding "excessive heat generation" in that resistor, meaning the resistor's power rating needs to be selected appropriately for the CT's current and the desired voltage drop, since an undersized resistor could overheat under continuous operation.

What's the practical tradeoff between the 10 ms minimum gate time and using a longer gate time?

At the minimum 10 ms gate time, the meter documents an update rate of approximately 20 readings/second at line frequency — fast, but based on relatively few signal cycles per reading. A longer gate time averages more cycles per reading, documented as improving accuracy, but at the cost of a slower update rate — the right choice depends on whether an application prioritizes fast response or maximum measurement precision.

Why does the meter force power factor to display 0 once phase angle exceeds 90°, rather than showing a small negative or continuing value?

Since power factor for sinusoidal signals is mathematically cos(θ), and cos(θ) genuinely does continue changing beyond 90°, this is a documented, deliberate display convention rather than a mathematical necessity — displaying 0 beyond 90° phase angle keeps the power factor reading within its conventional, practically meaningful range rather than showing values that wouldn't correspond to a real-world power factor interpretation in typical applications.

Does selecting the 0° to 360° phase angle range versus the -180° to +180° range change the underlying measurement accuracy?

These are documented as two selectable display range options for representing the same underlying measured phase relationship — the choice affects how the result is presented (unsigned 0-360° versus signed ±180°) rather than changing the meter's actual measurement technique or accuracy, so the choice can be made based on which convention is more intuitive or standard for the specific application.

Why does the motor generator synchronization application need three separate instruments instead of one meter reading everything?

Each of the three conditions for safe synchronization — matched frequency, matched phase, and matched voltage — is documented as requiring its own dedicated measurement: a dual-channel counter for six-figure frequency accuracy, a separate dual-channel counter configured for phase angle, and two separate AC RMS voltmeters for the two line voltages. Combining all three measurement types with their differing precision needs into a single instrument isn't how this documented application is structured.

What does the "time before zero out" setting actually do, and how is it different from gate time?

Gate time controls the timing window used to compute each phase angle or power factor reading, while "time before zero out" is documented as a separate, independently selectable setting (10 ms to 199.99 s) specifically used to indicate loss of signal — if no valid signal is detected within that configured window, the meter zeroes out its reading rather than continuing to display a stale or invalid last measurement.

Is the 200-second maximum timing interval a hard limit on how slow a signal frequency the meter can measure phase angle on?

The 200-second maximum timing interval is documented as an upper bound on the measurement window itself — since the meter's frequency range extends down to 0.005 Hz (a period of 200 seconds), this maximum timing interval lines up directly with accommodating the lowest rated frequency, rather than being an arbitrary separate constraint.

Can custom curve linearization be applied to a phase angle or power factor reading, or is it only documented for flow applications?

The Extended DPM's custom curve linearization capability is documented generally, with flow meter linearization given as the example application — the underlying 180-point spline-fit technique is a general-purpose capability of the Extended counter board rather than one restricted specifically to flow signals, though the flow example is what's explicitly documented for this particular page.

Why does the ±12 mV jumper position specifically matter for minimizing trigger level?

A lower trigger threshold lets the meter detect a signal's zero crossing closer to the true zero-voltage point rather than waiting for the signal to rise further above it — documented guidance specifically recommends selecting the ±12 mV jumper position to minimize this trigger level, since a smaller trigger threshold reduces the timing offset introduced between the signal's actual zero crossing and the point the meter registers as the crossing, directly supporting the meter's stated phase angle accuracy.

Automatic Power Factor Correction & Capacitor Bank Switching Questions From the Field

What target power factor do automatic capacitor bank controllers typically aim for, and why not exactly 1.000?

Documented industry practice specifies a typical target power factor between 0.95 and 0.98 (sometimes stated as 0.98-0.99), rather than a perfect 1.000 — targeting slightly below unity provides margin against overcorrection, since actively over-compensating reactive power (a leading power factor from excess capacitance) can itself create problems, and utility penalty thresholds are usually satisfied well below perfect unity.

How does an APFC controller actually decide how many capacitor stages to switch in, rather than switching the entire bank at once?

Documented controller logic specifically computes the reactive power (kVAR) needed to close the gap between measured and target power factor, then selects the appropriate number and size of capacitor stages to supply roughly that amount — since motor and facility loads vary over time, documented guidance specifically warns against continuously using full capacitor bank capacity, favoring staged capacitor banks that can be switched incrementally to match actual, varying reactive power demand.

Why do APFC systems typically include a time delay before switching capacitor stages, rather than reacting instantly to every power factor change?

Documented controller design specifically incorporates switching delays to prevent excessive switching operations and extend contactor and capacitor equipment life — reacting instantly to every small, possibly transient fluctuation in measured power factor would cause frequent unnecessary switching, so a deliberate delay filters out short-term noise and lets the controller respond to genuinely sustained changes in reactive power demand.

What's the documented risk of using capacitor bank switching steps that are too large?

Documented guidance specifically warns that excessively large switching steps can cause frequent switching and power factor overshoot — swinging past the target power factor in the other direction (from lagging toward excessively leading) with each large switching event, which is why moderate step sizes (a documented example cites 20-50 kVAR steps for typical mixed industrial loads) are recommended over very large, coarse steps.

Does "rotational switching" in capacitor bank control serve a purpose beyond simply picking which stage to activate?

Yes — documented controller design specifically describes rotational switching as a strategy that distributes switching operations evenly across all available capacitor contactors and stages over time, rather than repeatedly cycling the same stage — this specifically extends the working life of each individual contactor and capacitor by avoiding uneven wear concentrated on whichever stage happens to be switched first or most often.

Can a fixed capacitor value be combined with an automatically-switched capacitor bank in the same installation?

Yes — documented controller capability specifically allows a fixed capacitor value to be added to the measured, automatically-switched capacitor power as a baseline — this is documented as useful specifically for compensating the reactive power drawn by a transformer itself, which is a relatively constant reactive load that doesn't need dynamic, automatically-switched correction the way variable motor loads do.

Does an automatic power factor controller need both current and voltage measurement, or is current alone sufficient to determine power factor?

Both are documented as necessary — an APFC controller is specifically described as continuously monitoring the reactive and real vectors of current in both the current and voltage measurement paths, since power factor is fundamentally a relationship between voltage and current phase, not a property derivable from either signal in isolation.

Is dynamic (real-time, load-following) power factor correction actually worth the added control complexity compared to a simpler fixed-capacitor installation?

Documented economic analysis of a dynamic capacitor bank control system found genuine payback within a documented timeframe (a specific case study cited roughly 4 years and 4 months) through reduced energy losses and improved system efficiency — suggesting that for facilities with genuinely variable, time-dependent reactive power demand, dynamic correction can be economically justified rather than purely a technical refinement over simpler fixed compensation.