Panel Meters for Duty Cycle and Pulse Width Modulation (PWM) Applications P/N L8101EFR

Panel Meters for Duty Cycle and Pulse Width Modulation (PWM) Applications

Price: $725.00
  • P/NL8101EFR
- +

Features

  • Displays Duty Cycle with resolution of 1% , 0.1%  or 0.01% .
  • Displays Pulse Width Modulation (PWM) in engineering units
  • Frequencies from 0.005 Hz to 10 kHz.
  • Inputs from NPN or PNP proximity switches, contact closures, digital logic, magnetic pickups down to 12 mV, or AC inputs up to 250 Vac.
  • Takes ratio of ON or OFF period and total period.
  • Triggers on positive or negative pulse edges.
  • Digital span adjust from 0 to ±999,999, zero adjust from -999,999 to +999,999
  • Front panel scalable: to ±999,999 for use with current shunts
  • 1/8 DIN size with bright red or green 0.56" (14.2mm), high LED digits
  • Transducer excitation output, 5, 10, 12, or 24 Vdc (isolated)
  • Power 85-264 Vac / 90-300 Vdc or 10-48 Vdc / 12-32 Vac (isolated)
  • Operating temperature from -40°C to 70°C  (-40°F to 158°F)
  • Wide choice of Plug-in-Play options:
    - 2 or 4 relays, mechanical or solid state, for alarm or control (isolated)
    - 1 or 2 Analog output, 4-20 mA, 0-20 mA, 0-10V, or -10V to +10V (isolated)
    - Communications: Ethernet, WiFi, USB, RS232, RS485 (isolated)

Clock diagram, 4-20 mA duty cycle transmitter

The Laureate™ 1/8 DIN Panel Meters for duty cycle

is a measure of ON or OFF period as a percentage of total period. Duty cycle is determined by averaging an integral number of periods over a gate time which is selectable from 10 ms to 199.99 s. The same signal is applied to Channels A and B. The panel meters divide the average pulse width t by the period P between pulses and expresses the ratio t/P in percent. A resolution of 1%, 0.1%  or 0.01%  is selectable. By selecting leading or falling pulse edges, ON or OFF duty cycle can be displayed.

Pulse Width Modulation (PWM) is a transducer output format where the measured information is provided as duty cycle applied to a constant frequency, such as 120 Hz. As for duty cycle, the panel meters divide the average pulse width by the period between pulses over a gate time which is selectable from 10 ms to 199.99 s. It then scales this ratio mathematically to display this ratio in engineering units, such as relative humidity (RH).

The Laureate duty cycle & pulse width modulation meter uses an Extended counter main board and the FR dual-channel signal conditioner board, which accepts signals from 12 mV to 250 Vac, inputs from proximity switches with a PNP or NPN output, TTL or CMOS logic, and contact closures. Jumper selections provide optimum operation for different sensor types and noise conditions. A built-in (isolated) 5, 10, 12, or 24 Vdc excitation supply can power proximity switches and other sensors.

Extended DPM makes this counter also suitable for A-B time interval, stopwatch, frequency, rate, period, square root of rate, up or down total, arithmetic functions, simultaneous rate and total, phase angle, batching, and custom curve linearization.

Laureate Panel Meters are easily programmed with Laurel’s free Instrument Setup Software, downloadable from our website and compatible with Windows PCs, requiring a data interface board for setup.

All signal conditioner board ranges are factory-calibrated, with calibration factors for each range securely stored in an onboard EEPROM. These factors can be scaled via software to accommodate external shunts, enabling field replacement of signal conditioner boards without necessitating recalibration of the associated panel meters. For optimal accuracy, factory recalibration is recommended annually. All Laurel Electronics instruments undergo factory calibration using the industry-leading Fluke calibrators, which are recalibrated yearly and certified traceable to national standards, ensuring the highest level of precision and reliability.

Digital signal filtering modes can be selected to ensure stable readings in electrically noisy environments.
  • An unfiltered selection provides true peak and valley readings and aids in control applications.
  • A batch average filter selection averages each 16 conversions.
  • An adaptive moving average filter selection provides a choice of 8 time constants from 80 ms to 9.6 seconds. When a significant change in signal level occurs, the filter adapts by briefly switching to the shortest time to follow the change, then reverts back to its selected time constant. An Auto setting selects the time constant selection based on signal noise.

Peak and valley values are automatically captured. These may be displayed via a front panel pushbutton command or control signal at the rear connector, or be transmitted as serial data.

Two rear panel control Inputs (CMOS/TTL levels, logic 0 = tied to digital ground, logic 1 = open) or dry contacts that can be set to control / activate 14 meter commands.

An (isolated) 5, 10, 12, or 24 Vdc excitation output is standard to power transducers or two-wire transmitters. Ratiometric operation, which automatically compensates for changes in the applied excitation, is jumper selectable for applications, such as bridges, where the signal to be measured is proportional to the excitation level.

Duty Cycle Measurement
Item Displayed ON or OFF duty cycle of periodic pulse waveshape
Display Units 1%, 0.1%, 0.01%
Frequency Range 0.005 Hz to 10 kHz
Accuracy 0.01%, 0.005 Hz to 500 Hz, 0.1% at 5 kHz, 1% at 10 kHz
Maximum Timing Interval 199.99 s
Pulse Width Modulation (PWM) Measurement
Item Displayed Measurement based on Pulse Width Modulation (PWM) input
Display Units Scaled reading in engineering units
Frequency Range 0.005 Hz to 10 kHz
Accuracy 0.01%, 0.005 Hz to 500 Hz, 0.1% at 5 kHz, 1% at 10 kHz
Maximum Timing Interval 199.99 s
Display
Readout 6 LED digits, 7-segment, 14.2 mm (.56"), red or green.
Range -999,999 to +999,999
Indicators Four LED lamps
Inputs
Types AC, pulses from NPN, PNP transistors, contact closures, magnetic pickups.
Signal Ground Common ground for channels A & B
Minimum Signal Nine ranges from (-12 to +12 mV) to (+1.25 to +2.1V).
Maximum Signal 250 Vac
Noise Filter 1 MHz, 30 kHz, 250 Hz (selectable)
Contact Debounce 0, 3, 50 ms (selectable)
Recalibration: All ranges are calibrated at the factory. Recalibration is recommended every 12 months.
Update Rate
Conversion Interval Gate time + 30 ms+ 0-2 signal periods
Gate Time Selectable 10 ms to 199.99 s
Time Before Zero Out Selectable 10 ms to 199.99 s
Excitation Output (standard)
5 Vdc 5 Vdc ± 5%, 100 mA (jumper selectable)
10 Vdc 10 Vdc ± 5%, 120 mA (jumper selectable)
12 Vdc 12 Vdc ± 5%, 100 mA (jumper selectable)
24 Vdc 24 Vdc ± 5%, 50 mA (jumper selectable)
Output Isolation 50 Vdc from signal ground
Power Supply Boards (one required)
Voltage, standard 85-264 Vac or 90-300 Vdc
Voltage, optional 12-32 Vac or 10-48 Vdc
Frequency DC or 47-63 Hz
Power  consumption (typical, base meter) 1.2W @ 120 Vac, 1.5W @ 240 Vac, 1.3W @ 10 Vdc, 1.4W @ 20 Vdc, 1.55W @ 30 Vdc, 1.8W @ 40 Vdc, 2.15W @ 48 Vdc
Power Isolation 250V rms working, 2.3 kV rms per 1 min test
Analog Output Boards (one optional)
Output levels 4-20 mA, 0-20 mA, 0-10V, -10 to +10V (jumper selectable)
Current compliance 2 mA at 10V ( > 5 kΩ load)
Voltage compliance 12V at 20 mA (< 600 Ω load)
Scaling Zero and full scale adjustable from -99999 to +99999
Resolution 16 bits (0.0015% of full scale)
Isolation 250V rms working, 2.3 kV rms per 1 min test
(dual analog outputs share the same ground)
Relay Output Boards (one optional)
Dual magnetic relays 2 Form C, 10A max, 440Vac or 125Vdc max, 2500VA or 300W
Quad magnetic relays 4 Form A (NO), 10A max, 440Vac or 125Vdc max, 2500VA or 300W
Dual solid state relays 2 Form A (NO), AC or DC, 0V - 400V, 120Ma, 35Ohms (max at On-State)
Quad solid state relays 4 Form A (NO), AC or DC, 0V - 400V, 120Ma, 35Ohms (max at On-State)
Relay commons Isolated commons for dual relays or each pair of quad relays
Relay isolation 250V rms working, 2.3 kV rms per 1 minute test
Relay latching modes Latching or non-latching
Relay active modes Active on or off, active high or low
Hysteresis modes QA passband mode, split hysteresis, span hysteresis
Communication Boards (one optional)
Board selections RS232RS485 with dual RJ11 connectors, RS485 with dual RJ45 connectors, USB, Ethernet, USB-to-RS485 gatewayEthernet-to-RS485 gateway, WiFi with built-in antenna plus USB & RS485, WiFi with external antenna plus USB & RS485
Protocols Laurel Custom ASCII (serial), Modbus RTU (serial), Modbus TCP (Ethernet or WiFi)
Digital addresses 247 (Modbus), 31 (Laurel ASCII),
Isolation 250V rms working, 2.3 kV rms per 1 min test
Environmental
Operating temperature -40°C to 70°C (-40°F to 158°F)
Storage temperature. -40°C to 85°C (-40°F to 185°F)
Relative humidity 95% at 40°C, non-condensing
Protection NEMA-4X (IP-65) when panel mounted
Signal Connections
Duty Cycle Flow Graph
Mechanical
Enclosure 1/8 DIN, high impact plastic, UL 94V-0, color: black
Mounting 1/8 DIN panel cutout required: 3.622" x 1.772" (92 mm x 45 mm).
Dimensions 4.68" x 2.45" x 5.64" (119 mm x 62 mm x 143 mm) (W x H x D)
Maximum panel thickness 4.5 mm (0.18")
Tightening Torque - Connectors Screw terminal connectors: 5 lb-in (0.56 Nm)
Tightening Torque - Pawls Digital Panel Meter Case Pawls: 5 lb-in (0.56 Nm)
Weight of base meter 210 g (7.4 oz) typical (DPM, counter, timer, 6-digit remote display)
Weight of option boards 30 g (1.0 oz) typical per board (analog output, relay output, communications)
General
Programming Methods Four front panel buttons or via Laurel's free Instrument Setup Software, which runs on a PC under MS Windows. 
Security Lockout options include using the front panel buttons, the free Instrument Setup Software, or a hardware jumper.
Warranty 3 years parts & labor
Recalibration: All ranges are calibrated at the factory. Recalibration is recommended every 12 months.

Free Instrument Setup Software for Series 2 Laureates

Digital Panel Meter Laurel Electronics Digital Transmitters
1/8 DIN Digital Panel Meters DIN Rail Transmitters

Free Downloadable Windows-based Instrument Setup (IS) software (Data Interface Board Required) for use with our programmable Digital Panel Meters, Scale Meters, Counters, Timers, Remote Displays, and Transmitters, are an easy method to set up Laureate 1/8 DIN digital panel meters, counters, timers, remote displays, and DIN-rail transmitters, as explained in the Instrument Setup Software Manual. Laureate 1/8 DIN instruments can also be set up from the front panel, as explained in their respective Owners Manuals. Instrument Setup software is of benefit whether or not the PC is connected to the instrument.

  • When the PC is connected to the instrument, Instrument Setup software can retrieve the setup file from the instrument or open a default setup file or previously saved setup file from disk View Setup, then provides graphical user interface (GUI) screens with pull-down menus applicable to input, display, scaling, filtering, alarms, communications, analog output, and front panel lockouts. Fields that are not applicable to the instrument as configured are either left out or grayed out. Clicking on any item will bring up a detailed Help screen for that item. After editing, the setup file can be downloaded, uploaded to the instrument, or saved to a disk. The same setup file can then be downloaded into multiple instruments.
  • When the PC is not connected to the instrument, the above GUI screens can be used to set up a virtual instrument. The setup file can then be saved to disk. Switching toView Menu then brings up a screen with the required front panel programming steps. This view can be printed out for use at the instrument site and to serve as a hard copy record.

    Download Free Instrument Setup Software


Installation

Set User Account Control (UAC) of MS Windows to "Never notifiy me" so that Instrument Setup Software can create directories. The UAC change screen can be reached as follows:

  • Under Windows 7, click on the Windows Start button in the lower left of the desktop and enter "UAC" in the search field.
  • Under Windows 8, navigate to Control Panel, then to the "User Accounts and Family Safety" section, and click on "Change User Account Control Settings."
  • Under Windows 10, click on the Windows Start button in the lower left of the desktop, then on "Settings", and enter "UAC" in the search field.
  • Reboot your computer for the changed UAC setting to take effect.
Meter board with USB Type-B connector

RJ11-to-DB9 cable with rear view of DB9 connector to PC

Laurel USB cable, P/N CBL05

RS232 cable, meter to PC, P/N CBL01

Laureate 1/8 DIN Laureate instruments must be equipped with a serial communications board and be connected to the computer via a serial communications cable. The connection can be via RS232, RS485, USB or Ethernet. Following setup, the serial communications board may be removed from the instrument if desired. The wiring of the RS232 cable is illustrated above with end views of the two connectors.

Laureate LT Series transmitters come standard with a 3-wire serial interface, which can be jumpered for RS232 or RS485.
Laureate LTE Series transmitters come standard with an Ethernet interface.

Meter Setup Screens

Click on any of the reduced screens below for a full-size screen view, then click on the Back button of your browser to return to this page. The screens examples below are for a fully-loaded Series 2 Digital Panel Meter (DPM), which is connected to the PC via RS232. If the meter is a Series 1 meter (pre-2007), this is sensed by the software, and somewhat different screens are brought up. Please see Series 1 setup screens.

Laurel Dual Channel Pulse Input Rate Meter
Welcome Screen
From the computer desktop, click on Start > Programs > IS2 > IS2. Or click on the IS icon on your desktop. This splash screen will be displayed for three seconds. The software revision number is in the lower right.
more
Setup Screen 02s for Digital Panel Meters and Digital Transmitters
Communications Selection Screen
Specify your desired communication protocol and the serial communications bus type, which should match the jumper setup of the instrument. Select None if the PC is not connected to the instrument.
more
Setup Screen 3 for Digital Panel Meters and Digital Transmitters
Establish Communications Screen
If you selected RS-232, you will be asked to specify the PC Com Port and Baud Rate, which should match the jumper setup of the instrument. Click on Establish. With the right settings, the Communications Established field will light up in green, and the Meter Type will be recognized. If so, click onMain Menu.
more
Setup Screen 4 for Digital Panel Meters and Digital Transmitters
Main Menu Screen
Click on File > Default Setup to retrieve the default setup file from disk for your type of meter. Click on File > Open Setupto retrieve a previously saved setup file from disk or on File > Save Setup to save your edited setup file to disk. Click onDPM > Get Setup to retrieve the setup file from your meter or on DPM > Put Setup to download your edited setup file into the meter.
more
Setup Screen 5 for Digital Panel Meters and Digital Transmitters
DPM Input + Display Setup Screen
From the Main Menu, click on View > Setup, then on theInput+Display tab. You can now specify the meter hardware, signal type, display mode, and functions of control inputs A and B. Clicking on any item brings up a pull-down menu with the available choices.
more
Setup Screen 6 for Digital Panel Meters and Digital Transmitters
DPM Scaling Setup Screen
Click on the Scaling tab, which provides three scaling methods to relate the signal to the displayed reading: 1) Scale and Offset method, 2) Coordinates of two points method, and 3) Reading Coordinates of Two Points method. The last method uses actual high and low signals, and the computer will prompt you.
more
Setup Screen 7 for Digital Panel Meters and Digital Transmitters
DPM Filter Setup Screen
Click on the Filter tab, which allows you to specify the digital filter time constant (if any), the adaptive filter threshold, and whether Peak / Valley values are filtered or unfiltered. As for all setup screens, clicking on the F1 key while an item is highlighted brings up a Help screen for that item, as illustrated.
more
Setup Screen 8 for Digital Panel Meters and Digital Transmitters
DPM Relay Alarms Setup Screen
Click on the Relay Alarms tab, which allows you to set up Alarms 1 and 2 for the optional dual relay output board. Clicking on any of the four numeric fields changes these to green and brings up a special field to enter the desired numeric value, which is tied to the displayed reading.
more
Setup Screen 9 for Digital Panel Meters and Digital Transmitters
DPM Communications Setup Screen
Click on the Communications tab so set up serial communications. In particular, you can special the Serial Protocol and the meter address if multiple meters are to be addressed on the same serial data line.
more
Setup Screen 10 for Digital Panel Meters and Digital Transmitters
DPM Analog Output Setup Screen
Click on the Analog Out tab so set up the optional analog output board. Three output ranges are selectable, the endpoints of which can be tied to user-specified High and Low readings.
more
Setup Screen 11 for Digital Panel Meters and Digital Transmitters
DPM Lockouts Setup Screen
Click on the Lockouts tab to check off menu items which will no longer be accessible from the front panel of the meter. This will simplify meter operation and prevent unintended setup changes.
more

Meter Setup Utilities

Setup Screen 12 for Digital Panel Meters and Digital Transmitters
DPM Front Panel Setup Screen
As an aid to programming the meter from the front panel when a serial connection is not available, you can return to the Main Menu and click on View > Menu. The required sequence of front panel screens will then be displayed. Click on any step in the sequence for the meaning of each digit, as illustrated for the FILtEr step. For a hardcopy, simply press on Print.
more
Setup Screen 13 for Digital Panel Meters and Digital Transmitters
DPM Jumper Setup Screen
Specify your desired communication protocol and the serial communications bus type, which should match the jumper setup of the instrument. Select None if the PC is not connected to the instrument.
more
Setup Screen 14 for Digital Panel Meters and Digital Transmitters
DPM Jumper Setup Screens
Click on any of the displayed plug-in boards, and you will be presented with the jumper positions and electrical connections for your selected board. This minimizes the need to refer to the printed manual.
more
Setup Screen 15 for Digital Panel Meters and Digital Transmitters
DPM Commands Screen
This page allows you set up external input, serial communications, an analog output proportional to the display (optional), and lockouts for Laureate digital counters. The grayed out area at the top right of the screen applies to Laureate remote displays.
more
Graphical Output Screens (not available with Ethernet)

From the Main Menu, click on Readings if your PC is connected to the meter. A pull-down menu then offers three choices: ListPlot and Graph.

  • List presents the latest readings in a 20-row by 10-column table. Press Pause at any time to freeze the display. This is one method to capture peak readings.   
  • Plot generates a plot of readings vs. time in seconds. It effectively turns the DPM-PC combination into a printing digital oscilloscope.
    more 
  • Graph generates a histogram where the horizontal axis is the reading and the vertical axis is the number of occurrences of readings. The display continually resizes itself as the number of readings increases.
    more
Setup Screen 18 for Digital Panel Meters and Digital Transmitters
DPM Calibration Screens
Click on the Scaling tab, which provides three scalClick on the Scaling tab, which provides three scaling methods to relate the signal to the displayed reading: 1) Scale and Offset method, 2) Coordinates of two points method, and 3) Reading Coordinates of Two Points method. The last method uses actual high and low signals, and the computer will prompt you.
more
Setup Screen 19 for Digital Panel Meters and Digital Transmitters
Frequency Meter Calibration Screen
Calibration of the quartz crystal of the Laureate frequency meter requires the input of a known frequency from a calibrator. Apply the frequency, then enter the frequency in Hertz. Calibration will be automatic, with storage of the calibration factor stored in non-volatile memory.
more

 

Laureate™ 1/8 DIN Case For Laureate Digital Panel Meters, Counters, Timers & Remote Displays

Laurel panel meter case

Key Features

  • Meets 1/8 DIN Standard.
  • Installs from front of panel.
  • Short depth behind the panel: only 4" (102 mm) plus connectors.
  • Understated 0.157" (4 mm) thick bezel.
  • Meets NEMA 4X (IP-65) for high-pressure wawshdon when panel mounted.
  • Screw clamps connectors meet VDE / IEC / UL / CSA safety standards.
  • Rugged GE Lexan® housing material.
  • Safety certified per EN 61010-1.
CE CertifiedRoHs CertifiedETL Certified

Dimensions

Mechanical specifications of Laureate digital panel meters and electronic counters

Maximum panel thickness: 4.5 mm (0.18")
Weight of base meter:
210 g (7.4 oz) typical (DPM, counter, timer, 6-digit remote display)
Weight of option boards: 30 g (1.0 oz) typical per board (analog output, relay output, communications)
Tightening Torque - Connectors: Screw terminal connectors: 5 lb-in (0.56 Nm)
Tightening Torque - Pawls: Digital Panel Meter Case Pawls: 5 lb-in (0.56 Nm)
Dimensioned CAD assembly drawings in EPRT, STEP, x_t. dwg, pdf file formats: Laureate-meter-case.zip (zipping prevents browser from opening CAD files as text files).

Panel Mounting

Mechanical Panel Mounting GuideSlide the meter into a 45 x 92 mm 1/8 DIN panel cutout. Ensure that the provided gasket is in place between the front of the panel and the back of the meter bezel. The meter is secured by two pawls, each held by a screw, as illustrated. Turning each screw counterclockwise extends the pawl outward from the case and behind the panel. Turning each screw clockwise further tightens it against the panel to secure the meter.

Turning each screw counterclockwise loosens the pawl and retracts it into its well. This position allows installed meter to be removed from their panel, or new meters to be installed in a panel. Do not remove the screws from their pawls. Doing so would cause the screw and pawl to fall off and likely get lost. Do not overtighten so as not to damage the plastic parts.

 

Duty Cycle & Pulse Width Modulation (PWM) Modes
Duty cycle graphr In duty cycle mode, the meter displays ON or OFF time in percent from 0% to 100% of period for repetitive pulse trains. In the illustration, duty cycle in percent is 100 x t/P. In pulse width modulation (PWM) mode, the meter also determines the duty cycle ratio, but then scales this ratio for display in engineering units.
Monitoring Laser OperationPM and Speed
Duty cycle measurement Laureate counters can be programmed to display the duty cycle of a laser, the number of pulses, elapsed time, the number of pulses, the average pulse width in µs, and total energy applied. This data can be transmitted digitally via RS485 or Ethernet.

 

 

CAL-Digital

Certificate of Calibration

$65.00

DLS-XLOG2

XLog2 Data logging Software

$495.00

IPC

Splashproof Cover

$55.00

CON01

CON01 Connector

$75.00

CBL01

RS232 Cable for Meters

$35.00

CBL02

USB-to-RS232 Adapter Cable

$47.00

CBL04

RS232 Cable for LT Transmitters

$47.00

CBL05

USB Data Cable for Meters

$47.00

CBL06

USB-to-RS485 Adapter Cable

$47.00

CBL07

USB Programming & Data Cable

$47.00

CBL08

RS485 Splitter Cable

$33.00

CBL6

6-foot Power Cable

$41.00

CBL12

12-foot Power Cable

$47.00

Modular Design for Maximum Flexibility at Minimum Cost

All boards are isolated from meter and power grounds. Optional Plug-in-Play boards for communications and control include Ethernet, WiFi, serial communication boardsdual or quad relay boards, and an analog output board. Laureates may be powered from 85-264 Vac or optionally from 12-32 Vac or 10-48 Vdc. The display is available with bright red or green 0.56" (14.2mm) high LED digits. The 1/8 DIN case meets NEMA 4X (IP65) specifications from the front when panel mounted. Any setup functions and front panel keys can be locked out for simplified usage and security. A built-in 5, 10, 12, or 24 Vdc excitation supply can power transducers, eliminating the need for an external power supply. All power and signal connections are via UL / VDE / CSA rated screw clamp plugs.

The Laureate™ Series features modular design with up to 7 isolated plug-in boards, applicable to all Laureate 1/8 DIN Panel Meters.

Schematic for Digital Panel Meter

Modular Hardware

The design of the Laureate™ Series is modular for maximum flexibility at minimum cost. All boards are isolated from meter and power grounds. The base configuration for panel meters or counter consists of a main module (with computer and plug-in display boards), a power supply board, and a signal conditioner board. Optional plug-in-play boards include an isolated setpoint controller board, an isolated analog output board, and an isolated digital interface board. Modular design and a choice of plug-in options allow the Laureate to be customized for a broad range of applications from simple monitoring to control and computer interface. There can be up to five plug-in boards in a 1/8 DIN Laureate.

Dual Board sets

Connecting Laureate Panel Meters to a Local Area Network (LAN)

Up to 30 Laureate Panel Meters and/or LT Transmitters can be configured for RS485 and daisy-chained to an LT Transmitter using Laurel’s High Speed Ethernet-to-RS485 converter board for seamless LAN integration. Alternatively, Laurel LTE series Ethernet transmitters can connect directly to a LAN via an Ethernet cable. Setup for both configurations is streamlined using Laurel’s free Instrument Setup Software, which simplifies node discovery and transmitter configuration.

Flexible Communication Options for Panel Meters

Laureate Panel Meters can be equipped with Laurel communication boards to support various interfaces and protocols. These include serial interfaces with ASCII or Modbus RTU protocols, and Ethernet interfaces with web access, ASCII, or Modbus TCP/IP protocols, ensuring versatile connectivity for your commercial applications.

Laurel network with Ethernet-to-analog converter board

Ordering Guide
Part Number as Configured: L8101EFR
Price as Configured: $725.00

Click on the Option Board Links for More Product Information

Base Item
$169.00
Display Color
$41.00
$41.00
Power (Isolated) $75.00
$115.00
Relay Output (Isolated)
$0.00
$101.00
$70.00
$128.00
$96.00
Analog Output (Isolated)
$0.00
$115.00
$172.00
Data Interface (Isolated)
$0.00
$81.00
$109.00
$135.00
$81.00
$135.00
$237.00
$259.00
$182.00
$204.00
$171.00
$193.00
$204.00
$226.00
Signal Input (Isolated)
$81.00
Part Number as Configured:
L8101EFR
Price as Configured:
$725.00
Quantity:
- +
Extended Price:
$725.00

Understanding the Laureate™ 1/8 DIN Panel Meters for Duty Cycle and Pulse Width Modulation (PWM)

The Laureate™ 1/8 DIN Panel Meters for duty cycle measures ON or OFF period as a percentage of total period. Duty cycle is determined by averaging an integral number of periods over a gate time selectable from 10 ms to 199.99 s. The same signal is applied to Channels A and B — the meter divides the average pulse width t by the period P between pulses and expresses the ratio t/P in percent, with resolution of 1%, 0.1%, or 0.01% selectable. Selecting leading or falling pulse edges determines whether ON or OFF duty cycle is displayed.

Pulse Width Modulation (PWM) Mode

PWM is a transducer output format where measured information is provided as duty cycle applied to a constant frequency, such as 120 Hz. As with duty cycle mode, the meter divides average pulse width by the period between pulses over the same selectable gate time, then mathematically scales this ratio for display in engineering units, such as relative humidity (RH).

Accuracy and Range

Both duty cycle and PWM measurement operate over a frequency range of 0.005 Hz to 10 kHz, with accuracy of 0.01% from 0.005 Hz to 500 Hz, 0.1% at 5 kHz, and 1% at 10 kHz. Maximum timing interval is 199.99 s.

Signal Conditioning and Board Versatility

The meter uses an Extended counter main board and the FR dual-channel signal conditioner, accepting signals from 12 mV to 250 Vac. The same Extended board hardware is also suitable for A-B time interval, stopwatch, frequency, rate, period, square root of rate, up or down total, arithmetic functions, simultaneous rate and total, phase angle, batching, and custom curve linearization — duty cycle/PWM is one selectable operating mode among many on the same physical meter.

Monitoring Laser Operation

Laureate counters can be programmed to display the duty cycle of a laser, number of pulses, elapsed time, average pulse width in µs, and total energy applied — all from the same signal. This data can be transmitted digitally via RS485 or Ethernet.

Factory-Calibrated Accuracy

All signal conditioner board ranges are factory-calibrated, with calibration factors stored in EEPROM. Field replacement of the signal conditioner board doesn't require recalibrating the meter. Factory recalibration is recommended annually.

Where Duty Cycle & PWM Panel Meters Are Used

  • Humidity & Environmental Sensor Readout — displaying PWM-output transducer signals directly in relative humidity or other engineering units.
  • Laser Process Monitoring — duty cycle, pulse count, width, and total applied energy for pulsed laser systems.
  • Motor & Actuator Drive Verification — confirming actual delivered duty cycle against commanded PWM setpoints.
  • Heater & Proportional Control Verification — duty-cycle readout for time-proportioning heating or process control loops.
  • Power Supply & Converter Diagnostics — verifying switch-mode duty cycle in test and production environments.
  • Solenoid & Valve Duty Monitoring — ON-time percentage tracking for duty-rated actuators.
  • Renewable Energy Inverter Testing — PWM duty cycle verification for solar and wind power electronics.

Duty Cycle & PWM Panel Meter Frequently Asked Questions

Why does the meter apply the same signal to both Channels A and B for duty cycle measurement instead of using separate channels?

Duty cycle inherently requires comparing a pulse's active-time portion against its total period from the same single waveform — since both the pulse width and the overall period come from the identical signal, feeding it to both channels lets the meter's dual-channel processing derive both the numerator (pulse width t) and denominator (period P) of the t/P ratio from one physical connection rather than needing two separate signal sources.

What's the actual difference between "duty cycle mode" and "PWM mode" if both compute the same t/P ratio?

The underlying ratio calculation is documented as identical between the two modes — the distinction is what happens after that ratio is computed: duty cycle mode displays the raw percentage directly, while PWM mode takes that same ratio and mathematically scales it into different engineering units (such as relative humidity) appropriate for whatever physical quantity the transmitter is encoding via its PWM output.

Why would a PWM transducer use a fixed carrier frequency like 120 Hz instead of encoding information in the frequency itself?

Documented PWM transducer design specifically separates the carrier frequency (fixed, such as 120 Hz) from the information-carrying element (the duty cycle ratio) — keeping the frequency constant simplifies the receiving meter's job, since it only needs to track the changing ON/OFF ratio at a known, stable rate rather than simultaneously tracking a variable frequency and a variable duty cycle together.

Does selecting leading versus falling edge actually change the underlying measurement, or just which portion of the cycle is reported?

Just which portion is reported — since ON time and OFF time together make up the full period, selecting leading or falling pulse edges determines whether the meter reports the ON-time percentage or the OFF-time percentage of that same cycle; the underlying period and pulse timing being measured don't change, only which complementary percentage is calculated and displayed.

Why does accuracy degrade from 0.01% at low frequencies to 1% at 10 kHz, rather than staying constant across the full range?

This reflects the practical limits of timing resolution relative to signal period — at low frequencies, each cycle's period is long relative to the meter's underlying timing resolution, so the pulse-width-to-period ratio can be measured very precisely; at 10 kHz, each cycle is much shorter, leaving proportionally less time resolution available within each individual cycle to pin down the t/P ratio as precisely, which is why accuracy documented at 10 kHz is coarser than at low frequencies.

Can this same meter be reconfigured from duty cycle/PWM mode into, say, a stopwatch or frequency meter without buying new hardware?

Yes — the Extended counter main board is documented as supporting all of these modes (A-B time interval, stopwatch, frequency, rate, period, square root of rate, totalizing, arithmetic functions, phase angle, batching, custom curve linearization) on the same physical hardware; switching between them is a setup/configuration change via the front panel or setup software, not a hardware swap.

Does monitoring total energy applied in the laser application require a separate power meter, or does the Laureate counter compute it directly?

Documented capability specifically lists total energy applied as one of the parameters the Laureate counter itself can display, alongside duty cycle, pulse count, elapsed time, and average pulse width — this suggests the counter performs this calculation internally from the timing and pulse data it's already measuring, rather than requiring an entirely separate power/energy measurement instrument.

Can the laser monitoring data (duty cycle, pulse count, energy, etc.) be logged remotely, or does it require someone reading the front panel display?

It can be logged remotely — documented capability specifically states this data can be transmitted digitally via RS485 or Ethernet, meaning a connected data logger, SCADA system, or networked PC can capture and record these laser operating parameters continuously without requiring an operator to manually read and record the front panel display.

Does the meter's contact debounce and noise filter settings apply to duty cycle/PWM mode the same way they do in other counter modes?

Yes — since duty cycle and PWM measurement rely on the same underlying pulse-edge detection circuitry used across the Laureate counter's other modes, the selectable noise filter (1 MHz, 30 kHz, or 250 Hz) and contact debounce (0, 3, or 50 ms) settings apply here as well, letting the meter be tuned for a genuinely noisy PWM source (such as a long cable run picking up interference) the same way it would be tuned for a noisy frequency or rate signal.

Can the analog output board retransmit the measured duty cycle or PWM reading as a 4-20 mA or 0-10V signal to another system?

Yes — the optional analog output board is documented as available across the Laureate counter family generally, and since duty cycle/PWM is simply one of the meter's selectable operating modes on the same underlying hardware, the currently displayed duty cycle or scaled PWM reading can be retransmitted as 4-20 mA, 0-20 mA, or 0-10V for use by an external controller, recorder, or SCADA system, the same as it would for any other mode's reading.

PWM Frequency Selection: Audible Noise & Switching Loss Questions From the Field

Why does a motor driven by PWM sometimes produce an audible whine, and what does frequency have to do with it?

Documented analysis specifically explains that any PWM frequency within the human audible range (roughly 20 Hz to 20 kHz) causes the motor's windings and iron core to physically vibrate at that switching frequency, and that vibration transmits as audible noise — a common default PWM frequency like ~490 Hz sits squarely in this audible range, which is documented as a frequent source of unwanted motor whine in real designs.

If raising PWM frequency above the audible range eliminates motor whine, why not always default to a very high frequency?

Documented engineering tradeoffs specifically warn against this — switching losses in MOSFETs and similar switching devices increase roughly proportionally with frequency, meaning doubling the PWM frequency roughly doubles switching losses, which raises device temperature and can reduce overall system efficiency; a documented example shows a MOSFET temperature increase of about 15°C when frequency was raised from 20 kHz to 40 kHz specifically to eliminate noise.

Is there a documented "sweet spot" frequency range commonly recommended for DC motor PWM control?

Yes — documented guidance commonly cites roughly 15-20 kHz as a frequently chosen range for DC motor control, specifically because it sits above most of the audible range while avoiding the more severe switching losses associated with much higher frequencies; some sources note smaller motors or micro-actuators may benefit from even higher frequencies (above 10 kHz) given their different inductance characteristics.

Does LED PWM dimming face the same audible-noise concern as motor control, or is that specific to motors?

LEDs themselves are documented as facing a related but distinct audible noise mechanism — the noise in LED dimming applications is documented as originating from ripple current interacting with system components like output capacitors and power rails, particularly with large LED currents or multiple LED strings, rather than mechanical vibration of windings the way it occurs in motors, though the practical mitigation (shifting frequency above 20 kHz) is documented as a comparable solution.

Why is shifting PWM frequency above 20 kHz to eliminate audible noise sometimes described as "not always desirable" despite solving the noise problem?

Documented tradeoff analysis specifically identifies two consequences of this approach: increased switching losses (reducing system power efficiency) and greater electromagnetic interference (EMI) generation at higher switching frequencies — meaning eliminating audible noise this way can trade one engineering problem (acoustic noise) for others (thermal/efficiency and EMI compliance issues) that must be separately managed.

Does the minimum PWM frequency needed to avoid visible flicker in LED dimming applications differ meaningfully from the frequency needed to avoid audible motor noise?

Yes, documented guidance shows these are governed by different physical thresholds — visible flicker in LED dimming is documented as becoming perceptible below roughly 60-100 Hz depending on viewing conditions, with LED dimming commonly using 200 Hz to 2 kHz to comfortably clear that threshold, which is a substantially lower frequency range than the 15-20+ kHz commonly used specifically to avoid audible motor whine.

For a slow-responding load like a resistive heater, does PWM frequency selection face the same audible-noise/switching-loss tradeoff as motors and LEDs?

No, documented guidance specifically notes this case is different — because heaters respond slowly to power changes, even quite low PWM frequencies (documented as roughly 10-100 Hz) are sufficient to provide stable, effective temperature control, meaning heater PWM applications generally don't face the same pressure toward high frequencies that motor or LED audible-noise concerns create.

Does increasing PWM resolution (more duty-cycle steps) come with a tradeoff against frequency, or are they independent design choices?

They're documented as directly linked, not independent — since resolution is tied to how many discrete duty-cycle steps fit within one PWM period at a given underlying clock rate, documented guidance specifically notes that increasing resolution generally requires lowering the maximum achievable PWM frequency (or vice versa) for a fixed clock source, meaning a designer genuinely has to balance fine duty-cycle control against how high a frequency the system can practically achieve.