Panel Meters for Quadrature Encoder Input and Bidirectional Position or Rate Applications P/N L7101FQD

Panel Meters for Quadrature Encoder Input and Bidirectional Position or Rate Applications

Price: $789.00
  • P/NL7101FQD
- +

Features

  • Accepts low-level differential or single-ended 5V logic level signals from shaft encoders, linear encoders, incremental encoders or optical encoders
  • 6-digit scalable display for position, length or rate
  • Programmable for position, angle or rate
  • Maximum pulse rates of 250 kpulses/sec at X1, 125 kpulses/sec at X2, 62.5 kpulses/sec at X4
  • Display update rate up to 25/s
  • Zero channel input
  • Digital span adjust from 0 to ±999,999, zero adjust from -999,999 to +999,999
  • Front panel scalable: to ±999,999 for use with current shunts
  • 1/8 DIN size with bright red or green 0.56" (14.2mm), high LED digits
  • Transducer excitation output, 5, 10, 12, or 24 Vdc (isolated)
  • Power 85-264 Vac / 90-300 Vdc or 10-48 Vdc / 12-32 Vac (isolated)
  • Operating temperature from -40°C to 70°C  (-40°F to 158°F)
  • Wide choice of Plug-in-Play options:
    - 2 or 4 relays, mechanical or solid state, for alarm or control (isolated)
    - 1 or 2 Analog output, 4-20 mA, 0-20 mA, 0-10V, or -10V to +10V (isolated)
    - Communications: Ethernet, WiFi, USB, RS232, RS485 (isolated)
    - Extended DPM includes set up for scaled position or rate, but not forsimultaneous position and rate

The Laureate™ 1/8 DIN Panel Meters for bidirectional position, length or angle measurement

with the Standard counter main board accepts the A & B quadrature signals from shaft encoders or linear encoders to provide a highly accurate, scaled display of position, length, or angle in engineering units, such as ft, cm or degrees. The A & B quadrature signals are 90° out of phase, and their phase relationship determines whether up counts (+) or down counts (-) are counted. The panel meters totalize the counts and then scales the total in software for display and control. A zero index signal, or Z signal, can be added as a third input to the A & B signals.

Bidirectional Rate Measurement

The Laureate™ quadrature meter with the Extended counter main board can be set up for scaled position or rate, but not for simultaneous position and rate. For example, it can display the speed of a moving slab in ft/sec. The display and control output update rate for position or rate is normally set to a maximum of 25/sec, as determined by a user-programmable gate time.

Quadrature Meter Capabilities

  • One, two or four quadrature transitions may be counted at a maximum combined rate of 250 kHz and be mathematically scaled for display in engineering units from -999,999 to +999,999. Maximum pulse rates are 250 kpulses/sec at X1, 125 kpulses/sec at X2, and 62.5 kpulses/sec at X4.
  • Single-ended input signals up to 5V or balanced line driver signals up to 10V are accommodated by the quadrature signal conditioner board. Anti-jitter circuitry eliminates errors due to vibration of the encoder.
  • An excitation output from the panel meters can be used to power the encoder, thus avoiding the need for an external powr supply. Jumper selectable levels are 100 mA at 5V or 120 mA at 10V.
  • A zero index pulse, if available from the encoder, is interpreted by these panel meters as a zero reference for an integral number of revolutions of a rotary encoder, or as the home position of a linear encoder. It is used by these panel meters for initializing and correcting any cumulative pulse count errors. Special circuitry corrects for width of the zero index pulse.
  • In the event of a power failure, the latest total can be stored in non-volatile memory and be used as the starting point for counting when power resumes. Power fail save or zero index capabilities are alternate setup choices for these panel meters.

Unidirectional Position and Rate

If the counts are only for one direction, for example for extrusions measured by an encoder wheel, only the encoder's "A" channel can be used and be output to an Extended Laureate totalizer. This model accommodates very high pulse rates up to 1 MHz, and unlike the quadrature meter, it can simultaneously track rate and total. It can also be programmed for batch control, which allows it to simultaneously track rate, batch (or current) total, and grand total or number of batches.

Laureate Digital Panel Meters are easily programmed with Laurel’s free Instrument Setup Software, downloadable from our website and compatible with Windows PCs, requiring a data interface board for setup.

All signal conditioner board ranges are factory-calibrated, with calibration factors for each range securely stored in an onboard EEPROM. These factors can be scaled via software to accommodate external shunts, enabling field replacement of signal conditioner boards without necessitating recalibration of the associated digital panel meter. For optimal accuracy, factory recalibration is recommended annually. All Laurel Electronics instruments undergo factory calibration using the industry-leading Fluke calibrators, which are recalibrated yearly and certified traceable to national standards, ensuring the highest level of precision and reliability.

Digital signal filtering modes can be selected to ensure stable readings in electrically noisy environments.

  • An unfiltered selection provides true peak and valley readings and aids in control applications.
  • A batch average filter selection averages each 16 conversions.
  • An adaptive moving average filter selection provides a choice of 8 time constants from 80 ms to 9.6 seconds. When a significant change in signal level occurs, the filter adapts by briefly switching to the shortest time to follow the change, then reverts back to its selected time constant. An Auto setting selects the time constant selection based on signal noise.

Peak and valley values are automatically captured. These may be displayed via a front panel pushbutton command or control signal at the rear connector, or be transmitted as serial data.

Two rear panel control Inputs (CMOS/TTL levels, logic 0 = tied to digital ground, logic 1 = open) or dry contacts that can be set to control / activate 14 meter commands.

An (isolated) 5, 10, 12, or 24 Vdc excitation output is standard to power transducers or two-wire transmitters. Ratiometric operation, which automatically compensates for changes in the applied excitation, is jumper selectable for applications, such as bridges, where the signal to be measured is proportional to the excitation level.

Display
Readout 6 LED digits, 7-segment, 14.2 mm (.56"), red or green.
Display Range -999,999 to +999,999, XXXXEX notation beyond 999,999
Zero Adjust -999,999 to +999,999
Span Adjust 0 to ±999,999
Indicators Four LED lamps
Inputs
Types Differential or single-ended quadrature
Transitions Monitored Inputs X1, X2 or X4 (A,B and Z)
Max Pulse Rate 250 kpulses/sec at X1, 125 kpulses/sec X2, 62.5 kpulses/sec at X4
Position Error No error contributed by meter
Differential High Threshold +200 mV
Differential Low Threshold -200 mV
Differential Limits -11V to +14V
Single-ended High Voltage 2.5V to 10V
Single-ended Low Voltage -1V to +1V
Input Resistance, Typ. 17 kOhm
Recalibration: All ranges are calibrated at the factory. Recalibration is recommended every 12 months.
Quadrature Position Mode
Zero Adjust -999,999 to +999,999
Span Adjust 0 to ±999,999
Quadrature Rate Mode
Freq. Technique Inverse period
Conversion Time Gate time + 30 ms + 0-2 signal periods
Gate Time Selectable 10 ms to 199.99 s
Time Before Zero Out Selectable 10 ms to 199.99 s
Output & Display Update Same as conversion time
Time Base Accuracy Calibrated to ±2 ppm
Power Supply Boards (one required)
Voltage, standard 85-264 Vac or 90-300 Vdc
Voltage, optional 12-32 Vac or 10-48 Vdc
Frequency DC or 47-63 Hz
Power Consumption (typical, base meter) 1.2W @ 120 Vac, 1.5W @ 240 Vac, 1.3W @ 10 Vdc, 1.4W @ 20 Vdc, 1.55W @ 30 Vdc, 1.8W @ 40 Vdc, 2.15W @ 48 Vdc
Power Isolation 250V rms working, 2.3 kV rms per 1 min test
Excitation Output (standard)
5 Vdc 5 Vdc ± 5%, 100 mA (jumper selectable)
10 Vdc 10 Vdc ± 5%, 120 mA (jumper selectable)
12 Vdc 12 Vdc ± 5%, 100 mA (jumper selectable)
24 Vdc 24 Vdc ± 5%, 50 mA (jumper selectable)
Output Isolation 50 Vdc from signal ground
Analog Output Boards (one optional)
Output levels 4-20 mA, 0-20 mA, 0-10V, -10 to +10V (single-output option)
Current compliance 2 mA at 10V ( > 5 kΩ load)
Voltage compliance 12V at 20 mA (< 600 Ω load)
Scaling Zero and full scale adjustable from -99999 to +99999
Resolution 16 bits (0.0015% of full scale)
Isolation 250V rms working, 2.3 kV rms per 1 min test
(dual analog outputs share the same ground)
Relay Output Boards (one optional)
Dual magnetic relays 2 Form C, 10A max, 440Vac or 125Vdc max, 2500VA or 300W
Quad magnetic relays 4 Form A (NO), 10A max, 440Vac or 125Vdc max, 2500VA or 300W
Dual solid state relays 2 Form A (NO), AC or DC, 0V - 400V, 120Ma, 35Ohms (max at On-State)
Quad solid state relays 4 Form A (NO), AC or DC, 0V - 400V, 120Ma, 35Ohms (max at On-State)
Relay commons Isolated commons for dual relays or each pair of quad relays
Relay isolation 250V rms working, 2.3 kV rms per 1 minute test
Relay latching modes Latching or non-latching
Relay active modes Active on or off, active high or low
Hysteresis modes QA passband mode, split hysteresis, span hysteresis
Communication Boards (one optional)
Board selections RS232RS485 with dual RJ11 connectors, RS485 with dual RJ45 connectors, USB, Ethernet, USB-to-RS485 gatewayEthernet-to-RS485 gateway, WiFi with built-in antenna plus USB & RS485, WiFi with external antenna plus USB & RS485
Protocols Laurel Custom ASCII (serial), Modbus RTU (serial), Modbus TCP (Ethernet or WiFi)
Digital addresses 247 (Modbus), 31 (Laurel ASCII),
Isolation 250V rms working, 2.3 kV rms per 1 min test
Environmental
Operating temperature -40°C to 70°C (-40°F to 158°F)
Storage temperature. -40°C to 85°C (-40°F to 185°F)
Relative humidity 95% at 40°C, non-condensing
Protection NEMA-4X (IP-65) when panel mounted
Mechanical
Enclosure 1/8 DIN, high impact plastic, UL 94V-0, color: black
Mounting 1/8 DIN panel cutout required: 3.622" x 1.772" (92 mm x 45 mm).
Dimensions 4.68" x 2.45" x 5.64" (119 mm x 62 mm x 143 mm) (W x H x D)
Maximum panel thickness 4.5 mm (0.18")
Tightening Torque - Connectors Screw terminal connectors: 5 lb-in (0.56 Nm)
Tightening Torque - Pawls Digital Panel Meter Case Pawls: 5 lb-in (0.56 Nm)
Weight of base meter 210 g (7.4 oz) typical (DPM, counter, timer, 6-digit remote display)
Weight of option boards 30 g (1.0 oz) typical per board (analog output, relay output, communications)
General
Programming Methods Four front panel buttons or via Laurel's free Instrument Setup Software, which runs on a PC under MS Windows. 
Security Lockout options include using the front panel buttons, the free Instrument Setup Software, or a hardware jumper.
Warranty 3 years parts & labor
Recalibration: All ranges are calibrated at the factory. Recalibration is recommended every 12 months.

Free Instrument Setup Software for Series 2 Laureates

Digital Panel Meter Laurel Electronics Digital Transmitters
1/8 DIN Digital Panel Meters DIN Rail Transmitters

Free Downloadable Windows-based Instrument Setup (IS) software (Data Interface Board Required) for use with our programmable Digital Panel Meters, Scale Meters, Counters, Timers, Remote Displays, and Transmitters, are an easy method to set up Laureate 1/8 DIN digital panel meters, counters, timers, remote displays, and DIN-rail transmitters, as explained in the Instrument Setup Software Manual. Laureate 1/8 DIN instruments can also be set up from the front panel, as explained in their respective Owners Manuals. Instrument Setup software is of benefit whether or not the PC is connected to the instrument.

  • When the PC is connected to the instrument, Instrument Setup software can retrieve the setup file from the instrument or open a default setup file or previously saved setup file from disk View Setup, then provides graphical user interface (GUI) screens with pull-down menus applicable to input, display, scaling, filtering, alarms, communications, analog output, and front panel lockouts. Fields that are not applicable to the instrument as configured are either left out or grayed out. Clicking on any item will bring up a detailed Help screen for that item. After editing, the setup file can be downloaded, uploaded to the instrument, or saved to a disk. The same setup file can then be downloaded into multiple instruments.
  • When the PC is not connected to the instrument, the above GUI screens can be used to set up a virtual instrument. The setup file can then be saved to disk. Switching toView Menu then brings up a screen with the required front panel programming steps. This view can be printed out for use at the instrument site and to serve as a hard copy record.

    Download Free Instrument Setup Software


Installation

Set User Account Control (UAC) of MS Windows to "Never notifiy me" so that Instrument Setup Software can create directories. The UAC change screen can be reached as follows:

  • Under Windows 7, click on the Windows Start button in the lower left of the desktop and enter "UAC" in the search field.
  • Under Windows 8, navigate to Control Panel, then to the "User Accounts and Family Safety" section, and click on "Change User Account Control Settings."
  • Under Windows 10, click on the Windows Start button in the lower left of the desktop, then on "Settings", and enter "UAC" in the search field.
  • Reboot your computer for the changed UAC setting to take effect.
Meter board with USB Type-B connector

RJ11-to-DB9 cable with rear view of DB9 connector to PC

Laurel USB cable, P/N CBL05

RS232 cable, meter to PC, P/N CBL01

Laureate 1/8 DIN Laureate instruments must be equipped with a serial communications board and be connected to the computer via a serial communications cable. The connection can be via RS232, RS485, USB or Ethernet. Following setup, the serial communications board may be removed from the instrument if desired. The wiring of the RS232 cable is illustrated above with end views of the two connectors.

Laureate LT Series transmitters come standard with a 3-wire serial interface, which can be jumpered for RS232 or RS485.
Laureate LTE Series transmitters come standard with an Ethernet interface.

Meter Setup Screens

Click on any of the reduced screens below for a full-size screen view, then click on the Back button of your browser to return to this page. The screens examples below are for a fully-loaded Series 2 Digital Panel Meter (DPM), which is connected to the PC via RS232. If the meter is a Series 1 meter (pre-2007), this is sensed by the software, and somewhat different screens are brought up. Please see Series 1 setup screens.

Laurel Dual Channel Pulse Input Rate Meter
Welcome Screen
From the computer desktop, click on Start > Programs > IS2 > IS2. Or click on the IS icon on your desktop. This splash screen will be displayed for three seconds. The software revision number is in the lower right.
more
Setup Screen 02s for Digital Panel Meters and Digital Transmitters
Communications Selection Screen
Specify your desired communication protocol and the serial communications bus type, which should match the jumper setup of the instrument. Select None if the PC is not connected to the instrument.
more
Setup Screen 3 for Digital Panel Meters and Digital Transmitters
Establish Communications Screen
If you selected RS-232, you will be asked to specify the PC Com Port and Baud Rate, which should match the jumper setup of the instrument. Click on Establish. With the right settings, the Communications Established field will light up in green, and the Meter Type will be recognized. If so, click onMain Menu.
more
Setup Screen 4 for Digital Panel Meters and Digital Transmitters
Main Menu Screen
Click on File > Default Setup to retrieve the default setup file from disk for your type of meter. Click on File > Open Setupto retrieve a previously saved setup file from disk or on File > Save Setup to save your edited setup file to disk. Click onDPM > Get Setup to retrieve the setup file from your meter or on DPM > Put Setup to download your edited setup file into the meter.
more
Setup Screen 5 for Digital Panel Meters and Digital Transmitters
DPM Input + Display Setup Screen
From the Main Menu, click on View > Setup, then on theInput+Display tab. You can now specify the meter hardware, signal type, display mode, and functions of control inputs A and B. Clicking on any item brings up a pull-down menu with the available choices.
more
Setup Screen 6 for Digital Panel Meters and Digital Transmitters
DPM Scaling Setup Screen
Click on the Scaling tab, which provides three scaling methods to relate the signal to the displayed reading: 1) Scale and Offset method, 2) Coordinates of two points method, and 3) Reading Coordinates of Two Points method. The last method uses actual high and low signals, and the computer will prompt you.
more
Setup Screen 7 for Digital Panel Meters and Digital Transmitters
DPM Filter Setup Screen
Click on the Filter tab, which allows you to specify the digital filter time constant (if any), the adaptive filter threshold, and whether Peak / Valley values are filtered or unfiltered. As for all setup screens, clicking on the F1 key while an item is highlighted brings up a Help screen for that item, as illustrated.
more
Setup Screen 8 for Digital Panel Meters and Digital Transmitters
DPM Relay Alarms Setup Screen
Click on the Relay Alarms tab, which allows you to set up Alarms 1 and 2 for the optional dual relay output board. Clicking on any of the four numeric fields changes these to green and brings up a special field to enter the desired numeric value, which is tied to the displayed reading.
more
Setup Screen 9 for Digital Panel Meters and Digital Transmitters
DPM Communications Setup Screen
Click on the Communications tab so set up serial communications. In particular, you can special the Serial Protocol and the meter address if multiple meters are to be addressed on the same serial data line.
more
Setup Screen 10 for Digital Panel Meters and Digital Transmitters
DPM Analog Output Setup Screen
Click on the Analog Out tab so set up the optional analog output board. Three output ranges are selectable, the endpoints of which can be tied to user-specified High and Low readings.
more
Setup Screen 11 for Digital Panel Meters and Digital Transmitters
DPM Lockouts Setup Screen
Click on the Lockouts tab to check off menu items which will no longer be accessible from the front panel of the meter. This will simplify meter operation and prevent unintended setup changes.
more

Meter Setup Utilities

Setup Screen 12 for Digital Panel Meters and Digital Transmitters
DPM Front Panel Setup Screen
As an aid to programming the meter from the front panel when a serial connection is not available, you can return to the Main Menu and click on View > Menu. The required sequence of front panel screens will then be displayed. Click on any step in the sequence for the meaning of each digit, as illustrated for the FILtEr step. For a hardcopy, simply press on Print.
more
Setup Screen 13 for Digital Panel Meters and Digital Transmitters
DPM Jumper Setup Screen
Specify your desired communication protocol and the serial communications bus type, which should match the jumper setup of the instrument. Select None if the PC is not connected to the instrument.
more
Setup Screen 14 for Digital Panel Meters and Digital Transmitters
DPM Jumper Setup Screens
Click on any of the displayed plug-in boards, and you will be presented with the jumper positions and electrical connections for your selected board. This minimizes the need to refer to the printed manual.
more
Setup Screen 15 for Digital Panel Meters and Digital Transmitters
DPM Commands Screen
This page allows you set up external input, serial communications, an analog output proportional to the display (optional), and lockouts for Laureate digital counters. The grayed out area at the top right of the screen applies to Laureate remote displays.
more
Graphical Output Screens (not available with Ethernet)

From the Main Menu, click on Readings if your PC is connected to the meter. A pull-down menu then offers three choices: ListPlot and Graph.

  • List presents the latest readings in a 20-row by 10-column table. Press Pause at any time to freeze the display. This is one method to capture peak readings.   
  • Plot generates a plot of readings vs. time in seconds. It effectively turns the DPM-PC combination into a printing digital oscilloscope.
    more 
  • Graph generates a histogram where the horizontal axis is the reading and the vertical axis is the number of occurrences of readings. The display continually resizes itself as the number of readings increases.
    more
Setup Screen 18 for Digital Panel Meters and Digital Transmitters
DPM Calibration Screens
Click on the Scaling tab, which provides three scalClick on the Scaling tab, which provides three scaling methods to relate the signal to the displayed reading: 1) Scale and Offset method, 2) Coordinates of two points method, and 3) Reading Coordinates of Two Points method. The last method uses actual high and low signals, and the computer will prompt you.
more
Setup Screen 19 for Digital Panel Meters and Digital Transmitters
Frequency Meter Calibration Screen
Calibration of the quartz crystal of the Laureate frequency meter requires the input of a known frequency from a calibrator. Apply the frequency, then enter the frequency in Hertz. Calibration will be automatic, with storage of the calibration factor stored in non-volatile memory.
more

 

Laureate™ 1/8 DIN Case For Laureate Digital Panel Meters, Counters, Timers & Remote Displays

Laurel panel meter case

Key Features

  • Meets 1/8 DIN Standard.
  • Installs from front of panel.
  • Short depth behind the panel: only 4" (102 mm) plus connectors.
  • Understated 0.157" (4 mm) thick bezel.
  • Meets NEMA 4X (IP-65) for high-pressure wawshdon when panel mounted.
  • Screw clamps connectors meet VDE / IEC / UL / CSA safety standards.
  • Rugged GE Lexan® housing material.
  • Safety certified per EN 61010-1.
CE CertifiedRoHs CertifiedETL Certified

Dimensions

Mechanical specifications of Laureate digital panel meters and electronic counters

Maximum panel thickness: 4.5 mm (0.18")
Weight of base meter:
210 g (7.4 oz) typical (DPM, counter, timer, 6-digit remote display)
Weight of option boards: 30 g (1.0 oz) typical per board (analog output, relay output, communications)
Tightening Torque - Connectors: Screw terminal connectors: 5 lb-in (0.56 Nm)
Tightening Torque - Pawls: Digital Panel Meter Case Pawls: 5 lb-in (0.56 Nm)
Dimensioned CAD assembly drawings in EPRT, STEP, x_t. dwg, pdf file formats: Laureate-meter-case.zip (zipping prevents browser from opening CAD files as text files).

Panel Mounting

Mechanical Panel Mounting GuideSlide the meter into a 45 x 92 mm 1/8 DIN panel cutout. Ensure that the provided gasket is in place between the front of the panel and the back of the meter bezel. The meter is secured by two pawls, each held by a screw, as illustrated. Turning each screw counterclockwise extends the pawl outward from the case and behind the panel. Turning each screw clockwise further tightens it against the panel to secure the meter.

Turning each screw counterclockwise loosens the pawl and retracts it into its well. This position allows installed meter to be removed from their panel, or new meters to be installed in a panel. Do not remove the screws from their pawls. Doing so would cause the screw and pawl to fall off and likely get lost. Do not overtighten so as not to damage the plastic parts.

 

Using Quadrature for Cutting to Length
Using a Laureate quadrature panel meter to cut material to length Controlling the repetitive cutting of material to length is an excellent application of the Laureate quadrature meter. The quadrature encoder shares the shaft of a sensing wheel, whose rotation corresponds to lineal displacement of material. The meter compares the displacement reading against setpoint information, and then uses its dual relays to first slow down and then cut the material.
Using Quadrature for X-Y Positioning
Using a Laureate quadrature panel meter for X-Y positioning Accurate X-Y position or rate can be obtained from two shaft encoders, which convert linear position to quadrature signals as a shaft turns. In addition to serving as a display, each Laureate can use its optional dual relay setpoint capability for closed loop control. It can also transmit data via RS232, RS485, or a 4-20 mA analog signal.
Using Quadrature to Monitor a Drilling Operation
Using a Laureate quadrature meter to monitor an oil drilling operation Quadrature can be used to track position and vertical drilling speed of the bit in an oil drilling operation. A shaft encoder is rotated by a cable that moves with the drilling shaft. In this application, the same encoder signal is applied to a Laureate quadrature meter for position, and to a second quadrature meter for rate. Both meters can be scaled to read out in appropriate engineering units, such as feet and inches per minute, and can be alarmed. A Laureate 6-digit remote display could be added to read out peak rate.

 

 

CAL-Digital

Certificate of Calibration

$65.00

DLS-XLOG2

XLog2 Data logging Software

$495.00

IPC

Splashproof Cover

$55.00

CON01

CON01 Connector

$75.00

CBL01

RS232 Cable for Meters

$35.00

CBL02

USB-to-RS232 Adapter Cable

$47.00

CBL04

RS232 Cable for LT Transmitters

$47.00

CBL05

USB Data Cable for Meters

$47.00

CBL06

USB-to-RS485 Adapter Cable

$47.00

CBL07

USB Programming & Data Cable

$47.00

CBL08

RS485 Splitter Cable

$33.00

CBL6

6-foot Power Cable

$41.00

CBL12

12-foot Power Cable

$47.00

Modular Design for Maximum Flexibility at Minimum Cost

All boards are isolated from meter and power grounds. Optional Plug-in-Play boards for communications and control include Ethernet, WiFi, serial communication boardsdual or quad relay boards, and an analog output board. Laureates may be powered from 85-264 Vac or optionally from 12-32 Vac or 10-48 Vdc. The display is available with bright red or green 0.56" (14.2mm) high LED digits. The 1/8 DIN case meets NEMA 4X (IP65) specifications from the front when panel mounted. Any setup functions and front panel keys can be locked out for simplified usage and security. A built-in 5, 10, 12, or 24 Vdc excitation supply can power transducers, eliminating the need for an external power supply. All power and signal connections are via UL / VDE / CSA rated screw clamp plugs.

The Laureate™ Series features modular design with up to 7 isolated plug-in boards, applicable to all Laureate 1/8 DIN Panel Meters.

Schematic for Digital Panel Meter

Modular Hardware

The design of the Laureate™ Series is modular for maximum flexibility at minimum cost. All boards are isolated from meter and power grounds. The base configuration for panel meters or counter consists of a main module (with computer and plug-in display boards), a power supply board, and a signal conditioner board. Optional plug-in-play boards include an isolated setpoint controller board, an isolated analog output board, and an isolated digital interface board. Modular design and a choice of plug-in options allow the Laureate to be customized for a broad range of applications from simple monitoring to control and computer interface. There can be up to five plug-in boards in a 1/8 DIN Laureate.

Dual Board sets

Connecting Laureate Panel Meters to a Local Area Network (LAN)

Up to 30 Laureate Panel Meters and/or LT Transmitters can be configured for RS485 and daisy-chained to an LT Transmitter using Laurel’s High Speed Ethernet-to-RS485 converter board for seamless LAN integration. Alternatively, Laurel LTE series Ethernet transmitters can connect directly to a LAN via an Ethernet cable. Setup for both configurations is streamlined using Laurel’s free Instrument Setup Software, which simplifies node discovery and transmitter configuration.

Flexible Communication Options for Panel Meters

Laureate Panel Meters can be equipped with Laurel communication boards to support various interfaces and protocols. These include serial interfaces with ASCII or Modbus RTU protocols, and Ethernet interfaces with web access, ASCII, or Modbus TCP/IP protocols, ensuring versatile connectivity for your commercial applications.

Laurel network with Ethernet-to-analog converter board

Ordering Guide
Part Number as Configured: L7101FQD
Price as Configured: $789.00

Click on the Option Board Links for More Product Information

Base Item
$169.00
Display Color
$0.00
$0.00
$41.00
$41.00
Power (Isolated) $75.00
$115.00
Relay Output (Isolated)
$0.00
$101.00
$70.00
$128.00
$96.00
Analog Output (Isolated)
$0.00
$115.00
$172.00
Data Interface (Isolated)
$0.00
$81.00
$109.00
$135.00
$81.00
$135.00
$237.00
$259.00
$182.00
$204.00
$171.00
$193.00
$204.00
$226.00
Signal Input (Isolated)
$123.00
Part Number as Configured:
L7101FQD
Price as Configured:
$789.00
Quantity:
- +
Extended Price:
$789.00

Understanding the Laureate™ 1/8 DIN Panel Meters for Quadrature Encoder Input and Bidirectional Position or Rate

The Laureate™ 1/8 DIN Panel Meters for bidirectional position, length, or angle measurement accepts A & B quadrature signals from shaft encoders or linear encoders to provide a highly accurate, scaled display in engineering units like ft, cm, or degrees. The A & B signals are 90° out of phase, and their phase relationship determines whether up counts (+) or down counts (-) are registered. A zero index (Z) signal can be added as a third input.

Counting Modes and Maximum Rates

One, two, or four quadrature transitions may be counted at a maximum combined rate of 250 kHz, mathematically scaled for display from -999,999 to +999,999. Maximum pulse rates are 250 kpulses/sec at X1, 125 kpulses/sec at X2, and 62.5 kpulses/sec at X4. Position error contributed by the meter itself is documented as none — accuracy is governed by the encoder, not the meter's processing.

Input Signal Specifications

Single-ended input signals up to 5V or balanced line driver signals up to 10V are accommodated. Differential high/low thresholds are ±200 mV, with differential limits of -11V to +14V; single-ended high voltage is 2.5V to 10V, low voltage is -1V to +1V, with 17 kΩ typical input resistance. Anti-jitter circuitry eliminates errors from encoder vibration.

Excitation, Zero Index, and Power-Fail Behavior

An excitation output can power the encoder directly, avoiding an external supply — jumper-selectable at 100 mA at 5V or 120 mA at 10V. A zero index pulse, if available, serves as a reference for an integral number of revolutions (rotary) or the home position (linear), correcting cumulative pulse count errors; special circuitry compensates for the width of the zero index pulse. Alternatively, in the event of a power failure, the latest total can be stored in non-volatile memory as the restart point. Power-fail-save and zero-index correction are documented as alternate setup choices, not simultaneous features.

Position vs. Rate — Not Simultaneous

The Extended counter main board can be set up for scaled position or rate, but not simultaneous position and rate. Update rate for either is normally up to 25/sec, set by a user-programmable gate time.

Unidirectional Alternative

If counts are needed in only one direction — for example, extrusion measured by an encoder wheel — only the encoder's "A" channel can be used, output instead to an Extended Laureate totalizer. That model accommodates pulse rates up to 1 MHz and, unlike the quadrature meter, can simultaneously track rate and total, and can also be programmed for batch control tracking rate, batch total, and grand total together.

Real-World Applications

  • Cutting to Length — the encoder shares a sensing wheel's shaft, whose rotation corresponds to linear material displacement; the meter compares displacement against setpoints and uses dual relays to slow, then cut.
  • X-Y Positioning — two shaft encoders convert linear position to quadrature signals; each meter can use dual relay setpoints for closed-loop control and transmit via RS232, RS485, or 4-20 mA.
  • Monitoring a Drilling Operation — a shaft encoder rotated by a cable moving with the drilling shaft feeds one meter for position and a second meter for rate, both scaled to engineering units like feet and inches/minute and alarmed; a remote display can add peak rate readout.

Factory-Calibrated Accuracy

All signal conditioner board ranges are factory-calibrated, with calibration factors stored in EEPROM. Field replacement of the signal conditioner board doesn't require recalibrating the meter. Factory recalibration is recommended annually.

Where Quadrature Encoder Panel Meters Are Used

  • Cut-to-Length & Slitting Lines — precise material length control with slowdown/cut relay sequencing.
  • Gantry & X-Y Positioning Systems — dual-axis position and closed-loop setpoint control.
  • Oil & Gas Drilling Instrumentation — real-time bit position and rate-of-penetration monitoring.
  • Extrusion & Web Handling — unidirectional length/rate tracking via encoder wheel contact.
  • CNC & Machine Tool Retrofits — position readout for axes lacking native digital position feedback.
  • Elevator & Hoist Position Monitoring — bidirectional position tracking for reversible vertical motion.
  • Test Stand & Dynamometer Instrumentation — position and rate feedback for R&D and validation rigs.

Quadrature Encoder Panel Meter Frequently Asked Questions

Why does maximum pulse rate drop from 250 kHz at X1 down to 62.5 kHz at X4?

X4 counting registers four transitions per quadrature cycle instead of one, so for the same maximum combined processing rate of 250 kHz, the number of complete cycles per second the meter can track is correspondingly divided by four — the tradeoff is finer resolution (more counts per revolution or per unit of travel) in exchange for a lower maximum encoder shaft speed or linear velocity the meter can accurately follow at that counting mode.

What does it mean that the meter contributes "no error" to position measurement?

This is documented specifically as isolating the source of any position inaccuracy — since the meter's internal counting itself introduces essentially no error, any position error observed in a real installation traces back to the encoder itself (mechanical coupling, resolution limits, electrical noise) or to the physical setup, rather than to the meter's processing, which is a useful distinction when troubleshooting an accuracy complaint.

Can I use both zero index correction and power-fail-save memory on the same meter at the same time?

No — these are documented specifically as alternate setup choices, not simultaneous features. An installation needs to choose one approach: either rely on a physical zero index pulse from the encoder to periodically re-reference position, or rely on non-volatile memory retaining the last known total through a power interruption, but not configure both mechanisms together.

If I need both position and rate displayed at the same time from one quadrature signal, what are my options?

Since the quadrature meter itself is documented as supporting position or rate but not both simultaneously, one documented solution is to apply the same encoder signal to two separate meters — one configured for position, one for rate — as shown in the drilling operation application, where this exact approach is used to get both readings simultaneously from a single encoder.

Why does the differential input have such a wide voltage limit range (-11V to +14V) compared to its much narrower threshold (±200 mV)?

These describe two different things: the ±200 mV threshold is the small voltage difference between the differential pair that the meter actually uses to register a logic transition, while the -11V to +14V range describes the much wider common-mode and signal range the input circuitry can tolerate without damage — this wide tolerance range provides robustness against ground potential differences and noise, while the sensitive threshold is what determines actual signal detection.

Does the excitation output eliminate the need to check an encoder's voltage compatibility with the meter?

No — the jumper-selectable 5V or 10V excitation output specifically needs to match what the connected encoder actually requires to operate, so confirming the encoder's rated supply voltage against the available 5V/100mA or 10V/120mA excitation options is still necessary; the excitation output removes the need for a separate external power supply, but doesn't automatically guarantee voltage compatibility with any given encoder.

In the unidirectional totalizer alternative, why can it reach 1 MHz when the quadrature meter itself tops out at 250 kHz?

Using only a single channel (A) rather than processing the full quadrature relationship between two channels simplifies the counting task considerably, and the documented unidirectional totalizer is specifically a different meter configuration (the Extended Laureate totalizer) built for high-speed single-channel counting rather than quadrature decoding — the higher rate reflects a genuinely different, simpler internal signal path rather than the same hardware operating faster.

Does the cut-to-length application's slow-down-then-cut relay sequence require the Extended counter, or does it work with the Standard counter?

The documented cut-to-length application specifically describes using dual relays for slowdown and cut — this relay-based control functionality is generally tied to having the appropriate relay output board installed rather than specifically requiring the Extended counter main board, though confirming the exact board combination needed for a specific setpoint configuration is worth verifying against the current product documentation.

Can the X-Y positioning application's two meters be networked together, or does each operate as a fully independent display?

Documented capability specifically notes each meter in the X-Y positioning application can transmit data via RS232, RS485, or 4-20 mA analog signal — this means the two axis meters aren't limited to standalone local display and control; their position and rate data can be centralized to a PLC, SCADA system, or data logger alongside their independent local relay-based closed-loop control.

Does the anti-jitter circuitry eliminate all vibration-related counting errors, or only reduce them?

Documented capability specifically describes this circuitry as eliminating errors due to encoder vibration, addressing the specific failure mode where mechanical vibration causes an encoder shaft to oscillate slightly back and forth across a transition point, which without correction could register as spurious extra counts in both directions — this is a targeted fix for that specific vibration-induced miscounting behavior rather than a general noise filter for unrelated electrical interference sources.

X1/X2/X4 Quadrature Decoding & Encoder Resolution Questions From the Field

What's actually different between X1, X2, and X4 decoding at the signal level?

Documented technical explanations specifically describe X1 as counting only one edge (rising or falling, depending on direction) of a single channel; X2 as counting both the rising and falling edges of that same single channel, doubling the pulse count; and X4 as counting both rising and falling edges of both channels A and B together, quadrupling the pulse count — the underlying encoder disk and physical signal don't change, only how many of the available edges the counting circuitry actually registers.

If an encoder is rated for 1000 PPR, what resolution do I actually get using X2 or X4 decoding?

Documented examples specifically show a 1000 PPR encoder with X2 decoding yielding an effective 2000 PPR, and the same encoder with X4 decoding yielding 4000 PPR — the encoder's base PPR rating is multiplied directly by the decoding factor (×2 or ×4), meaning the manufacturer's stated PPR number alone doesn't tell you the resolution actually achieved without knowing which decoding mode the receiving instrument uses.

Does choosing a higher decoding mode like X4 always improve overall system accuracy, or just resolution?

Documented industry references specifically distinguish these as related but separate concepts — X4 decoding genuinely increases resolution (finer position increments), and is documented in at least one case as remaining accurate to better than ±1 count even at the higher multiplication, but overall system accuracy also depends on the encoder's own mechanical and optical precision, not purely on the decoding mode selected at the counting instrument.

Why is direction detection only possible with two channels (A and B), not with a single-channel pulse output?

Documented explanation specifically notes that a single pulse channel alone only allows counting — it can tell you how much movement occurred, but not which way — while a second channel offset by 90 degrees lets the counting circuitry determine direction by observing which channel's edge arrives first (leads) relative to the other, which is the actual mechanism that makes quadrature output "quadrature" and enables both position and direction to be determined together.

Does an encoder's maximum electrical speed rating change depending on which decoding mode (X1, X2, X4) is used downstream?

Yes — documented analysis specifically works through this: an encoder's maximum electrical speed is capped by how fast its output electronics can switch relative to its rated frequency response, and since X2 or X4 decoding multiplies the effective PPR the receiving instrument must keep up with, a documented example shows the same encoder's maximum usable electrical speed dropping significantly (2400 rpm at X1 down to 1200 rpm at X2) purely because of the decoding mode chosen, even though the physical encoder itself is unchanged.

Is X4 decoding accomplished through additional physical channels on the encoder, or purely through how the receiving instrument processes the existing A/B signals?

Documented explanation specifically confirms this is a processing choice at the receiving/counting end, not an additional physical encoder output — the same two-channel A/B quadrature signal is used for X1, X2, or X4 decoding; what changes is purely how many of the available signal edges (rising and falling, on one or both channels) the counter or PLC's decoding logic chooses to register as counts.

Does differential (line driver) encoder output offer a genuine noise-immunity advantage over single-ended output, separate from the X1/X2/X4 decoding choice?

Yes — documented technical guidance specifically notes that differential output improves noise immunity by transmitting each channel's signal as a matched pair, which lets the receiving circuitry reject common-mode noise picked up along the cable run, an advantage that's independent of and complementary to whichever decoding mode (X1/X2/X4) is subsequently applied to the recovered signal.

Can resolution multiplication (X2/X4) be combined with internal encoder interpolation to push resolution even higher than the base disk resolution would suggest?

Yes — documented examples specifically describe combining electronic interpolation within the encoder itself (which increases the encoder's own native cycles-per-revolution beyond what the physical disk pattern alone provides) with downstream X2 or X4 resolution multiplication at the counting instrument, compounding both techniques to reach resolutions substantially higher than either technique alone would achieve from the same physical encoder disk.