Panel Meters for Time Interval of Periodic Events Applications P/N L8110EFR

Panel Meters for Time Interval of Periodic Events Applications

Price: $711.00
  • P/NL8110EFR
- +

Features

  • Times periodic events with width from 1 µs to 199.999 s
  • Transmits average time of periodic events with width from 1 µs to 199.999 s
  • Resolution to 0.2 µs, rep rated to 250 kHz
  • Inputs from NPN or PNP proximity switches, contact closures, digital
    logic, magnetic pickups down to 12 mV, or AC inputs up to 250 Vac
  • Trigger on positive or negative pulse edges
  • Digital span adjust from 0 to ±999,999, zero adjust from -999,999 to +999,999
  • Front panel scalable: to ±999,999 for use with current shunts
  • 1/8 DIN size with bright red or green 0.56" (14.2mm), high LED digits
  • Transducer excitation output, 5, 10, 12, or 24 Vdc (isolated)
  • Power 85-264 Vac / 90-300 Vdc or 10-48 Vdc / 12-32 Vac (isolated)
  • Operating temperature from -40°C to 70°C  (-40°F to 158°F)
  • Wide choice of Plug-in-Play options:
    - 2 or 4 relays, mechanical or solid state, for alarm or control (isolated)
    - 1 or 2 Analog output, 4-20 mA, 0-20 mA, 0-10V, or -10V to +10V (isolated)
    - Communications: Ethernet, WiFi, USB, RS232, RS485 (isolated)
    - Extended DPM includes rate and total simultaneously, dynamic up-down counting, arithmetic functions

Signal conditioner board for Laureate stopwatch meter

The Laureate™ 1/8 DIN Panel Meters for A-to-B Time Interval

 can display pulse width or time delay between individual pulses to a resolution of 0.2 µs. It can also display average pulse width or average time delay between multiple pulses.

Time interval is measured between inputs on channels A and B. Timing starts when a pulse is applied to Channel A (selectable positive or negative edge), and ends when a pulse is applied to Channel B (selectable positive or negative edge). In case of a single pulsed signal, the A and B inputs can be tied together. A positive or negative slope may be selected to start timing, and the opposite slope must be selected to stop timing. Timing is achieved by counting 5.5 MHz clock pulses. Multiple integral time intervals are averaged over a gate time which is selectable from 10 ms to 199.99 s and also controls the display update time.

Time interval can be displayed in seconds, milliseconds, or microseconds with 6-digit resolution. In the typical application, time is displayed in milliseconds with 1 µs resolution. For times less than 100 ms, display resolution down to 0.2 µs can be achieved by applying a multiplier of 10, moving the decimal point by one position, and averaging many time intervals.

Highly accurate rate can be displayed by taking the inverse of time. Extensive arithmetic capabilities allow display in engineering units, such as meters/sec. An Extended main board version offers all features of Standard main board plus rate based on 1/time.

The FR dual-channel signal conditioner board accepts inputs from proximity switches with a PNP or NPN output, TTL or CMOS logic, magnetic pickups, contact closures, and other signals from 12 mV to 250 Vac. Jumper selections provide optimum operation for different sensor types and noise conditions. A built-in (isolated) 5, 10, 12, or 24 Vdc excitation supply can power proximity switches and other sensors, and eliminate the need for an external power supply.

Extended DPM includes rate and total simultaneously, dynamic up-down counting, arithmetic functions applicable to channels A & B (A+B, A-B, A/B, AxB, A/B-1), phase angle, power factor, duty cycle, batch control, custom curve linearization.

Laureate Panel Meters are easily programmed with Laurel’s free Instrument Setup Software, downloadable from our website and compatible with Windows PCs, requiring a data interface board for setup.

All signal conditioner board ranges are factory-calibrated, with calibration factors for each range securely stored in an onboard EEPROM. These factors can be scaled via software to accommodate external shunts, enabling field replacement of signal conditioner boards without necessitating recalibration of the associated panel meters. For optimal accuracy, factory recalibration is recommended annually. All Laurel Electronics instruments undergo factory calibration using the industry-leading Fluke calibrators, which are recalibrated yearly and certified traceable to national standards, ensuring the highest level of precision and reliability.

Digital signal filtering modes can be selected to ensure stable readings in electrically noisy environments.
  • An unfiltered selection provides true peak and valley readings and aids in control applications.
  • A batch average filter selection averages each 16 conversions.
  • An adaptive moving average filter selection provides a choice of 8 time constants from 80 ms to 9.6 seconds. When a significant change in signal level occurs, the filter adapts by briefly switching to the shortest time to follow the change, then reverts back to its selected time constant. An Auto setting selects the time constant selection based on signal noise.

Peak and valley values are automatically captured. These may be displayed via a front panel pushbutton command or control signal at the rear connector, or be transmitted as serial data.

Two rear panel control Inputs (CMOS/TTL levels, logic 0 = tied to digital ground, logic 1 = open) or dry contacts that can be set to control / activate 14 meter commands.

An (isolated) 5, 10, 12, or 24 Vdc excitation output is standard to power transducers or two-wire transmitters. Ratiometric operation, which automatically compensates for changes in the applied excitation, is jumper selectable for applications, such as bridges, where the signal to be measured is proportional to the excitation level.

Display
Readout 6 LED digits, 7-segment, 14.2 mm (.56"), red or green.
Range -999,999 to +999,999
Indicators Four LED lamps
Inputs
Types AC, pulses from NPN, PNP transistors, contact closures, magnetic pickups.
Signal Ground Common ground for channels A & B
Channel A Freq. 0 Hz to 1 MHz
Channel B Freq. 0 Hz to 250 kHz
Minimum Signal Nine ranges from (-12 to +12 mV) to (+1.25 to +2.1V).
Maximum Signal 250 Vac
Noise Filter 1 MHz, 30 kHz, 250 Hz (selectable)
Recalibration: All ranges are calibrated at the factory. Recalibration is recommended every 12 months.
Time Interval Mode
Timing Start Channel A pulse, + or - edges
Timing Stop Channel B pulse, + or - edges
Periodic Timing Interval Gate time + 30 ms + 0-2 time intervals
Gate Time Selectable 10 ms to 199.99 s
Time Before Zero Output Selectable 10 ms to 199.99 s
Resolution
0 - 199.999 s 1 ms
0 - 99.9999 s 100µs
0 - 9.99999 s 10 µs
0 - .999999 s 1 µs
0 - .099999 s 0.2 µs
Accuracy
Time Base Crystal calibrated to ±2 ppm
Span Tempco ±1 ppm/°C (typ)
Long-term Drift ±5 ppm/year
Maximum Signal
Max applied voltage 600 Vac for 20, 200 and 300 V ranges, 125 Vac for other ranges
Overcurrent protection
25x for 2 mA, 8x for 20 mA, 2.5x for 200 mA, 1x for 5 A
Power Supply Boards (one required)
Voltage, standard 85-264 Vac or 90-300 Vdc
Voltage, optional 12-32 Vac or 10-48 Vdc
Frequency DC or 47-63 Hz
Power consumption 1.2W @ 120 Vac, 1.5W @ 240 Vac, 1.3W @ 10 Vdc, 1.4W @ 20 Vdc, 1.55W @ 30 Vdc, 1.8W @ 40 Vdc, 2.15W @ 48 Vdc (typical, base meter)
Power Isolation 250V rms working, 2.3 kV rms per 1 min test
Excitation Output (standard)
5 Vdc 5 Vdc ± 5%, 100 mA (jumper selectable)
10 Vdc 10 Vdc ± 5%, 120 mA (jumper selectable)
12 Vdc 12 Vdc ± 5%, 100 mA (jumper selectable)
24 Vdc 24 Vdc ± 5%, 50 mA (jumper selectable)
Output Isolation 50 Vdc from signal ground
Analog Output Boards (one optional)
Output levels 4-20 mA, 0-20 mA, 0-10V, -10 to +10V (jumper selectable)
4-20 mA, 0-20 mA, 0-10V (dual-output option)
Current compliance 2 mA at 10V ( > 5 kΩ load)
Voltage compliance 12V at 20 mA (< 600 Ω load)
Scaling Zero and full scale adjustable from -99999 to +99999
Resolution 16 bits (0.0015% of full scale)
Isolation 250V rms working, 2.3 kV rms per 1 min test
Relay Output Boards (one optional)
Dual magnetic relays 2 Form C, 10A max, 440Vac or 125Vdc max, 2500VA or 300W
Quad magnetic relays 4 Form A (NO), 10A max, 440Vac or 125Vdc max, 2500VA or 300W
Dual solid state relays 2 Form A (NO), AC or DC, 0V - 400V, 120Ma, 35Ohms (max at On-State)
Quad solid state relays 4 Form A (NO), AC or DC, 0V - 400V, 120Ma, 35Ohms (max at On-State)
Relay commons Isolated commons for dual relays or each pair of quad relays
Relay isolation 250V rms working, 2.3 kV rms per 1 minute test
Relay latching modes Latching or non-latching
Relay active modes Active on or off, active high or low
Hysteresis modes QA passband mode, split hysteresis, span hysteresis
Communication Boards (one optional)
Board selections RS232RS485 with dual RJ11 connectors, RS485 with dual RJ45 connectors, USB, Ethernet, USB-to-RS485 gatewayEthernet-to-RS485 gateway, WiFi with built-in antenna plus USB & RS485, WiFi with external antenna plus USB & RS485
Protocols Laurel Custom ASCII (serial), Modbus RTU (serial), Modbus TCP (Ethernet or WiFi)
Digital addresses 247 (Modbus), 31 (Laurel ASCII),
Isolation 250V rms working, 2.3 kV rms per 1 min test
Environmental
Operating temperature -40°C to 70°C (-40°F to 158°F)
Storage temperature. -40°C to 85°C (-40°F to 185°F)
Relative humidity 95% at 40°C, non-condensing
Protection NEMA-4X (IP-65) when panel mounted
Signal Connections
Pinout for Laureate Digital Timer Interval Meter and Digital Timer
Mechanical
Enclosure 1/8 DIN, high impact plastic, UL 94V-0, color: black
Mounting 1/8 DIN panel cutout required: 3.622" x 1.772" (92 mm x 45 mm).
Dimensions 4.68" x 2.45" x 5.64" (119 mm x 62 mm x 143 mm) (W x H x D)
Maximum panel thickness 4.5 mm (0.18")
Tightening Torque - Connectors Screw terminal connectors: 5 lb-in (0.56 Nm)
Tightening Torque - Pawls Digital Panel Meter Case Pawls: 5 lb-in (0.56 Nm)
Weight of base meter 210 g (7.4 oz) typical (DPM, counter, timer, 6-digit remote display)
Weight of option boards 30 g (1.0 oz) typical per board (analog output, relay output, communications)
General
Programming Methods Four front panel buttons or via Laurel's free Instrument Setup Software, which runs on a PC under MS Windows. 
Security Lockout options include using the front panel buttons, the free Instrument Setup Software, or a hardware jumper.
Warranty 3 years parts & labor
Recalibration: All ranges are calibrated at the factory. Recalibration is recommended every 12 months.

Free Instrument Setup Software for Series 2 Laureates

Digital Panel Meter Laurel Electronics Digital Transmitters
1/8 DIN Digital Panel Meters DIN Rail Transmitters

Free Downloadable Windows-based Instrument Setup (IS) software (Data Interface Board Required) for use with our programmable Digital Panel Meters, Scale Meters, Counters, Timers, Remote Displays, and Transmitters, are an easy method to set up Laureate 1/8 DIN digital panel meters, counters, timers, remote displays, and DIN-rail transmitters, as explained in the Instrument Setup Software Manual. Laureate 1/8 DIN instruments can also be set up from the front panel, as explained in their respective Owners Manuals. Instrument Setup software is of benefit whether or not the PC is connected to the instrument.

  • When the PC is connected to the instrument, Instrument Setup software can retrieve the setup file from the instrument or open a default setup file or previously saved setup file from disk View Setup, then provides graphical user interface (GUI) screens with pull-down menus applicable to input, display, scaling, filtering, alarms, communications, analog output, and front panel lockouts. Fields that are not applicable to the instrument as configured are either left out or grayed out. Clicking on any item will bring up a detailed Help screen for that item. After editing, the setup file can be downloaded, uploaded to the instrument, or saved to a disk. The same setup file can then be downloaded into multiple instruments.
  • When the PC is not connected to the instrument, the above GUI screens can be used to set up a virtual instrument. The setup file can then be saved to disk. Switching toView Menu then brings up a screen with the required front panel programming steps. This view can be printed out for use at the instrument site and to serve as a hard copy record.

    Download Free Instrument Setup Software


Installation

Set User Account Control (UAC) of MS Windows to "Never notifiy me" so that Instrument Setup Software can create directories. The UAC change screen can be reached as follows:

  • Under Windows 7, click on the Windows Start button in the lower left of the desktop and enter "UAC" in the search field.
  • Under Windows 8, navigate to Control Panel, then to the "User Accounts and Family Safety" section, and click on "Change User Account Control Settings."
  • Under Windows 10, click on the Windows Start button in the lower left of the desktop, then on "Settings", and enter "UAC" in the search field.
  • Reboot your computer for the changed UAC setting to take effect.
Meter board with USB Type-B connector

RJ11-to-DB9 cable with rear view of DB9 connector to PC

Laurel USB cable, P/N CBL05

RS232 cable, meter to PC, P/N CBL01

Laureate 1/8 DIN Laureate instruments must be equipped with a serial communications board and be connected to the computer via a serial communications cable. The connection can be via RS232, RS485, USB or Ethernet. Following setup, the serial communications board may be removed from the instrument if desired. The wiring of the RS232 cable is illustrated above with end views of the two connectors.

Laureate LT Series transmitters come standard with a 3-wire serial interface, which can be jumpered for RS232 or RS485.
Laureate LTE Series transmitters come standard with an Ethernet interface.

Meter Setup Screens

Click on any of the reduced screens below for a full-size screen view, then click on the Back button of your browser to return to this page. The screens examples below are for a fully-loaded Series 2 Digital Panel Meter (DPM), which is connected to the PC via RS232. If the meter is a Series 1 meter (pre-2007), this is sensed by the software, and somewhat different screens are brought up. Please see Series 1 setup screens.

Laurel Dual Channel Pulse Input Rate Meter
Welcome Screen
From the computer desktop, click on Start > Programs > IS2 > IS2. Or click on the IS icon on your desktop. This splash screen will be displayed for three seconds. The software revision number is in the lower right.
more
Setup Screen 02s for Digital Panel Meters and Digital Transmitters
Communications Selection Screen
Specify your desired communication protocol and the serial communications bus type, which should match the jumper setup of the instrument. Select None if the PC is not connected to the instrument.
more
Setup Screen 3 for Digital Panel Meters and Digital Transmitters
Establish Communications Screen
If you selected RS-232, you will be asked to specify the PC Com Port and Baud Rate, which should match the jumper setup of the instrument. Click on Establish. With the right settings, the Communications Established field will light up in green, and the Meter Type will be recognized. If so, click onMain Menu.
more
Setup Screen 4 for Digital Panel Meters and Digital Transmitters
Main Menu Screen
Click on File > Default Setup to retrieve the default setup file from disk for your type of meter. Click on File > Open Setupto retrieve a previously saved setup file from disk or on File > Save Setup to save your edited setup file to disk. Click onDPM > Get Setup to retrieve the setup file from your meter or on DPM > Put Setup to download your edited setup file into the meter.
more
Setup Screen 5 for Digital Panel Meters and Digital Transmitters
DPM Input + Display Setup Screen
From the Main Menu, click on View > Setup, then on theInput+Display tab. You can now specify the meter hardware, signal type, display mode, and functions of control inputs A and B. Clicking on any item brings up a pull-down menu with the available choices.
more
Setup Screen 6 for Digital Panel Meters and Digital Transmitters
DPM Scaling Setup Screen
Click on the Scaling tab, which provides three scaling methods to relate the signal to the displayed reading: 1) Scale and Offset method, 2) Coordinates of two points method, and 3) Reading Coordinates of Two Points method. The last method uses actual high and low signals, and the computer will prompt you.
more
Setup Screen 7 for Digital Panel Meters and Digital Transmitters
DPM Filter Setup Screen
Click on the Filter tab, which allows you to specify the digital filter time constant (if any), the adaptive filter threshold, and whether Peak / Valley values are filtered or unfiltered. As for all setup screens, clicking on the F1 key while an item is highlighted brings up a Help screen for that item, as illustrated.
more
Setup Screen 8 for Digital Panel Meters and Digital Transmitters
DPM Relay Alarms Setup Screen
Click on the Relay Alarms tab, which allows you to set up Alarms 1 and 2 for the optional dual relay output board. Clicking on any of the four numeric fields changes these to green and brings up a special field to enter the desired numeric value, which is tied to the displayed reading.
more
Setup Screen 9 for Digital Panel Meters and Digital Transmitters
DPM Communications Setup Screen
Click on the Communications tab so set up serial communications. In particular, you can special the Serial Protocol and the meter address if multiple meters are to be addressed on the same serial data line.
more
Setup Screen 10 for Digital Panel Meters and Digital Transmitters
DPM Analog Output Setup Screen
Click on the Analog Out tab so set up the optional analog output board. Three output ranges are selectable, the endpoints of which can be tied to user-specified High and Low readings.
more
Setup Screen 11 for Digital Panel Meters and Digital Transmitters
DPM Lockouts Setup Screen
Click on the Lockouts tab to check off menu items which will no longer be accessible from the front panel of the meter. This will simplify meter operation and prevent unintended setup changes.
more

Meter Setup Utilities

Setup Screen 12 for Digital Panel Meters and Digital Transmitters
DPM Front Panel Setup Screen
As an aid to programming the meter from the front panel when a serial connection is not available, you can return to the Main Menu and click on View > Menu. The required sequence of front panel screens will then be displayed. Click on any step in the sequence for the meaning of each digit, as illustrated for the FILtEr step. For a hardcopy, simply press on Print.
more
Setup Screen 13 for Digital Panel Meters and Digital Transmitters
DPM Jumper Setup Screen
Specify your desired communication protocol and the serial communications bus type, which should match the jumper setup of the instrument. Select None if the PC is not connected to the instrument.
more
Setup Screen 14 for Digital Panel Meters and Digital Transmitters
DPM Jumper Setup Screens
Click on any of the displayed plug-in boards, and you will be presented with the jumper positions and electrical connections for your selected board. This minimizes the need to refer to the printed manual.
more
Setup Screen 15 for Digital Panel Meters and Digital Transmitters
DPM Commands Screen
This page allows you set up external input, serial communications, an analog output proportional to the display (optional), and lockouts for Laureate digital counters. The grayed out area at the top right of the screen applies to Laureate remote displays.
more
Graphical Output Screens (not available with Ethernet)

From the Main Menu, click on Readings if your PC is connected to the meter. A pull-down menu then offers three choices: ListPlot and Graph.

  • List presents the latest readings in a 20-row by 10-column table. Press Pause at any time to freeze the display. This is one method to capture peak readings.   
  • Plot generates a plot of readings vs. time in seconds. It effectively turns the DPM-PC combination into a printing digital oscilloscope.
    more 
  • Graph generates a histogram where the horizontal axis is the reading and the vertical axis is the number of occurrences of readings. The display continually resizes itself as the number of readings increases.
    more
Setup Screen 18 for Digital Panel Meters and Digital Transmitters
DPM Calibration Screens
Click on the Scaling tab, which provides three scalClick on the Scaling tab, which provides three scaling methods to relate the signal to the displayed reading: 1) Scale and Offset method, 2) Coordinates of two points method, and 3) Reading Coordinates of Two Points method. The last method uses actual high and low signals, and the computer will prompt you.
more
Setup Screen 19 for Digital Panel Meters and Digital Transmitters
Frequency Meter Calibration Screen
Calibration of the quartz crystal of the Laureate frequency meter requires the input of a known frequency from a calibrator. Apply the frequency, then enter the frequency in Hertz. Calibration will be automatic, with storage of the calibration factor stored in non-volatile memory.
more

 

Laureate™ 1/8 DIN Case For Laureate Digital Panel Meters, Counters, Timers & Remote Displays

Laurel panel meter case

Key Features

  • Meets 1/8 DIN Standard.
  • Installs from front of panel.
  • Short depth behind the panel: only 4" (102 mm) plus connectors.
  • Understated 0.157" (4 mm) thick bezel.
  • Meets NEMA 4X (IP-65) for high-pressure wawshdon when panel mounted.
  • Screw clamps connectors meet VDE / IEC / UL / CSA safety standards.
  • Rugged GE Lexan® housing material.
  • Safety certified per EN 61010-1.
CE CertifiedRoHs CertifiedETL Certified

Dimensions

Mechanical specifications of Laureate digital panel meters and electronic counters

Maximum panel thickness: 4.5 mm (0.18")
Weight of base meter:
210 g (7.4 oz) typical (DPM, counter, timer, 6-digit remote display)
Weight of option boards: 30 g (1.0 oz) typical per board (analog output, relay output, communications)
Tightening Torque - Connectors: Screw terminal connectors: 5 lb-in (0.56 Nm)
Tightening Torque - Pawls: Digital Panel Meter Case Pawls: 5 lb-in (0.56 Nm)
Dimensioned CAD assembly drawings in EPRT, STEP, x_t. dwg, pdf file formats: Laureate-meter-case.zip (zipping prevents browser from opening CAD files as text files).

Panel Mounting

Mechanical Panel Mounting GuideSlide the meter into a 45 x 92 mm 1/8 DIN panel cutout. Ensure that the provided gasket is in place between the front of the panel and the back of the meter bezel. The meter is secured by two pawls, each held by a screw, as illustrated. Turning each screw counterclockwise extends the pawl outward from the case and behind the panel. Turning each screw clockwise further tightens it against the panel to secure the meter.

Turning each screw counterclockwise loosens the pawl and retracts it into its well. This position allows installed meter to be removed from their panel, or new meters to be installed in a panel. Do not remove the screws from their pawls. Doing so would cause the screw and pawl to fall off and likely get lost. Do not overtighten so as not to damage the plastic parts.

 

Time Interval Mode for Time Delay
Time Interval Mode for Time Delay For periodic pulses applied to A and B channels, time delays can be measured down to 0.2 µs resolution from the rising or falling edge of A to the rising or falling edge of B (selectable).
Time Interval Mode for Pulse Width
Time Interval Mode for Pulse Width The width of periodic pulses (t1 or t2) can be measured by tying the A and B channels together. As for time delay, readings are averaged over a user-selectable gate time.
Timing Process Dynamics with a Panel Meter and Time Interval Meter
Timing Process Dynamics with a Panel Meter and Time Interval Meter The start and stop pulses used for timing can be generated by the dual relay board in a Laureate panel meter or digital counter. For instance, the start and stop pulse edges can be created as temperature passes two alarm setpoints, or temperature cycles in a hysteresis control mode.
Rate Based on 1 / Time
Electronic Timer - Replacing an Oscilloscope with a Laureate Meter The Extended stopwatch meter can be programmed to display highly accurate rate based on elapsed time. A pulse or switch closure can initiate timing, while another pulse or switch closure stops timing. The meter can be programmed with multipliers to display rate in appropriate engineering units, such as meters/sec, for any time duration.
Replacing an Oscilloscope with a Laureate Time Interval Meter
Replacing an Oscilloscope with a Laureate Time Interval Meter An oscilloscope is great for viewing and timing pulses in a lab. However, in fixed installations where digital timing accuracy and control outputs are required, a low-cost Laureate time interval meter will be the instrument of choice. Resolution to 0.2 µs is feasible.
Instrumenting a Pulsed Laser System Using Laureate Counters
Instrumenting a Pulsed Laser System Using Laureate Counters
Some of the many possibilities in instrumenting a pulsed laser system with Laureate dual-channel counters.

 

 

CAL-Digital

Certificate of Calibration

$65.00

DLS-XLOG2

XLog2 Data logging Software

$495.00

IPC

Splashproof Cover

$55.00

CON01

CON01 Connector

$75.00

CBL01

RS232 Cable for Meters

$35.00

CBL02

USB-to-RS232 Adapter Cable

$47.00

CBL04

RS232 Cable for LT Transmitters

$47.00

CBL05

USB Data Cable for Meters

$47.00

CBL06

USB-to-RS485 Adapter Cable

$47.00

CBL07

USB Programming & Data Cable

$47.00

CBL08

RS485 Splitter Cable

$33.00

CBL6

6-foot Power Cable

$41.00

CBL12

12-foot Power Cable

$47.00

Modular Design for Maximum Flexibility at Minimum Cost

All boards are isolated from meter and power grounds. Optional Plug-in-Play boards for communications and control include Ethernet, WiFi, serial communication boardsdual or quad relay boards, and an analog output board. Laureates may be powered from 85-264 Vac or optionally from 12-32 Vac or 10-48 Vdc. The display is available with bright red or green 0.56" (14.2mm) high LED digits. The 1/8 DIN case meets NEMA 4X (IP65) specifications from the front when panel mounted. Any setup functions and front panel keys can be locked out for simplified usage and security. A built-in 5, 10, 12, or 24 Vdc excitation supply can power transducers, eliminating the need for an external power supply. All power and signal connections are via UL / VDE / CSA rated screw clamp plugs.

The Laureate™ Series features modular design with up to 7 isolated plug-in boards, applicable to all Laureate 1/8 DIN Panel Meters.

Schematic for Digital Panel Meter

Modular Hardware

The design of the Laureate™ Series is modular for maximum flexibility at minimum cost. All boards are isolated from meter and power grounds. The base configuration for panel meters or counter consists of a main module (with computer and plug-in display boards), a power supply board, and a signal conditioner board. Optional plug-in-play boards include an isolated setpoint controller board, an isolated analog output board, and an isolated digital interface board. Modular design and a choice of plug-in options allow the Laureate to be customized for a broad range of applications from simple monitoring to control and computer interface. There can be up to five plug-in boards in a 1/8 DIN Laureate.

Dual Board sets

Connecting Laureate Panel Meters to a Local Area Network (LAN)

Up to 30 Laureate Panel Meters and/or LT Transmitters can be configured for RS485 and daisy-chained to an LT Transmitter using Laurel’s High Speed Ethernet-to-RS485 converter board for seamless LAN integration. Alternatively, Laurel LTE series Ethernet transmitters can connect directly to a LAN via an Ethernet cable. Setup for both configurations is streamlined using Laurel’s free Instrument Setup Software, which simplifies node discovery and transmitter configuration.

Flexible Communication Options for Panel Meters

Laureate Panel Meters can be equipped with Laurel communication boards to support various interfaces and protocols. These include serial interfaces with ASCII or Modbus RTU protocols, and Ethernet interfaces with web access, ASCII, or Modbus TCP/IP protocols, ensuring versatile connectivity for your commercial applications.

Laurel network with Ethernet-to-analog converter board

Ordering Guide
Part Number as Configured: L8110EFR
Price as Configured: $711.00

Click on the Option Board Links for More Product Information

Base Item
$169.00
Display Color
$0.00
$0.00
$41.00
$41.00
Power (Isolated) $75.00
$115.00
Relay Output (Isolated)
$0.00
$101.00
$70.00
$128.00
$96.00
Analog Output (Isolated)
$0.00
$115.00
$172.00
Data Interface (Isolated)
$0.00
$81.00
$109.00
$135.00
$81.00
$135.00
$237.00
$259.00
$182.00
$204.00
$171.00
$193.00
$204.00
$226.00
Signal Input (Isolated)
$81.00
Part Number as Configured:
L8110EFR
Price as Configured:
$711.00
Quantity:
- +
Extended Price:
$711.00

Understanding the Laureate™ 1/8 DIN Panel Meters for A-to-B Time Interval

The Laureate™ 1/8 DIN Panel Meters for A-to-B Time Interval can display pulse width or time delay between individual pulses to a resolution of 0.2 µs, or the average pulse width or average time delay between multiple pulses. Timing starts when a pulse is applied to Channel A (selectable positive or negative edge) and ends when a pulse is applied to Channel B (selectable positive or negative edge). For a single pulsed signal, the A and B inputs can be tied together — a positive or negative slope starts timing, and the opposite slope must stop it.

Timing Technique and Averaging

Timing is achieved by counting 5.5 MHz clock pulses. Multiple integral time intervals are averaged over a gate time selectable from 10 ms to 199.99 s, which also controls the display update time. Periodic timing interval is gate time plus 30 ms plus 0-2 time intervals. Time Before Zero Output is separately selectable from 10 ms to 199.99 s.

Display Resolution by Range

Time interval displays in seconds, milliseconds, or microseconds with 6-digit resolution: 1 ms resolution from 0-199.999s, 100 µs from 0-99.9999s, 10 µs from 0-9.99999s, 1 µs from 0-0.999999s, and 0.2 µs from 0-0.099999s. For times under 100 ms, resolution down to 0.2 µs can be achieved by applying a multiplier of 10, moving the decimal point one position, and averaging many time intervals.

Rate Based on 1/Time (Extended Only)

Highly accurate rate can be displayed by taking the inverse of time, with extensive arithmetic capabilities for engineering-unit display such as meters/sec. A pulse or switch closure initiates timing, another stops it, and multipliers scale the result to appropriate units for any time duration.

Real-World Applications

  • Time Delay Measurement — for periodic pulses on A and B channels, time delays are measured down to 0.2 µs resolution from the rising or falling edge of A to the rising or falling edge of B (selectable).
  • Pulse Width Measurement — the width of periodic pulses is measured by tying A and B channels together, with readings averaged over a user-selectable gate time.
  • Timing Process Dynamics — start/stop pulses generated by a dual relay board as a process variable passes two alarm setpoints or cycles in hysteresis control mode.
  • Replacing an Oscilloscope — for fixed installations needing digital timing accuracy and control outputs rather than lab-bench viewing, a low-cost time interval meter with 0.2 µs resolution is the instrument of choice.
  • Instrumenting a Pulsed Laser System — dual-channel counters provide elapsed time, pulse count, pulse width, pulse separation, duty cycle, and pulse repetition rate.

Factory-Calibrated Accuracy

Time base is crystal-calibrated to ±2 ppm, with ±1 ppm/°C span tempco and ±5 ppm/year long-term drift. Factory recalibration is recommended annually.

Where Time Interval Panel Meters Are Used

  • Laser & Photonics Pulse Characterization — width, separation, and repetition rate measurement for pulsed laser systems.
  • Delay Line & Propagation Timing — precise start-to-stop delay measurement between two independent trigger sources.
  • Test Bench Replacement for Oscilloscopes — permanent, fixed-installation digital timing with control outputs.
  • Process Dwell & Setpoint-Crossing Timing — interval measurement tied to relay-generated start/stop events.
  • PWM & Pulse Width Verification — tied-channel pulse width measurement for signal quality checks.
  • High-Speed Component Response Testing — relay, solenoid, and valve actuation-to-response timing.
  • Rate-from-Time Velocity Measurement — inverse-time rate display for photodetector or switch-triggered speed sensing.

Time Interval Panel Meter Frequently Asked Questions

Why does the periodic timing interval formula include "0-2 time intervals" as a variable addition, rather than a fixed value?

This reflects the meter's need to complete at least one full, valid measurement cycle within the gate time window — since the timing interval being measured doesn't necessarily align perfectly with the start and end of the gate time, the meter may need to wait for up to two additional complete time intervals beyond the nominal gate time to ensure a complete, valid averaged reading before reporting the result.

How does the ×10 multiplier trick actually achieve 0.2 µs resolution for signals under 100 ms?

Documented guidance specifically describes applying a multiplier of 10 and moving the decimal point one position, combined with averaging many time intervals — this effectively displays a scaled, more finely resolved version of the underlying measurement by leveraging the averaging process across many cycles, extracting resolution finer than what a single raw measurement at that range would otherwise show on the display.

Does averaging multiple time intervals over a longer gate time improve accuracy, or just display stability?

Both, to different degrees — a longer gate time averaging more individual timing intervals reduces the random variation between individual readings (statistical averaging), which both stabilizes the displayed value and, for a genuinely stable and repetitive input signal, converges the average closer to the signal's true underlying interval, though it doesn't correct for systematic errors like a fixed trigger-level offset.

What's the difference between the "Time Before Zero Output" setting and the gate time setting?

Gate time controls how long the meter averages and how often it updates its reading, while Time Before Zero Output is documented as a separately selectable setting used specifically to indicate loss of signal — if no valid new pulse arrives within that configured window, the meter zeroes its output rather than continuing to display a stale prior reading indefinitely.

Can the same meter measure both a fixed delay between two separate signals and the pulse width of a single signal, or does it need reconfiguring for each?

Both modes are documented as available on the same hardware — the A-to-B delay measurement uses Channel A and Channel B connected to genuinely separate signals, while the pulse-width mode simply ties both channels to the same single signal — switching between these is a wiring and setup configuration change rather than requiring different hardware.

Why does the rate-based-on-1/time mode specifically require the Extended main board rather than being available on the Standard version?

Computing rate as the mathematical inverse of a measured time, along with the documented "extensive arithmetic capabilities" needed to scale that result into arbitrary engineering units, requires processing capability beyond simply displaying the raw timed interval — this is documented specifically as an Extended-board capability, consistent with the Extended board generally offering additional computational functions across the Laureate counter product line.

Does the laser instrumentation application's six listed parameters (elapsed time, pulse count, width, separation, duty cycle, rep rate) all come from reading the same physical pulse train?

Yes, potentially — the documented application specifically describes "some of the many possibilities" achievable from the same pulsed laser signal using dual-channel counters, meaning the underlying physical signal is the same across these measurements, though achieving several parameters truly simultaneously would typically mean configuring separate meters or channels, each set up for its own specific parameter, rather than one single reading yielding all six.

Is the maximum applied voltage rating the same across all input ranges, or does it vary by range like the resolution does?

It varies — documented specifications show maximum applied voltage at 600 Vac specifically for the 20V, 200V, and 300V ranges, but only 125 Vac for other ranges, alongside overcurrent protection that also varies by range (25x for 2 mA, 8x for 20 mA, 2.5x for 200 mA, 1x for 5A) — confirming the specific range in use against its own voltage and overcurrent rating matters rather than assuming one blanket protection level across all ranges.

Does choosing to display time interval in seconds versus milliseconds versus microseconds change the underlying measurement, or just the displayed units?

Just the displayed units and associated resolution — the underlying measurement is always based on the same 5.5 MHz clock counting technique, and the documented range-dependent resolution table (1 ms down to 0.2 µs) shows the display simply presents that same underlying count at whatever unit and decimal scaling is appropriate for the selected range, not a fundamentally different measurement process.

Can the A-to-B time interval mode measure a negative delay, where the Channel B pulse actually arrives before the Channel A pulse?

The documented timing mechanism specifically starts on a Channel A edge and stops on a Channel B edge — it's built around measuring the interval from a defined start event to a defined stop event, not around determining which of two independent, unordered pulses arrived first. An application where the physical B-triggering event could genuinely precede the A-triggering event would need the channels wired so that whichever event is expected to

Trigger-Level Timing Error & Slew Rate Questions From the Field

What is "trigger level timing error," and why does it matter for time interval measurements?

Documented metrology guidance specifically defines this as the timing uncertainty introduced when a signal's actual level at the moment of crossing the trigger threshold isn't perfectly known — because real trigger circuits have some uncertainty in the exact threshold voltage, and this voltage uncertainty translates into a timing uncertainty whose magnitude depends on how fast the signal is changing (its slew rate) at the trigger point.

How is trigger level timing error mathematically related to a signal's slew rate?

Documented formulas specifically express this relationship directly: timing error equals trigger level voltage error divided by the signal's slew rate at the trigger point — meaning for a fixed amount of trigger-level voltage uncertainty, a signal with a steeper (faster) slew rate at the crossing point produces proportionally less timing error than the same voltage uncertainty applied to a slower-rising or slower-falling signal.

Why is a square wave documented as having essentially zero trigger-level timing error compared to a sine wave?

A square wave's edges are documented as approaching infinite slew rate at the trigger crossing point, and since timing error is inversely proportional to slew rate, an infinitely fast transition drives the resulting timing error toward zero — a slower-transitioning signal like a sine wave crossing the same trigger threshold takes measurably longer to traverse the same voltage uncertainty band, producing a correspondingly larger timing error.

Does using a more sensitive trigger input setting always improve timing accuracy?

No — documented guidance specifically warns that increasing input circuit sensitivity can make trigger error worse rather than better, because a more sensitive threshold detector also becomes more susceptible to noise on the incoming signal causing the trigger point to fire too early or too late, which is a genuinely different error source (noise-driven trigger error) than the systematic trigger-level timing error tied to slew rate.

What's the documented difference between a "systematic" timing error and a "random" or noise-driven trigger error?

Documented distinctions specifically separate these: systematic error arises from consistent mismatches between measurement channels (such as differing rise/fall times or propagation delays between a start and stop channel), producing a repeatable offset that can potentially be calibrated out, while trigger/noise error is driven by genuinely random noise on the input signal and can't be removed through simple calibration since it varies unpredictably from measurement to measurement.

Is there a practical way to minimize trigger-level timing error without changing the input signal itself?

Yes — documented guidance specifically recommends triggering at the signal's offset value (the point of highest slew rate for a sine or square wave) specifically to minimize this error, and further notes that measuring from offset-to-offset (a full period or 0-degree phase reference between two signals) can cause hysteresis-window-related errors to cancel out, both being practical trigger-point choices rather than hardware changes.

Does averaging many time interval readings correct for trigger-level timing error the way it reduces random noise?

Not necessarily — documented distinctions specifically note that trigger-level timing error tied to slew rate is a systematic effect (the same bias applies consistently at a given trigger level and slew rate), so unlike genuinely random measurement noise, straightforward averaging across many readings won't cancel out a systematic trigger-level bias, since it's not actually random from measurement to measurement.

Do mismatched cable lengths or probe impedances between a start channel and stop channel genuinely introduce measurable timing error?

Yes — documented analysis specifically identifies mismatched probes, cables of differing length, and impedance mismatches between start and stop paths as real contributors to systematic timing error, with documented estimates showing meaningfully different error magnitudes depending on signal slew rate (a documented example shows roughly 70 ps of error for a slow-rising pulse versus only about 7 ps for a fast-rising pulse from the same impedance mismatch) — confirming matched cabling and impedances between channels genuinely matters for measurement accuracy.