MAGNA Series Large Digit Displays for Meters, Counters, Clocks, and Timers
Features
- Choice of 2-1/4", 4", 6" or 8" digit heights
- Choice of 4 or 6 digits with period or color dividers
- Choice of normal or outside viewing brightness
- Choice of signal inputs and functions
- Choice of panel mount, wall mount or suspension mount
- Choice of 95-264 Vac or 11-30 Vdc power
- Sealed to NEMA-4 (IP65)
- Only 3.0" (75 mm) deep
- Programmable from front panel
- Optional two or four 2A relay outputs, analog output, serial I/O
Four digit heights are available a standard: 57 mm (2-1/4"), 102 mm (4.0"), 150 mm (5.9"), and 200 mm (7.9"). Solid segments are used for normal brightness 2.2" and 4.0" digits. Individual 5 mm LED pixels are used for larger digits and outdoor brightness versions. The number of digits can be 4, 6 or 8, depending on the display function.
Indoor or outdoor viewing: MAGNA Series Displays with normal brightness LEDs can be read over a machine or across a plant floor. Displays with outdoor brightness LEDs can be read across an industrial yard, parking lot or roadway, for example to display vehicle load. A heater option allows outdoor operation in winter in cold climates. Available mounting options are panel mount, wall mount and suspension mount. Environmental sealing to IP65 (NEMA-4X) is standard.
Choice of signal inputs: MAGNA Series Displays are available for different signal types, with can each be associated with 4 or 6 digits. Please click on the links below for detailed information by signal type:
- Serial data from PCs, PLCs, serial output transmitters, and smart sensors.
- Process input (e.g., 4-20 mA)
- Strain gauge / load cell input
- Temperature input, Pt100 RTD or thermocouple
- Pulse input for frequency or rate
- Pulse input for total or quadrature position
- Pulse input for operation as a clock or timer
Intuitive setup is normally provided by means of built-in front panel switches, which can be locked. It is also possible to remotely wire four pushbuttons to the display.
MAGNA units are built to order. MAGNA orders are non-cancelable and non-returnable.
Customized large digit displays are available by special quotation:
- LED colors green, blue, white,yellow (not just red).
- Digit heights of 12", 16", 24" or 32" (not just4", 6" or 8").
- 2 or 4 solid state relays (not just mechanical relays).
- Stainless steel housing (for food processing and pharmaceutical industries).
- Explosion-proof stainless steel housing rated for ATEX Zones 2 and 22 (equivalent to Class1 / Div 2).
- Custom signs with different colors, with fixed captions, and with multiple numeric display windows.



| Serial Data Input | |
|---|---|
| Serial Data Types | RS232 or RS485 (specify at time of order) |
| Serial Connector | Detachable plug-in screw terminals |
| Displayed Information | ASCII: Displays any character within 7-segment display limitations. Quant: Displays only numeric ASCII values. |
| Qa.Tot: Quantity totalizer. Can be used to accumulate weight values, for example after each batch. Uses a contact closure to trigger addition. | |
| Baud Rate | 300 to 115200 baud |
| Data Format | 701, 7e1, 7n2, 801, 8e1, 8n1, 8n2 |
| Termination Character | Hex 00 to FF |
| Reject Characters | Counted from termination character |
| Addressing | 00 (wildcard) to F7 |
| Process Signal Input | |
| A/D Converter | 20-bit resolution |
| Current Signal Types | 0-10 mA, 0-20 mA, 4-20 mA with 33Ω input resistance |
| Voltage Signal Types | 0-5V, 1-5V, 0-10V with 1 MΩ input resistance |
| Accuracy | ± 0.05% of range. |
| Tempco, Scale | ± 25 ppm/°C |
| Tempco, Offset | ± 30 ppm/°C |
| Excitation | 24 Vdc up to 40 mA, or ratiometric 0-10V for slide-wire |
| Strain Gauge / Load Cell Input | |
| A/D Converter | 20-bit resolution |
| Signal Gain | Suitable for 0.5 mV / V to 4 mV / V load cells |
| Accuracy | ± 0.05% of range. |
| Tempco, Scale | ± 25 ppm/°C |
| Tempco, Offset | ± 30 ppm/°C |
| Excitation Output | Isolated 10V up to 120 mA to power up to four 350Ω load cells in parallel |
| Pulse Input for Frequency, Rate, Total | |
| Number of Inputs | 4 |
| Signal Types | Configurable for contact closures, NPN or PNP proximity switches, 5V logic pulses, 24V pulses, quadrature |
| Debounce | Programmable to eliminate false counting from contact bounce. |
| Timing Reference | Temperature-controlled quartz crystal. |
| Pulse Input for Clock Operation | |
| Time Reference | Precision, temperature-compensated quartz crystal. |
| Clock Format | HH:MM or HH:MM:SS |
| Display | |
| Number of Digits | 4 or 6 |
| Digit Height | 57 mm (2-1/4"), 102 mm (4.0"), 150 mm (5.9"), or 200 mm (7.9") |
| Digit Color | Red |
| Brightness | Variable |
| Brightness | 8.8.8.8. or 8.8.8.8.8.8. (standard) |
| Clock Format | HH:MM or HH:MM:SS (optional, specify at time of order) |
| User Controls | |
| Scaling | Digital direct or theoretical scaling with scale & offset. |
| Filtering | Digital filtering, time constants adjustable from 0 to 25 sec. |
| Rounding | Selectable last-digit rounding of 1, 2, 5, 10, 20, 50 units. |
| Linearization | Up to 10 points, direct or theoretical calibration. |
| Logic Inputs | |
| Font Panel Controls | Calibration, Tare, Reset, Max/Min, Alarms |
| Logic Functions | Three logic inputs, individually configurable for Hold, Reset, Tare, Peak / Valley, Net/Gross, Memory Address. |
| Logic Levels | Normally open, NPN or contact closure input to activate. 5V open circuit, 1 mA switched current. |
| Power | |
| AC Power (standard) | 100-240 Vac |
| DC Power (option) | 11-30 Vdc |
| Max Consumption | 30 VA |
| Analog Output Option | |
| Output Levels | 0-20/4-20 mA into 0 to 500Ω, 0.4 μA resolution. 0-10V into loads > 600Ω, 0.2 mV resolution. -10 to +10V into loads > 600Ω, 0.4 mV resolution. |
| Resolution | 16 bits |
| Accuracy | 0.1% of range |
| Stability | 50 ppm/°Cl |
| Output Isolation | Isolated from input and power |
| Scaling | Digitally scalable |
| Special Features | Can be set to operate from net or gross value. |
| Alarm Output Option | |
| Relay Type | Two or four relays rated 2A, 250VAC, SPDT |
| Special Features | Adjustable hysteresis |
| In-flight compensation facility. | |
| Energize or de-energize on trip. | |
| Adjustable timers to set energize and de-energize delays. Can also be set to pulse for applications needing less than 100% duty cycle. | |
| In-band and out-of-band alarm function. | |
| Manual and automatic in-flight compensation. | |
| Can be set to operate from net or gross value. | |
| Serial Data Output Option | |
| Output Types | RS232 or RS485, addressable, on demand or continuous output. |
| Special Features | Can include time and date with RTC option fitted. Can be set to operate from net or gross value. |
| Environmental | |
| Storage Temp. | -20°C to +70°C |
| Operating Temp. | 0°C to 50°C, non-condensing. -25°C to 50°C, non-condensing, with MHTR AC heater option. |
| Sealing | IP65 (NEMA-4) standard, all-round |
| Connections | M12 compression glands for round cable, diameter 3.0 to 6.5 mm (0.118" to 0.256") |
| Mounting | Wall mount, suspension mount, panel mount |
| Approvals | |
| Types | Produced to IPC 610 Class 2 Standard |
| UL ISO9001:2008 QA | |
Number of Digits & Case Dimensions

| Serial Data Input | 4 Digits | 6 Digits |
|---|---|---|
| Serial Data Input | ![]() |
![]() |
| Process, Strain Gauge, Rate / Frequency, Totalizer, Quadrature |
![]() |
![]() |
| Clock / Timer | ![]() |
![]() |
| Digit Height | Case Width x Height | Case Width x Height |
| 57 mm (2.2") | 280 x 155 mm (11.0" x 6.1") | 376 x 155 mm (14.8" x 6.1") |
| 102 mm (4.0") | 434 x 196 mm (16.7" x 7.7") | 616 x 196 mm (24.3" x 7.7") |
| 150 mm (5.9") | 580 x 247 mm (22.8" x 9.8") | 820 x 247 mm (32.3" x 9.8") |
| 200 mm (7.9") | 750 x 290 mm (29.5" x 11.4") | 1072 x 290 mm (42.2" x 11.4") |
| Case depth | 75 mm (3.0") | |
| Note: | Models with 57 mm (2.2") digits, 4 digits and 4 relays require the larger 6-digit case. For panel mount versions, add 18 mm (0.7") to case width and height for bezel and 25 mm (1.0") for cable gland in back of case. |
Number of Digits & Case Dimensions

| Serial Data Input | 4 Digits | 6 Digits |
|---|---|---|
| Serial Data Input | ![]() |
![]() |
| Process, Strain Gauge, Rate / Frequency, Totalizer, Quadrature |
![]() |
![]() |
| Clock / Timer | ![]() |
![]() |
| Digit Height | Case Width x Height | Case Width x Height |
| 57 mm (2.2") | 280 x 155 mm (11.0" x 6.1") | 376 x 155 mm (14.8" x 6.1") |
| 102 mm (4.0") | 434 x 196 mm (16.7" x 7.7") | 616 x 196 mm (24.3" x 7.7") |
| 150 mm (5.9") | 580 x 247 mm (22.8" x 9.8") | 820 x 247 mm (32.3" x 9.8") |
| 200 mm (7.9") | 750 x 290 mm (29.5" x 11.4") | 1072 x 290 mm (42.2" x 11.4") |
| Case depth | 75 mm (3.0") | |
| Note: | Models with 57 mm (2.2") digits, 4 digits and 4 relays require the larger 6-digit case. For panel mount versions, add 18 mm (0.7") to case width and height for bezel and 25 mm (1.0") for cable gland in back of case. |
MAGNA Large Digit Displays
- MAGNA Process Signal (4-20 mA, 0-10V) Input Manual: 45 pages, 0.5 MB
- MAGNA Clock-Timer Manual: 31 pages, 0.4 MB
- MAGNA Strain Gauge & Load Cell Input Manual: 45 pages, 0.5 MB
- MAGNA RS232 & RS485 Data Serial Data Input Manual: 36 pages, 0.4 MB
- MAGNA Totalizer & Rate Meter Manual: 47 pages, 0.5 MB
- MAGNA Thermocouple & RTD Input Manual: 45 pages, 0.5 MB
- MAGNA Alarm Options Manual: 32 pages, 0.25 MB
- MAGNA Analog Output Options Manual: 12 pages, 0.1 MB
- MAGNA Serial Output Options Manual: 18 pages, 0.2 MB